Download presentation
Presentation is loading. Please wait.
Published byAntony Garrett Modified over 9 years ago
1
10 February 20041 Doors Software Overview
2
10 February 20042 This presentation is an overview of the basic fundamentals of the Doors software. –Host computer specifications –Configuration of controllers/doors/network –Setup system options/time zones/holiday schedules/access groups –User enrollment/network updates –Event configuration/File management –Real-time monitoring/event reporting Each item is discussed in greater detail in its respective presentation. Doors Software
3
10 February 20043 Doors software can handle: –Up to 32 system operators, each with password protection and configurable privileges. –Up to 32 time zones (including dial time zones), each with 4 start/stop intervals. –Up to 3 holiday schedules, each with up to 32 definable holiday dates. –An unlimited number of Access Groups (subject to available hard disk space). –Up to 6 sortable user definable text fields for individual user information. –A virtually unlimited number of cards/users for use with a PXL controller. Each controller can have its own set of users, but an individual controller can only handle the following number of cards. Doors Software
4
10 February 20044 Doors Software Standard RAM Extended RAM Temp Users Enabled Temp Users Not Enabled PXL-25010,92065,535-- PXL-500*/ PXL-510 --19,11065,535 EntraGuard Gold 750--- * Time and Attendance Terminals are constructed using PXL-500 controllers.
5
10 February 20045 Doors Software Intuitive, can be learned in a few hours (not days!) Used with the following Keri products: –PXL-500/510 – PXL-250 –Entraguard Telephone Entry – Time and Attendance Can integrate with the NetworX (Caddx) NX-8E alarm panel
6
10 February 20046 Doors Software Allows you to manage –Up to 256 doors per site (2 per controller using SB-593s) –Up to 128 controllers per site –Up to 255 sites
7
10 February 20047 Robust and Flexible Custom communications protocol –Minimizes general protection faults (GPFs) and system crashes No dedicated PC required –Only required for downloading or uploading information or for system monitoring
8
10 February 20048 Tool Bar and Pull-Down Menu Tool bar - quick access to most used features Pull-down menus to access all features
9
10 February 20049 Online Help File Online version of the Users Guide available to provide complete technical assistance
10
10 February 200410 Doors is Windows* Based Software True Windows program using Windows features –Resizing, relocation, drag and drop, multiple windows, etc. * Windows is a trademark of the Microsoft Corporation
11
10 February 200411 Multiple Windows Platforms Doors runs under these operating systems: v4.0 only
12
10 February 200412 Host Computer Specifications PC with a P-90 or faster microprocessor –Minimum of 16 MB of RAM* –SVGA graphics card and monitor –CD-ROM (optional CD-R/RW for system backup) –3.5” floppy disk drive, keyboard, mouse –50 MB of hard disk space *Badging option requires more RAM and hard disk space to support the badging graphics functions.
13
10 February 200413 Host Computer Specifications –COM port To support an external modem or direct serial connection or External, 9600 baud (or faster), Keri approved, modem* * Entraguard Telephone Entry controllers require the use of external modems
14
10 February 200414 Auto-configure Controllers One click automatically polls all controllers in the access control network –Retrieves controller/door configuration information and places it into the Controller spreadsheet Auto-Config Button
15
10 February 200415 Setup Doors Allows an operator to name and define the configuration and operation parameters for all doors
16
10 February 200416 I/O Configuration Allows an operator to name and define the use and operation of auxiliary inputs and outputs
17
10 February 200417 Link Configuration Allows an operator to define which inputs are assigned to which outputs –Allows input events to drive output actions
18
10 February 200418 Controller Status Allows an operator to review and verify controller and network conditions Retrieve information for one or all controllers
19
10 February 200419 Network Configuration Allows an operator to configure communication parameters for serial or modem connections –Allows setup of a Personal Identification Number (PIN) for greater security –Allows setup of a modem initialization string for approved non-Keri products
20
10 February 200420 Network Configuration Allows an operator to configure communication parameters for TCP/IP connections* * Communication may be made by either serial connection (direct or modem) or TCP/IP.
