Download presentation
1
NFS System Components & Installation
2
Noti-Fire-Net NCS SLC L3 ~ L10 RDP Up to 32 4 Set On Board Relay O/P
SLC L2: Det.159 Mod. 159 RFX 4 Set On Board Relay O/P SLC L1: Det.159 Mod. 159 Up to 96 Programmable Input or Output EIA 485 Noti-Fire-Net EIA 232 NCS
3
CPU-3030 Note Display location
Note Display Connectors: Keyboard, LCD, Backlight Note Memory Battery shipped with protector in place. Remove prior to applying power. Note Auxiliary LED’s for Displayless Node Operation Note LED4 (STATUS) is for factory use only. Note Auxiliary Control Switches for Displayless Node Operation Note Main Power Supply (AMPS-24) harness connector Note Auxiliary Power Connector (1.0 A) Note LCM Ribbon Cable (p/n 75565) connector Note Conventional Module Ribbon Cable (p/n 71088) connectors Note Relays Note Supervisory and Security to Alarm switches Note EIA-485 Connectors – ACS, Terminal Note: Currently there are no listed terminal Annunciators for the 3030 Note EIA-232 Connectors for PRN Series or Keltron Printers Note: CRT terminal is not listed for the NFS-3030 Note Supervisory Connectors for Security Tamper and Auxiliary Power Supply Note NUP Connector for Network Operations and/or Programming
4
Display Note 640 character display (16 rows, 40 characters per row)
2 3 4 5 6 7 8 9 Q W E R T Y U I O P A S D F G H J K L Lower Case Z X C V B N M Space Esc Enter * # & / + - ( ) POWER FIRE ALARM PRE-ALARM SECURITY SUPERVISORY SYSTEM TROUBLE OTHER EVENT SIGNALS SILENCED POINT DISABLED CPU FAILURE SCROLL DISPLAY OTHER EVENT SIGNAL SILENCE DRILL HOLD 2 SEC. RESET DISABLE ENABLE PRINT SCREEN LAMP TEST F1 NEXT SELECTION PREVIOUS RECALL LAST ENTRY INCREMENT NUMBER Note 640 character display (16 rows, 40 characters per row) Note Status LEDs Note fixed keys Note Soft keys will have functions reassigned with each screen. Note QWERTY Keypad Note Function Keys Note: Disable/Enable and F1 keys have no function in the current software version.
5
Loop Modules J3 J1 J2 JP1 D33 +5V D32 D28 B+ A+ B- A- SLC JP2 TB1 JP3 SW1 EG FAULT Note each Loop may be designated for Style 4 or Style 6 operation Note each Loop may have devices programmed for CLIP or FLASH operation. If Modules are selected for CLIP, Rapid Polling must be enabled to ensure correct response time of Manual Stations (require addresses 01-20) Note J1 LCM Connector Cable (p/n 75655) input Note J3 LCM Connector Cable output Note J2 LCM & J1 LEM Connector plugs LEM mounts behind LCM and assumes the sequential Loop Address Note Loop Address selector switch Note Ground Fault LEDs D28 (lower) LCM, D32 (upper) LEM LCM-320 LEM-320
6
LCM Cables Note Lower Connection of each LCM is the Input Connector
7
LCM/LEM SLC Connector Typical Style 6.0/7.0 Typical Style 4.0
Channel B Channel A Channel A Return Channel B Output Wiring distance per channel (style 4)or per loop (style 6 or 7) not to exceed 12,500 ft. Resistance not to exceed 50 Ohms In Style 4, both channel A and B may be used.
8
AMPS-24(E) Power Supply TB1 HOT NEUTRAL EARTH SLCA SLCB +5V +24V COM ACCESSORIES TB6 24V PANEL +485 -485 GND 24V TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SW2 0 SW3 5 ON LED9 LED8 LED10 LED1 LED2 LED3 LED4 LED6 LED5 LED7 Note TB3 AC Connection 110/120 VAC, 50/60 Hz, 4.5A; AMPS-24E 240 VAC, 50/60 Hz, 2.25A Note TB1 SLC connection. AMPS supervised by 4 sequential SLC addresses. Use Type ID “POWER MONITOR” Note TB2 Panel Output provides 24 & 5 volt outputs to CPU via Cable p/n Maximum output 4.5A when TB6 not used; 3.2A if both outputs on TB6 used Note TB6 Auxiliary output. Use Power Harness Cable p/n for connection to AMG-1, FFT-7 or UZC-256. Maximum outputs: 24 VDC 1A; 5 VDC 1A Note TB4/TB5 Battery Connectors. Charging size AH, charging current 2.0A or 5.0A set by selector switch SW4 (partially covered by metal case). Note Battery Fuse F2 3AB 10A Note Address Select Switches SW2 (rotary decade) SW3 (base slide). Base address functions are XX0-XX3 or XX5-XX8, where XX = rotary setting. Rotary 0, Slide 0 is not acceptable. Note Configuration Switch SW1. Switches 1 & 2 must be on for UL listing of Switches 3 to 7 are factory set. Switch 8 enables the battery charger.
