Presentation is loading. Please wait.

Presentation is loading. Please wait.

Soft X-Ray Diagnostic System for HT-7 and EAST Tokamaks

Similar presentations


Presentation on theme: "Soft X-Ray Diagnostic System for HT-7 and EAST Tokamaks"— Presentation transcript:

1 Soft X-Ray Diagnostic System for HT-7 and EAST Tokamaks
ASIPP Soft X-Ray Diagnostic System for HT-7 and EAST Tokamaks LIQUN HU

2 Physical features of the diagnostic
HT-7 ASIPP Physical features of the diagnostic ISXR Ne, Te, Zeff A chord-integrated measurement—point measurement, high resolution in space and high temporal response in time to the variations happened inside of the plasma. The intensity distribution and evolution and tomography of SXR radiation information on the plasma structure, MHD instability, sawtooth instability, phenomena occurring during major disruptions, heat pulse propagation transport et al.

3 SXR Array Diagnostic Features in HT-7
ASIPP SXR Array Diagnostic Features in HT-7 Two multi-channel arrays, 37 detectors of rectangular Au-Si SBDs with active area of 320 mm2, a pinhole camera like Vertical array with 37 detectors of SBDs Horizontal array with Slot-aperture with a movable slider covered with Be foils Au-Si detector Sensitive energy region: keV Spatial resolution: 1.5cm Time resolution: 5s The outmost chord: 27cm Arc-shape SS pedestal with R=55cm (H) and R=60cm (V) Thin slot-apertures : 520 mm2 (V) 425 mm2 (H) A different adjustable mechanism for 4 thickness of Beryllium absorption foils : 5~6m, 12~13m, 25m, and full open

4 SXR Array Diagnostic with SBDs in HT-7
ASIPP SXR Array Diagnostic with SBDs in HT-7 Plug-in electronics and fast connectors for convenient repairing of the system

5 Schematic drawing of electronics and data acquisition
HT-7 ASIPP Schematic drawing of electronics and data acquisition VAX3300 Computer CAMAC Output DC Regulator Rejecter Power supply ~220V Au-Si detector Signal current transform to Voltage preamplifier with variable gain Sawtooth Heat Pulse Propagation for e Differential Circuit

6 Modification of HT-7 SXR detector
ASIPP Modification of HT-7 SXR detector HAMAMATSU: S N/35N Low terminal capacitor and high speed Down: 0.510mm slit, 1.6cm~0.7cm Below: 0.510mm slit, 1.6cm~0.7cm Above: 1.010mm slit, 1.5cm~0.9cm

7 HT-7U SXR Pinhole Camera
ASIPP HT-7U SXR Pinhole Camera 11, each with 46 elements, 3 toroidal positions, 1-20keV, 1.0cm, cooling plate, adjustable mechanism for protection.


Download ppt "Soft X-Ray Diagnostic System for HT-7 and EAST Tokamaks"

Similar presentations


Ads by Google