Presentation is loading. Please wait.

Presentation is loading. Please wait.

The GLD Concept. MDI Issues Impact on Detector Design L*  Background (back-scattered e+-, , n) into VTX, TPC Crossing angle  Minimum veto angle for.

Similar presentations


Presentation on theme: "The GLD Concept. MDI Issues Impact on Detector Design L*  Background (back-scattered e+-, , n) into VTX, TPC Crossing angle  Minimum veto angle for."— Presentation transcript:

1 The GLD Concept

2 MDI Issues Impact on Detector Design L*  Background (back-scattered e+-, , n) into VTX, TPC Crossing angle  Minimum veto angle for 2-photon process (important for SYSY search), back-scattered e+- into VTX Pair background  VTX radius Synchrotron radiation  Beam pipe / VTX radius, background hits in trackers Muons  Detector hit occupancy Neutrons from the extraction line  Radiation damage on Si DID  TPC resolution Anti-solenoid  Design of very forward detectors Beam timing  Readout scheme of VTX, etc. etc. GLD detector concept study includes all these issues. The baseline design should be compatible with the most severe case: High Lumi option

3 Requirement from Physics Impact parameter:  b = 5  10/(p  sin 3/2  )  m (c/b-tagging) Momentum:  pt /p t 2 = 5x10 -5 /GeV (e.g. H recoil mass reconstruction from Z   pairs) Jet energy:  E /E = 30%/E 1/2 (W/Z invariant mass reconstruction from jets) Hermeticity:  =5 mrad (for missing energy signatures, e.g. SUSY) Sufficient timing resolution to separating events from different bunch- crossings Must also be able to cope with high track densities due to high boost and/or final states with 6+ jets, therefore require: High granularity Good pattern recognition Good two track resolution General consensus: Calorimetry drives ILC detector design

4 Calorimetry at the ILC Much ILC physics depends on reconstructing invariant masses from jets in hadronic final states Kinematic fits won’t necessarily help – Missing particles (e.g. ) + Beamstrahlung, ISR Aim for jet energy resolution ~  Z for “typical” jets Jet energy resolution is the key to calorimetry The best jet energy resolution is obtained by reconstructing momenta of individual particles avoiding double counting Charged particles (60%) by tracker Photons (30%) by ECAL Neutral hadrons (10%) by ECAL+HCAL  Particle Flow Analysis The dominant contribution to jet energy resolution comes from “confusion”, not from single-particle resolution of CAL Separation of particles by fine segmentation / large distance from the IP is important for CAL

5 Calorimetry: Optimization for PFA To avoid the “confusion” and get good jet energy resolution, separation of particles is important for CAL: How? Fine segmentation of CAL High B field Large distance from the IP  Large Detector Often quoted “Figure of Merit”:  : CAL granularity R M : Effective Moliere length

6 Calorimetry: B or R? B-field just spreads out energy deposits from charged particles in jet –not separating neutral particles or collinear particles Detector size is more important – spreads out energy deposits from all particles R is more important than B Dense Jet:B-field neutral +ve - ve Dense Jet:B=0 neutral +ve - ve GLD Concept: Investigate detector parameter space with large detector size (R) and slightly lower magnetic field (B) and granularity

7 GLD Baseline Design Large gaseous central tracker: TPC Large radius, medium/high granularity ECAL: W-Scint. Large radius, thick(~6 ), medium/high granularity HCAL: Pb-Scint. Forward ECAL down to 5mrad Precision Si micro-vertex detector Si inner/forwad/endcap trackers Muon detector interleaved with iron structure Moderate B-field: 3T VTX, IT not shown

8 Vertex detector Role: Heavy flavor tagging Important for many physics analyses: e.g. Higgs branching ratio measurement Efficient flavor tagging requires excellent impact parameter resolution: Goal:  = 5  10/(p  sin 3/2  )  m Sensor technologies Must cope with high background rate Readout 20 times/ train, or Fine pixel (20 times more pixels) option : readout once/ train

9 Vertex detector Main design consideration Inner radius: Beam pipe radius: Dense core of pair background should not hit the beam pipe  B-dependence not so large: ~B -1/2  Large machine-option dependence Back scattered e+- from BCAL (Low-Z mask in front of BCAL should cover down to R<R VTX ) Layer thickness: As thin as possible to minimize multiple scattering  I.P. resolution / tracking efficiency for low p particles GLD baseline design Fine pixel CCD Inner/outer radius: 20(?) – 50 mm Angle coverage: |cos  |<0.9/0.95