21
10 February 200421 System Options –Sites –Badging –EntraGuard (Telephone Entry) –Network Master Parameters –Local Anti Passback –Door Type (Door, Gate, Elevator, Time and Attendance) –User Data File Export/Import –Rollcall/Track –Card + Pin (P-650) –Alarm Control –Temp Users –Dual Verification Allows an operator to enable various system options
22
10 February 200422 Multiple Site Management Manage a single site or up to 255 sites via –Serial connection (either by direct serial connection or modem connection) –TCP/IP network
23
10 February 200423 Photo ID Badging Create and print photo ID badges Uses the Doors cardholder/user database On-command photo display
24
10 February 200424 Entraguard Telephone Entry Integrates telephone entry with access control Uses the Doors cardholder/user database
25
10 February 200425 Alarm Panel Interface Integrates with the NetworX (Caddx) NX-8E alarm panel Allows proximity readers and users to arm and disarm the alarm panel Reports alarm panel events with access events
26
10 February 200426 Update Network SMART UPDATE - allows you to send only new/changed information to controllers TOTAL UPDATE - allows you to send all information to controllers COLLECT EVENTS – collects all events from all controllers
27
10 February 200427 Setup Time Zones Define the time periods to be applied to access groups, auto-unlock/lock door function, and I/O operations –Up to 32 time zones, each with 4 start/stop times
28
10 February 200428 Setup Holiday Schedules Define the holidays to be applied to access groups, auto-unlock/lock door function, and I/O operations –3 holiday schedules, each with up to 32 dates –On-board calendar
29
10 February 200429 Access Groups Combines time zones and doors into a superset of information to define users’ access privileges (where and when users may access secure areas) –A Windows “Wizard” is used to step the operator through the process –Create an unlimited number of Access Groups
30
10 February 200430 User Enrollment Allows an operator to enroll users for access control, telephone entry or mixed access networks –Enrollment through a Windows “Wizard”
31
10 February 200431 Enter User Information Enter user identification information and set user access parameters User information is managed via an Excel-like spreadsheet or through dialog boxes
32
10 February 200432 Customizable Information Fields Up to 6 operator definable fields User information is managed via an Excel-like spreadsheet or through a dialog box
33
10 February 200433 Event Configuration Each controller stores up to 3,640 events Allows you to define controller event handling –Save to file– View in a monitor window –Report or ignore– Audibly alert an operator –Auto-download from controller based on event capacity
34
10 February 200434 Event File Management Store event files in a weekly, monthly, or yearly format Restore files to review past events
35
10 February 200435 Operators Up to 32 system operators, each with –Unique password protection –Configurable privileges - You define the operations each operator is allowed to perform
36
10 February 200436 Operate Doors Manual System Operation allows: –Lock or unlock doors –Update door/controller operating parameters
37
10 February 200437 Real-time Monitoring Monitor events occurring on controllers in real-time (including display of any associated photos) Collect all events stored on controllers
38
10 February 200438 Monitor Window Monitor events occurring on controllers in real-time Collect all events stored on controllers
39
10 February 200439 Display Photo Shows photo of users as they access the “A” reader on controller #1 of the network in real- time
40
10 February 200440 Output Control Allows an operator to manually control outputs
41
10 February 200441 Event Reports Quick Search Event Reporting - uses radio buttons and pull-down lists to quickly generate summary reports
42
10 February 200442 Event Reports Power Search Event Reporting - uses Boolean operators to sift the event database and create reports with specific information
43
10 February 200443 Event Reports Formatted Database Reporting – uses an integrated Crystal Reports viewer to provide Doors database configuration information
44
10 February 200444 Dealer Contact Information Text Allows a dealer to add contact information to the Help > About pull-down menu window
45
10 February 200445 Dealer Contact Information Bitmap Allows a dealer to add a “splash screen” that is displayed when Doors is opened