Rev 3.0913-1 Simulator Theory and Operation
2
Rev 3.0913-2 n EACH BREATH TEST MUST BE PRECEEDED BY A REFERENCE ANALYSIS n REQUIRED BY THE CDPHE RULES AND REGULATIONS, 5 CRR 1005-2 n THE DEVICE USED TO GENERATE THE REFERENCE VAPOR IS CALLED BREATH ALCOHOL SIMULATOR OR “SIMULATOR” n H2O AND ETOH IS USED IN LUE OF BLOOD AND ETOH n EACH BREATH TEST MUST BE PRECEEDED BY A REFERENCE ANALYSIS n REQUIRED BY THE CDPHE RULES AND REGULATIONS, 5 CRR 1005-2 n THE DEVICE USED TO GENERATE THE REFERENCE VAPOR IS CALLED BREATH ALCOHOL SIMULATOR OR “SIMULATOR” n H2O AND ETOH IS USED IN LUE OF BLOOD AND ETOH Use and Theory
3
Rev 3.0913-3 Use and Theory n THE AMOUNT OF ETOH IN 2100 ml OF DEEP LUNG AIR AT 34.0 C ETOH IN 1 ml OF ATERIAL BLOOD n SIMULATOR SOLUTION 0.100 grams OF ETOH PER 2100 Liters OF AIR AT 34.0 C n PREPARED BY CERTIFICATION UNIT n VALIDATES THE PERFORMANCE OF THE 5000EN n THE AMOUNT OF ETOH IN 2100 ml OF DEEP LUNG AIR AT 34.0 C ETOH IN 1 ml OF ATERIAL BLOOD n SIMULATOR SOLUTION 0.100 grams OF ETOH PER 2100 Liters OF AIR AT 34.0 C n PREPARED BY CERTIFICATION UNIT n VALIDATES THE PERFORMANCE OF THE 5000EN
4
Rev 3.0913-4 Functional Structure Functional Structure AIR INLET TUBE ON/OFF-RESET SWITCH HEATER INDICATOR HEATER INDICATOR VAPOR PORT BAFFLE PLATES GLASS CONTAINER HEATING ELEMENT HIGH INTENSITY L.E.D. DISPLAY HIGH INTENSITY L.E.D. DISPLAY AGITATOR TEMPERATURE SENSOR TEMPERATURE SENSOR DISPERSION TUBE
5
Rev 3.0913-5 Exclusive Features of the Guth Model 2100 Simulator n MICROPROCESSOR ENHANCED : -PERFORMS INTERNAL DIAGNOSTICS -MONITERS TEMPERATURE SENSOR, RFI CIRCUITRY -CONTROLS AGITATOR MOTOR, DISPLAY DRIVER, COMMUNICATIONS AND A/V INFORMATION n MICROPROCESSOR ENHANCED : -PERFORMS INTERNAL DIAGNOSTICS -MONITERS TEMPERATURE SENSOR, RFI CIRCUITRY -CONTROLS AGITATOR MOTOR, DISPLAY DRIVER, COMMUNICATIONS AND A/V INFORMATION
6
Rev 3.0913-6 n TEMPERATURE SENSOR: -RUGGED DESIGN: STAINLESS STEEL, BRASS -STABLE TEMPERATURE RANGE: MAINTAINS A PRECISE RANGE OF 34 C .02 C -ACCURACY OF INSTRUMENT TEMPERATURE READING IS .05 C Exclusive Features of the Guth Model 2100 Simulator
7
Rev 3.0913-7 n ELECTRONICALLY PROTECTED: -INTERNAL POWER TRANSFORMER AND OPTICALLY ISOLATED CONTROL COMPONENTS OPTICALLY ISOLATED CONTROL COMPONENTS PREVENTS A.C. LEAKAGE TO ELECTRONICS -R.F.I. PROTECTED -HEATING ELEMENT PROTECTED FROM OVER HEATING WHEN TEMPERATURE SENS0R IS DEFECTIVE OR REMOVED FROM SOLUTION -EXTERNAL FUSE PROVIDES PROTECTION IN CASE OF ELECTRICAL MALFUNCTION n ELECTRONICALLY PROTECTED: -INTERNAL POWER TRANSFORMER AND OPTICALLY ISOLATED CONTROL COMPONENTS OPTICALLY ISOLATED CONTROL COMPONENTS PREVENTS A.C. LEAKAGE TO ELECTRONICS -R.F.I. PROTECTED -HEATING ELEMENT PROTECTED FROM OVER HEATING WHEN TEMPERATURE SENS0R IS DEFECTIVE OR REMOVED FROM SOLUTION -EXTERNAL FUSE PROVIDES PROTECTION IN CASE OF ELECTRICAL MALFUNCTION Exclusive Features of the Guth Model 2100 Simulator
8
Rev 3.0913-8 Guth Simulator Error Codes MESSAGE PLATE MOUNTED ON SIMULATOR QUICK REFERENCE GUIDE MESSAGE PLATE MOUNTED ON SIMULATOR QUICK REFERENCE GUIDE
9
Rev 3.0913-9 * NOTIFY CDPHE Guth Simulator Error Codes
10
Rev 3.0913-10 * NOTIFY CDPHE Guth Simulator Error Codes
11
Rev 3.0913-11 * NOTIFY CDPHE Guth Simulator Error Codes
12
Rev 3.0913-12 Correct Positioning of Simulator Tubing and Clamp #1 Shows the correct orientation of the Simulator Tubing Elbow #2 Shows the correct positioning of the Simulator Clamp Make sure the clamp is tightened all the way closedMake sure the clamp is tightened all the way closed When sending the simulator in for repairs, remove the tubing at the clamp andWhen sending the simulator in for repairs, remove the tubing at the clamp and disconnect the heated tube at the disconnect joint Keep all tubing and the jar at your locationKeep all tubing and the jar at your location
13
Rev 3.0913-13