9
AMPS-24(E) Power Supply 120 @ 4.5A / 240 VAC @2.25 A GROUND FAULT (Y)
TB1 HOT NEUTRAL EARTH SLCA SLCB +5V +24V COM ACCESSORIES TB6 24V PANEL +485 -485 GND 24V TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SW2 0 SW3 5 ON LED9 LED8 LED10 LED1 LED2 LED3 LED4 LED6 LED5 LED7 GROUND FAULT (Y) TB6 Output (G) 24 V Output (G) SLC Address Switch Battery 24 25 ~ 200 AH Setting Switch Status LEDS LED1 Green – AC. Steady – AC Normal; Blink – AC Fail Delay LED2 Yellow – Battery or charger trouble LED4 Yellow – Trouble. 1 blink & pause = AC Fail; 2 blinks & pause = Internal PS Fail; 3 blinks & pause = Incorrect SLC address; 5 blinks & pause = Charger Shutdown; 6 blinks & pause = Accessory Power (TB6) overload; Steady = Panel Output overload/Accessories Output shut off. LED5 Green – SLCRXA. Blinks when data is received from SLC LED6 Yellow – UCFAILURE. Steady if AMPS Microprocessor fails LED7 Green – SLCTXA. Blinks when data is transmitted to SLC LED8 Green – ACCESSORIES. Steady for Normal TB6 output. Off during overload LED9 Yellow – GND FLT. Steady for Ground on any output or battery lead LED10 Green – 24VPANEL. Steady when TB2 is active. Off during overload 10 A Battery FUSE LED 1 : AC POWER (G) LED 2 : BATT / CHARGE TROUBLE (Y) LED 3: NOT USED LED 4 : TROUBLE (Y) LED 5 : SLCRXA (G) LED 6 : MICROPROCESSOR FAIL (Y) LED 7: SLCTXA (G) LED 4 : TROUBLE (Y)
10
Auxiliary Power APS-6R CHG-120
11
ACS Annunciators A1P1 A1P2 A1P3 A1P4 ACM(AEM)-24AT ACM (AEM) – 48 A
12
Repeaters RPT-W RPT- F RPT-WF Extend Distance 4000 ft (wire)
8 dB attenuation (fiber) Regenerate signal Support up to 32 receiving units Isolate signal Allow use of multiple remote power supplies RPT-W RPT- F RPT-WF
13
LCD-160 Remote Display
14
ACS Annunciators LCD-80 (ACS Mode Only) ACM-8R LDM-32 series
NOTIFIER REMOTE LCD ANNUNCIATOR ALL SYSTEMS NORMAL 12:10P 01/11/01 Hold for Status Contrast Adjust Lamp Test Ack/ Step Signal Silence System Reset 1 2 3 4 5 7 9 8 6 LCD-80 only operates in ACS mode on the It requires 1-4 consecutive 64PT ACS addresses in programming. ACM-8R and LDM series annunciators are defined as 64PT ACS devices LCD-80 (ACS Mode Only) ACM-8R LDM-32 series
15
ACS Annunciators Switch Group 5 Group 6 Group 7 Group 8 Group 1
All Auto Manual Acknowledge The SCS-8 is defined as a 64PT FSCS device. Points 1-64 allow assignment of individual Monitor and Control Modules for smoke control. Points provide “monitor” addresses for FCSC mode shutdown command. The UZC-256 takes 1-4 consecutive 64PT ACS addresses
16
Voice Components LOCAL SPEAKER VOLUME ALL CALL AUDIO LEVEL ALL CALL ON LINE TROUBLE AUDIO MESSAGE GENERATOR FIRE FIGHTERS TELEPHONE PAGE MODE AMG PAGE ON LINE LINE TROUBLE PHONE AMG address assignment (AMG-1/AMG-E), (AMG-X4). Each AMG is defined as a 64PT ACS device. Requires AMC-16AT/24AT at address 01 to activate tone/message functions. The FFT-7 is only supervised by an AMG at address 32
17
Page 19 DR-A4 SBB-A4 The assembly consists of a back box and a locking door with two keys. The back box and door can be ordered separately or as a complete unit. Doors may be hinged right or left. A semi-flush trim ring kit is available for each box size. 32 41
18
Page 19 DR-B4 SBB-B4 42
19
Page 20 DR-C4 SBB-C4 43
20
Page 20 DR-D4 SBB-D4 33 44
21
ABS-2D ABS-4D
22