Connie M. Borror, Arizona State University West Christine M. Anderson-Cook, Los Alamos National Laboratory Bradley Jones, JMP SAS Institute Construction and Evaluation of Response Surface Designs Incorporating Bias from Model Misspecification
2
Motivation Response surface design evaluation (and creation) assuming a particular model Single number efficiencies Prediction variance performance Mean-squared error Model misspecification? What effect does this have on prediction and optimization?
3
Motivation Examine effect of model misspecification Expected squared bias Prediction variance Expected mean squared error Using fraction of design space (FDS) plots and box plots Evaluate designs based on the contribution of ESB relative to PV.
4
Scenario Cuboidal regions True form of the model is of higher order than the model being fit. Examine Response surface models when the true form is cubic Screening experiment when the true form is full second order.
5
Model Specifications The model to be fit is Y = X 1 1 + ε X 1 = n × p design matrix for the assumed form of the model The true form of the model is Y = X 1 1 + X 2 2 + ε X 2 = n × q design matrix pertaining to those parameters ( 2 ) not present in the model to be fit (assumed model).
6
Model Specifications 2 in general, are not fully estimable Assume 2 ~ N(0, )
7
Criteria Mean-squared error Expected squared bias (ESB): Expected MSE sum of PV and ESB
8
Fraction of Design Space (FDS) Plots Zahran, Anderson-Cook, and Myers (2003) scaled prediction variance values are plotted versus the fraction of the design space that has SPV at or below the given value Adapt this to plot ESB and EMSE as well as PV. We use FDS plots and box plots to assess the designs
9
Cases I. Two-factor response surface design Assume a second-order model: True form of the model is cubic:
10
Case I Designs Central Composite Design (CCD) Quadratic I-optimal (Q I-opt) Quadratic D-optimal (Q D-opt) Cubic I-optimal (C I-opt) Cubic D-optimal (C D-opt) Cubic Bayes I-optimal (C Bayes I-opt) Cubic Bayes D-optimal (C Bayes D-opt)
11
Case I CCD
12
Case I Designs CCD (ESB and EMSE performance as bias increases)
13
Case I Designs PV for all designs
14
Case I Designs ESB for all designs
15
Case I Designs EMSE for all designs
16
Case I Designs FDS for EMSE for all designs
17
Case II Four factor response surface design Assume a second-order model: True form of the model is cubic: 20 additional terms as we move from the second- order model to cubic.
18
Case II Designs Six possible designs, with n = 27 runs Central Composite Design (CCD) Box Behnken Design (BBD) Quadratic I-optimal (Q I-Opt) Quadratic D-optimal (Q D-Opt) Cubic Bayes I-optimal (C Bayes I-Opt) Cubic Bayes D-optimal (C Bayes D-Opt) Note: Cubic I- and D-Optimal not possible with available size of design
19
Case II PV for all designs
20
Case II EMSE for all designs
21
Case II FDS plot of EMSE for Four Factors
22
Case III Eight-factor Screening Design Assume a first-order model: True form of the model is full second-order:
23
Case III Designs 2 8-4 fractional factorial design with 4 center runs D-optimal (for first order) Bayes I-optimal (for second order) Bayes D-optimal (for second order)
24
Case III Designs The difference in the number of terms from the assumed to the true form of the models increases from 8 to 44. We would expect bias to quickly dominate EMSE.
25
Case III PV for all designs
26
Case III ESB for all designs
27
Case III EMSE for all designs
28
Design Notes For the two-factor case: The I-optimal and CCD were equivalent. They performed the best based on minimizing the maximum EMSE They performed the best based on prediction variance
29
Design Notes For the four factor case, the BBD was best based on EMSE criteria (in particular, the 95 th percentile, median, mean) when size of the coefficients of missing terms are moderate to large The I-optimal design was competitive for this case only if small amounts of bias were present. As the number of missing cubic terms increases, the BBD was best for EMSE.
30
Design Notes I-optimal designs were highly competitive over 95% of the design region; not with respect to the maximum PV, ESB, and EMSE. Cubic Bayesian designs did not perform well.
31
Design Notes In the screening design example: The D-optimal designs best if the assumed model is correct, but break down quickly if quadratic terms are in the model Much more pronounced than in the response surface design cases. Quadratic Bayesian I-optimal design was best based on mean, median, and 95 th percentile of EMSE The 2 8-4 fractional factorial design was best with respect to the maximum EMSE. The 2 8-4 design was best for both PV and ESB when the PV and ESB contribution to the model were balanced.
32
Conclusions Appropriate design can strongly depend on the assumption that we know the true form of the underlying model If we select designs carefully it is often possible to select a model that predicts well in the design space, and provide some protection against missing model terms. The ESB approach to assessing the effect of missing terms provides is advantageous: do not have to specify coefficient values for the true underlying model, Instead, the relative size of the missing terms can be calibrated relative to the variance of the observations.
33
Conclusions Size of the bias variance relative to observational error needed to balance contributions from PV and ESB is highly dependent on the number of missing terms from the assumed model. As the number of missing terms increases, the ability of designs to cope with the bias decreases substantially different designs are able to handle this increasing bias differently.