Beam Test Results for a Large-area GEM Detector Read Out with Radial Zigzag Strips Aiwu Zhang, V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger Dept. of Physics and Space Sciences, Florida Institute of Technology APS April meeting, Savannah, Georgia 08/04/2014
2
Outline Motivation for the beam test Large-area GEM detector & zigzag readout Beam test setup at Fermilab Basic characteristics of the GEM detector Tracking & Resolution results Summary 4/8/2014Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang2
3
Motivation 4/8/20143Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang The next QCD frontier can be explored at a new Electron-Ion Collider (EIC). The proposed EIC candidates are eRHIC at BNL and MEIC at J-Lab. The FLYSUB consortium is performing R&D on tracking and particle ID with GEM detectors at a future EIC detector. FLYSUB: FLorida Tech (FIT), Yale U., Stony Brook U., U. of Virginia and Brookhaven National Lab. New members are joining into this consortium. The consortium conducted a joint beam test at Fermilab in October 2013. A 1-m long trapezoidal GEM detector with zigzag readout strips designed by FIT was studied as an option for EIC forward tracking during this beam test. EIC at Brookhaven National Lab. EIC at Jefferson Lab. (MEIC/ELIC) Conceptual design of EIC detector Forward/backward GEM trackers eRHIC
4
Large GEM detector with zigzag readout 4/8/20144Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang CMS GE1/1-III GEM foils with trapezoidal shape (1m long, 22-45cm wide) are used Readout boards Left: Zigzag strips designed by FIT Right: Straight strips (for CMS upgrade). Both zigzag and straight strips are radial: strips develop in a fan-shape, full opening angle for zigzag strips is 10°. Eight sectors with 8 APVs (128 channels each) fully read out; need only 1/3 electronic channels of std. CMS GE1/1-III GEM detector (see Vallary Bhopatkar’s talk at beginning of this session). Zigzag strips (1.37mrad pitch) 0.1mm Zigzag strips Straight strips 12 3456 7 8 -sectors 1.37 mrad
5
Beam test setup at Fermilab 4/8/20145Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang 1-m GEM w/ zigzag readout Trackers 4 reference GEM detectors (trackers) Gas: Ar/CO 2 (70:30) Beam: 25GeV, 32GeV mixed hadrons (π, K etc.) and 120GeV protons Zigzag 3-GEM det. gaps: 3/1/2/1mm
6
Basic performances of the zigzag GEM 4/8/20146Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang Cluster size: number of strips in a cluster. Mean cluster size value increases exponentially with HV (approximately). Cluster charge distribution fits well to a Landau function. We find the typical increase of “gain” with HV for the middle- sector 5. Mean cluster size vs. HV on sector 5 (number of hits in a cluster) Stat. errors smaller than marker size Total cluster charge distribution in sector 5 at 3200V MPV value of charge distribution vs. HV Stat. errors smaller than marker size peak pos.
7
Basic performances (cont.) 4/8/20147Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang We scanned two positions on each sector from sector 1 to 7. From sector to sector the response varies by 20%, which is probably caused by uneven foil gaps. Detector efficiency on sector 5 vs. HV can be fitted with a Sigmoid function. Different thresholds were compared: N sigma, N=3,4,5,6, where sigma is width of pedestal distribution. Plateau efficiency with 5 sigma cut is (98.4 ± 0.2)% Charge in different sectors (uniformity) Detection efficiency
8
Tracking method for the zigzag GEM 4/8/20148Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang After aligning the trackers to each other with shifts and rotations, they are giving resolutions of 70μm or better (≈ typical spatial resolution for std. GEM detectors) in both X and Y. The radial zigzag strips measure the azimuthal coordinate ϕ and have a pitch of 1.37mrad, so we study the resolution in natural polar coordinates (r, ϕ). Tracking in polar system was demonstrated to be working as well as in the Cartesian system. The trackers have azimuthal resolutions around 30μrad. The ϕ resolution of the zigzag GEM detector can be studied if its vertex is taken as the origin of the tracking system. (X,Y) offsets need to be found to align the tracker origin to the vertex of the zigzag GEM detector. REF Det. X X offset Eta 5 vertex 10° Y offset σ=21μrad Inclusive residual for 1 st trackerResolution in ϕ for trackers Errors smaller than marker size Aligning trackers to zigzag GEM det.
