Enea Detectors Range
2
Introducing new devices
ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR ED200 – HEAT DETECTOR ED300 – COMBINED SMOKE AND HEAT DETECTOR
3
Introducing new devices
Designed and manufactured at Inim electronics, it is a 100% italian product
4
Introducing new devices
Each device of the new ranges has been approved by LPCB which is one of the most prestigious notification body in fire detection EN54-5 : Heat Detectors EN54-7 : Smoke Detectors EN54-17 : Short Circuit Isolator EN54-18 : Input/Output devices
5
KEY FEATURES Optical Smoke detectors are based on th eprinciple of the light scattering, to avoid false alarm it is important to avoid contaminations in the analysis chamber
6
Introducing new devices
Top side completely sealed to avoid dust or water condensation to reach the chamber One of the most common false alarm or fault reason is the dust coming from the pipes or condensating water dropping from the top side
7
Introducing new devices
Metal mash agains insect wit less than 500um holes diameter One of the biggest problems of optical smoke detectors is dust or insect entering in the chamber
8
Introducing new devices
Electronic circuit completely WAX coated to avoid any contamination Moisture or environmental pollution may affect the behaviour of hi sensitive electronics circuits in the detector
9
Introducing new devices
Sensitive part of the circuit completely shielded by a metal cage Electromagnetic noise may affect the measurement of the hi gain amplifier generating false alarms
10
Introducing new devices
Last generation CPU inside each detector whith hi false alarm rejection algorithm The measurement of the smoke chamber and thermal probe are evaluated by the internal CPU and by means of the algorithm designed from the Inim R&D department an hi rejection to false alarm is achieved
11
Introducing new devices
Smoke chamber easy to open for clean up operations In case of detector’s chamber contamination detector can be easily opened and cleaned with some air or a soft brush
12
Introducing new devices
Each Detector is Full tested with automatic test equipment which measure each single component and verify each electrical connection
13
Introducing new devices
Each Detector is Calibrated with a two stage process : one in free air and another one in a smoke tunnel to ensure the same response from each sample
14
Introducing new devices
Each Detector is subjected to a «Burn IN test» of 24 hours: the 80% of electronic components failure occur during the first 24 hours of theyr life, detectors live theyr first 24 hours in our burn in test!
15
Introducing new devices
Universal mounting base for every detector model Clip for line continuity restore in case of detector removal
16
Introducing new devices
Relay base available direct driving of any type of external device
17
Each device is identifyed by a serial number
Introducing new devices Each device is identifyed by a serial number The serial number is reported on the back label and on two small detachable labels : this allow to stick a serial number to map and a serial number to mounting base
18
Introducing new devices
Thanks to LOOPMAP technology, which is the ultimate technology in loop addressing and fault finding, no any address operation is required
19
Introducing new devices
After the loop has been wired up, by using the panel and its configuration software or using the EDRV1000 driver with the included FireGenius software…
20
Introducing new devices
The loop wiring is automatically detected and a graphic report (including any T junction etc) is available:
21
Diagnostic features using Smartleague configuration software:
Introducing new devices Diagnostic features using Smartleague configuration software:
22
Contamination analysis using Smartleague configuration software:
Introducing new devices Contamination analysis using Smartleague configuration software:
23
If some divice is not responding
Introducing new devices The interactive graph show where there is a short circuit (each device include a short circuit isolator) Right button mouse click If some divice is not responding Allow to Manually activate the 3 colour leds, the outputs etc. in order to test the loop
24
Introducing new devices
For each detector Smoke and heat sensitivity can be adjusted and are available early warning threshold for Smoke and heat level
25