Download presentation
Published bySilvester Berry Modified over 9 years ago
1
Janus Convertible Line – interactive Series UPS
2
Content Introduction of JC Series System Block Diagram
Product Features Functions Explanations Product Specifications Q&A
3
Introduction of JC Series
Rack/Tower Convertible 2U Height JC Series 750/1000/1500/2200/3000VA JCXL Series 1000/1500/2200/3000VA
4
Pure Sine-wave Inverter
System Block Diagram AC Output CPU AVR Output Relay Input Relay Battery Pure Sine-wave Inverter Charger AC Input Comm. Interface AC Power Flow Control & Detect DC Power Flow Boost/Buck Design Acceptable Input Range 83~159Vac/165~300Vac Input Voltage Window 110/120/127Vac or 220/230/240Vac +/-25% Voltage Configuration by DIP Switch on Rear Panel
5
Product Features Line-interactive Sine Wave Topology
0.9 Output Power Factor Configurable Output Voltage Window by DIP Switch Toroidal Transformer Technology Built-in AVR Function Tower/Rack Convertible Rotatable User’s Friendly LCD Panel Active RS-232 & USB & SNMP Slot Simultaneously Remote Emergency Power Off Fast Charger inside Hot-swappable Battery Design Extended Runtime Capability (for JCXL Series)
6
Functions Explanations
Display & Control LED Line Mode, Battery Mode, Fault LCD with Backlight Line Bypass, AVR Boost,/Buck, Backup, Battery Level, Battery Low, Load Level, Battery Fault, UPS Fault Keypad Turn-on/Alarm Reset/ Self-test, Turn-off, Reading Scroll
7
Janus RT Series Rear Panel(120V) RJ45 Connectors
Output Configuration DIP Switch USB Port RS232 Port Output Breaker Outlet 10/16A; 15A/20A Input Breaker Inlet EPO SNMP Slot 1000VA/1500VA 2200VA 3000VA
8
Janus RT Series Rear Panel(230V) RJ45 Connectors
Output Configuration DIP Switch USB Port RS232 Port Output Breaker Outlet 10/16A; 15A/20A Input Breaker Inlet EPO SNMP Slot 750/1000/1500VA 2200/3000VA
9
JCXL Series Rear Panel(120V) RJ45 Connectors
Output Configuration DIP Switch USB Port RS232 Port Output Breaker Outlet 10/16A; 15A/20A Cooling Vents Input Breaker Inlet External Battery Connector EPO SNMP Slot 1000/1500VA 2200VA 3000VA
10
JCXL Series Rear Panel(230V) RJ45 Connectors
Output Configuration DIP Switch USB Port RS232 Port Output Breaker Outlet 10/16A; 15A/20A Cooling Vents Input Breaker Inlet External Battery Connector EPO SNMP Slot 1000VA/1500VA 2200VA/3000VA
11
External Communication Interface
Standard Unit : Adapted with RS232 、USB Optional in Slot : 1. WEB/SNMP Card 2. True Relay Contact Card
12
EPO & DIP EPO: Normal Open DIP: Adjust Input Voltage
13
Hot Swappable Battery Replaced from the Front Panel Without Hazard Risk to Users
14
Toroidal Transformer High Efficiency Perfect Output Waveform
Quiet Operation Slim Style
15
Nominal System Voltage
Extended Battery Bank UPS model Nominal System Voltage (connector color) Battery Bank model 1000VA 24VDC (red) BBC08I00070 1500VA 24VDC(red) BBC08I00090 2200VA 48VDC(Gray) BBC08H00070 3000VA BBC08H00090
16
Communication Software
Emily & Upsilon 2000
17
Product Specifications
Model JC750 JC1000 JC1500 JC2200 JC3000 INPUT Acceptable Input Voltage Range 0~340Vac 83~159Vac or 165~300Vac Voltage Window 220/230/240Vac±25% 110/120/127Vac or 220/230/240Vac +/-25% Frequency 45~65Hz(Auto Sensing) OUTPUT Voltage Windows (Bypass) 110/120/127 or 220/230/240Vac +-10% Voltage Window (INV) 220/230/240Vac+/-5% 110/120/127Vac or 220/230/240Vac+/-5% Frequency (IVV/Bypass) 45~65Hz Capacity (VA/W) 750/675 1000/900 1500/1350 2200/1980 3000/2700 Transfer Time 4~6 ms typical Autonomy > 3 min. (at 80% load)
18
Model JCXL1000 JCXL1500 JCXL2200 JCXL3000 INPUT Acceptable Input Voltage Range 83~159Vac or 165~300Vac Voltage Window 110/120/127Vac or 220/230/240Vac +/-25% Frequency 45~65Hz(Auto Sensing) OUTPUT Voltage Windows (Bypass) 110/120/127 or 220/230/240Vac +9 ~ -13.8% Voltage Window (INV) 110/120/127Vac or 220/230/240Vac+/-5% Frequency (IVV/Bypass) 45~65Hz Capacity (VA/W) 1000/900 1500/1350 2200/1980 3000/2700 Transfer Time 3~6 ms typical Autonomy > 5 min. (full load)
19
Model JC750 JC1000 JC1500 JC2200 JC3000 BATTERY Capacity 7AH 9AH Quantity 2pcs 3pcs 6pcs Voltage 24Vdc 36Vdc 72Vdc Recharge Time 5 hours to 90% Model JCXL1000 JCXL1500 JCXL2200 JCXL3000 BATTERY Capacity 7AH 9AH Quantity 4pcs 8pcs Voltage 24Vdc 48Vdc Recharge Time 5 hours to 90%
20
Nominal System Voltage
For JCXL Series Extended Backup UPS 1000VA 1500VA 2200VA 3000VA Battery Bank PN BBC08I00070 BBC08I00090 BBC08H00070 BBC08H00090 Nominal System Voltage 24V 48V Quantity 8 Type 7Ah 9Ah Max. Charge Current 8.4A 10.8A 4.2A 5.4A Connector color Red(+),Black(-) Gray(+),Black(-) Dimensions W x D x H, mm Unit 440 x 482 x 88 Shipping 560 x 675 x 228 Weight, kg 29 33.4 32 36.4
21
Battery Run Time Model Condition JC750 230Vac JC1000 (120Vac/230Vac)
100% Linear Load 2”38 3”14 2”33 2”41 2”32 50% Linear Load 8”35 10”31 8”18 8”40 8”14 At 100% Linear Load Configuration Model UPS UPS + 1 Battery bank UPS + 2 Battery bank UPS + 3 Battery bank JCXL1000 (120Vac/230Vac) 5min 31'30'' 1:04'42' 1:36'18'' 2:03'48'' JCXL1500 (120Vac/230Vac) 18'06'' 46'36'' 1:04'12'' 1:21'54'' JCXL2200 (120Vac/230Vac) 14'54'' 29'12'' 47'54'' 1:11'48' JCXL3000 (120Vac/230Vac) 12'12' 18'24'' 31'12' 47'30''
22
Q & A
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.