10 Si trackers Role: Cover large gap between TPC and VTX  Si Inner Tracker (IT) TPC and endcap ECAL  Si Endcap Tracker (ET) to get better Track finding efficiency Momentum resolution Track-cluster maching in ECAL (PFA) Design optimization Number of layers and their position Wafer thickness Strip or pixel? for the very forward region

11 Main tracker: TPC Performance goal:  pt /p t 2 = 5x10 -5 /GeV combined with IT and VTX Advantages of TPC Large number of 3D sampling Good pattern recognition Identification of non-pointing tracks (V 0 or kink particles) : e.g. GMSB SUSY Good 2-hit resolution Minimal material Particle ID using dE/dx e+ e-  ZH   X

12 TPC Baseline design Inner radius: 40 cm Outer radius: 200 cm Half length: 230 cm Readout: ~200 radial rings Open questions Readout: GEM or Micromegas? Material budget of inner/outer wall and end plate Background hit rate and its effect on spatial resolution due to positive ion buildup (occupancy is OK even with 10 5 hits in 50  s)

13 Tracking performance GLD conceptual design achieves the goal of  pt /p t 2 = 5x10 -5 /GeV  pt /p t 2 (GeV -1 ) By A.Yamaguchi(Tsukuba) Monte Carlo

14 Calorimeter Performance requirement Goal for jet energy resolution is  E /E = 30%/E 1/2 Then, what is the requirement for CAL? The answer is not simple. We need a lot of simulation study of PFA

15 ECAL Current baseline design 33 layers of [3mm W + 2mm Scinti. + 1mm gap (readout elec.)] ~28 X 0, ~1, R M ~18mm Wavelength shifter fiber + MPC (Multi-pixel Photon Counter, =SiPM) readout 4cmx4cm tile and 1cm-wide strips Granularity has to be optimized by PFA simulation study Calibration method for small segments is worrisome Very fine segmentation with Si for first few X 0 is also discussed MPC 400pixels MPC 100pixels (10x10pixels) ~85um ~100um

16 HCAL Current baseline design 50 layers of [20mm Pb + 5mm Scinti. + 1mm gap (readout elec.)]: (“Hardware compensation” configuration) ~6 Wavelength shifter fiber + MPC (Multi-pixel Photon Counter, =SiPM) readout 20cmx20cm tile and 1cm-wide strips Granularity has to be optimized by PFA simulation study Digital HCAL is also considered as an option Open questions Global shape: Octagon, dodecagon, or hexadecagon? How to extract cables? Hamamatsu MPC (H100) spectrum Up to ~40 photon peak! is observed

17 FCAL/BCAL BCAL Locates just in front of final Q Coverage: down to ~5mrad W/Si or W/Diamond (No detailed design yet) FCAL Z~2.3m Also work as a mask protecting TPC from back-scattered photon from BCAL W/Si (No detailed design yet)

18 Muon detector / Magnet Muon detector Possible technology: Scintillator strip array read out with wavelength shifter fiber + MPC Number of layers, detector segmentation, etc. have to be studied Magnet 8 m  3T superconducting solenoid Stored energy: 1.6 GJ Excellent field uniformity for TPC:

19 Cost Issues Major cost consumers: Solenoid, HCAL, ECAL Solenoid Cost~0.523xE(MJ) 0.662 [PDG]~70M$ HCAL Volume~230m 3, Area (all layers)~87Mcm 2 Cost~87M x cost/cm 2 ECAL Volume~22m 3, Area (all layers)~37Mcm 2 Cost~37M x cost/cm 2 Requirement for granularity from physics determines the CAL design and the cost: Simulation study is urgent

20 Summary GLD design study is being carried out both from accelerator point of view and from physics point of view ILC detectors should be optimized for PFA performance, and large detectors are suitable for that In GLD concept study, we investigate detector parameter space with large detector size and slightly lower B and CAL granularity Baseline design of GLD has been shown, but current GLD baseline design is not really optimized. More simulation study, sub-detector R&D effort, and new ideas are necessary  The purpose of this workshop


Download ppt "The GLD Concept. MDI Issues Impact on Detector Design L*  Background (back-scattered e+-, , n) into VTX, TPC Crossing angle  Minimum veto angle for."

Similar presentations


Ads by Google