9
Three alignment checks for (X,Y) offsets 4/8/20149Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang Track χ 2 in ϕ vs. tracker X offset for Y = -36.5mm Minimal point gives X = -1866.4mm Residual mean should be centered at 0 Inclusive residual width
10
Residuals after the alignment 4/8/201410Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang After (X,Y) offsets are optimized, both inclusive and exclusive residuals are calculated for the zigzag GEM detector. The residuals shown above are for sector 5 @3300V. Inclusive residual (zigzag GEM is included in track fit) σ = 215μrad Exclusive residual (zigzag GEM is excluded from track fit) σ = 270μrad
11
Spatial resolution for the zigzag GEM 4/8/201411Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang Resolution vs. HV in middle-sector 5 Resolution as a function of -sectors Left: Higher voltage, i.e. higher gas gain, gives better resolution as expected. Right: Resolutions in different sectors at 3200V. We observe similar azimuthal resolutions (variation about 10%) in the first six sectors. Resolution in sector 7 is a little worse; the reason is likely to be lower gas gain in that sector.
12
Summary and Conclusion 4/8/201412Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang The zigzag strip readout method reduces the number of strips and readout channels by a factor of 3 which reduces system cost. The FNAL beam test was successful. We operated 10 GEM detectors including a large trapezoidal Triple-GEM with zigzag readout strips. The large-area zigzag GEM detector was working quite well. It had high and stable gain, plateau detection efficiency of 98% and spatial resolution of 241μrad (449μm) at 3300V. The resolution is expected to be improved further by also correcting for the non-linearity of charge sharing between strips (response fct.) The structure of zigzag strips can be optimized to get even better resolution. For example, the interleaving between zigs and zags can be improved by industrial PCB factories to yield better charge sharing. We conclude that a zigzag GEM detector can be an option for the cost-conscious construction of a forward tracker in an EIC detector.
13
4/8/201413Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang We would like to acknowledge BNL for the support of this work through the EIC RD-6 collaboration and the staff of the FNAL test beam facility for all their help. The FLYSUB consortium
14
Backup - EIC physics 4/8/201414Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang (inclusive or semi-inclusive) DIS is a powerful way to probe the internal structure of nucleons Transverse Momentum Dependent parton distributions (TMDs) open a new window to understand some of the most fundamental aspects of QCD Address the spin problem of the nucleon; illuminate the role played by angular momentum of partons Two golden measurements on an EIC: 3-d imaging of gluons and quarks, and their spins Di-jet measurements
15
Backup- how to transfer resolution from μrad to μm 4/8/2014 [μm]σ r [μm] [μrad]σ ϕ [μrad] [μm]σ x [μm] [μm]σ y [μm] REF23.6464.2213.746945 REF3-3.669-5.731-3.669-126966 UVA3-11.655-3.623-11.655-85049 REF110595251059105553 Resolutions in (x,y) are also calculated at this origin. Resolutions in r are almost the same as resolutions in X. The last column shows the calculated resolutions in y from resolutions in ϕ, they match with the measured resolutions in y. Also, ≈ and ≈ *L Tracking in polar coordinates works well and gives high resolutions. σϕσϕ σyσy L 15Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang
16
Backup – electronics, SRU The test beam took data for 60 APVs (128ch/ea.) simultaneously through the Scalable Readout Unit (SRU). Data were taken with DATE and amoreSRS under Linux system. 4/8/201416Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang
17
Backup -- Rotation 4/8/2014 Beam Test of a GEM Detector with Zigzag Readout / Aiwu Zhang 17 Rotation of the Zigzag detector should be minimal at 0 if the alignment is correct rotation The detector might be rotated a small angle relative to the first tracker. The angle should be close to 0 if alignment is correct.