The Letter Report When is it appropriate? Who is the audience?
2
Characteristics 3-5 pages 0-3 tables or figures emphasize important points avoid details choose words carefully avoid repetition Concise Writing!
3
No Title Page no title authors sign letter date is in letter format affiliation is in letterhead position is with signature
4
No Headings or Numbered Sections no table of contents no list of figures no list of tables no list of references Use footnotes
5
Summary and Introduction no separate sections must present purpose and state important results early in the paper (first paragraph) lacks repetition of a formal report
6
References treated as footnotes only a few references no list of references
7
Tables and Figures same format as in other reports Few in number! Only the important ones should be self-contained documents place at end of letter or within letter
8
No Nomenclature Section all symbols must be defined as they are introduced use only important equations
9
Backup Information raw data calculations error analysis experimental equipment experimental procedures
10
Outline recipient and address salutation project objective important results description of experimental procedures -very brief, innovative techniques, problems encountered
11
Outline continued results - analysis - discussion recommendations signature
12
205 East 2nd South Apt 6 SLC, Utah 84103 February 6, 1992 Professor Noel de Nevers Department of Chemical Engineering University of Utah Salt Lake City, Utah 84112 Dear Dr. de Nevers: During the period from January 6 to January 27, 1992, the members of Group F calibrated and evaluated the performance of an Omega Model HX93V relative-humidity and temperature transmitter (Omega Engineer., Stamford Connecticut). The transmitter was calibrated with an Omega HX92-CAL relative-humidity calibration kit, and its accuracy was tested with various solutions of ethylene glycol and water ranging from 10% to 100% relative humidity (RH). The transmitter was accurate to within 5%
13
RH at higher relative humidities (>50%) but was not accurate to within 5% RH at humidities lower than 50%. The transmitter's performance in a moving airstream at temperatures greater than room temperature was also investigated. A cardboard tube and an air blower containing a heating element supplied a suitable stream of heated air. A brief summary of the calibration and the results of our performance evaluation follow: …….