Download presentation
Presentation is loading. Please wait.
Published byLeslie Lester Modified over 9 years ago
1
1 Common network architectures for PBB, PBB-TE and EOTN networks Maarten Vissers 2011-05-11
2
2 1. PBB and PBB-TE network EVC(C-VLAN) via EC(S-VLAN) IB-BEB UNI PNP S mp2mp B-VLAN or p2p TESI mp2mp B-VLAN or p2p TESI mp2mp B-VLAN or p2p TESI EVC = C-VLAN EC = S-VLAN S-VID Translation at PBBN domain boundaries (in CNPs) mp2mp B-VLANs or p2p TESIs in each domain no MAC address collisions in PBBN domains (multiple single- domain PBBNs) S-VID Translation locations
3
3 2. PBB network EVC(S-VLAN) via EC(BSI) IB-BEB UNI PNP S EVC = S-VLAN EC = BSI I-SID Translation at PBBN domain boundaries (in CBPs) mp2mp B-VLANs in each domain potential MAC address collisions in PBBN domains (multi-domain PBBN) mp2mp B-VLAN I-SID Translation locations
4
4 3. PBB network EVC(C-VLAN) via EC1(S-VLAN) over EC2(BSI) IB-BEB UNI PNP S EVC = C-VLAN EC1 = S-VLAN, EC2 = BSI S-VID Translation at PBBN network boundary (in CNP) I-SID Translation at PBBN domain boundaries (in CBPs) mp2mp B-VLANs in each domain potential MAC address collisions in PBBN domains (multi-domain) B-VLAN I-SID Translation locations S-VID Translation location
5
5 4. EOTN network EVC(C-VLAN) via EC(S-VLAN) EVC = C-VLAN EC = S-VLAN S-VID Translation at EOTN network boundary (in ONP and PNP) p2p ODUk connections in each domain no MAC address collisions (no PBBN domains) ONP p2p ODUk S-VID Translation locations
6
6 EC frame tagging in PB, PBB, PBB-TE, EOTN NetworkEC type 1 frame tagEC type 2 frame tag PB + PBB I (PEB, PB, IB-BEB, BCB only) S-Tag Note: in B-VLAN an I-Tag or S+I-Tag is used To be defined PB + PBB II (PEB, PB, IB-BEB, TB-BEB, I-BEB, B- BEB, BCB) S-Tag Note: Inside PBB network the EC frames are carried inside a 2 nd EC frame, which is I-Tagged I-Tag PB + PBB-TE (PEB, PB, IB-BEB, BCB) S-Tag Note: in ESP an I-Tag or S+I-Tag is used To be defined EOTN (TEB,TB, OTN XC) S-TagTo be defined EC Type 1: EC carrying an EVC which is not-MAC-in-MAC encapsulated EC Type 2: EC carrying an EVC which is MAC-in-MAC encapsulated
7
7 EC awareness in PB, PBB, PBB-TE, EOTN NetworkEVC-to-EC mapping EC MEP/MIP functions EC AIS/LCK insertion EC-to-server mapping PB + PBB I (PEB, PB, IB-BEB, BCB only) PEP CNP PIP PNP CNP PIP PNP CNP PIP PNP PB + PBB II (PEB, PB, IB-BEB, TB-BEB, I-BEB, B- BEB, BCB) PEP CNP PIP CBP CNP PIP CBP PNP CNP PIP CBP PNP CNP PIP CBP PNP PB + PBB-TE (PEB, PB, IB-BEB, BCB) CEP CNP PIP PNP CNP PIP PNP CNP PIP PNP EOTN (TEB,TB, OTN XC) CEP CNP PNP ONP PNP ONP PNP ONP
8
8 Analysis of EC Type 2 Tagging options For deployment in PB+PBB I, PB+PBB-TE and EOTN
9
9 Untagged EC Type 2 frame format Untagged EC Type 2 frames are EVC frames with additional MAC Header including TYPE (89-10), B-SA, B-DA fields Format is present at input/output ports of EC MEP and MIP functions Untagged EC Type 2 OAM frames are OAM PDUs with additional MAC Header including TYPE (89-02), B-SA, B-DA MSDU Type EVC Frame C-DA C-SA Untagged EC Type 2 Frame (= untagged BSI Frame) B-DA B-SA C-DA C-SA MSDU Type = 89-10 Type Untagged EC Type 2 OAM Frame B-DA B-SA OAM PDU Type = 89-02
10
10 Tagged EC Type 2 frame format alternatives There are three EC Type 2 frame tagging alternatives 1.I-Tagging 2.S-Tagging 3.I+S-Tagging TPID = 88-E7 I-SIDPCP DEI Res2 0 Res1 B-DA I-SID B-SA C-DA C-SA MSDU Type I-Tagged EC Type 2 Frame B-DA B-SA C-DA C-SA MSDU Type S-Tagged EC Type 2 Frame Type = 89-10 S-VIDPCP DEI TPID = 88-a8 B-DA B-SA C-DA C-SA MSDU Type I+S-Tagged EC Type 2 Frame S-VIDPCP DEI TPID = 88-a8 TPID = 88-E7 I-SIDPCP DEI Res2 0 Res1 I-SID = S-VID + 4096 TPID = 88-E7 I-SIDPCP DEI Res2 0 Res1 B-DA = f(B-DA,DBD) I-SID = f(ETH_FP) B-SA C-DA = B-DA C-SA = B-SA OAM PDU Type = 89-02 I-Tagged EC Type 2 OAM Frame B-DA B-SA OAM PDU Type = 89-02 S-Tagged EC Type 2 OAM Frame S-VIDPCP DEI TPID = 88-a8 TPID = 88-E7 I-SIDPCP DEI Res2 0 Res1 B-DA = f(B-DA,DBD) I-SID = S-VID + 4096 C-DA = B-DA C-SA = B-SA B-SA OAM PDU Type = 89-02 I+S-Tagged EC Type 2 OAM Frame S-VIDPCP DEI TPID = 88-a8
11
11 S-Tagged EC Type 2 implications in PB, PBB I, PBB-TE, EOTN networks New UNI-N port is to be specified to support this format Today’s NID devices do not support MAC-in-MAC encapsulation Next gen NID device can include this MAC-in-MAC encapsulation format with S-Tagged EC NNI ports with EC awareness can support this format NNI ports: CNP, PNP, PIP, ONP NNI ports can treat the EC Type 1 and EC Type 2 signals as a single EC signal type; this behaviour is consistent with NNI requirement to be agnostic to the type of client encapsulation
12
12 I+S-Tagged EC Type 2 implications in PB, PBB I, PBB-TE, EOTN networks UNI-N and NNI ports need to distinguish between EC Type 1 and EC Type 2 signals; EC Type 1 and 2 signals require different tagging Tag type to be administered on a per S-VID (EC) basis Violates requirement that NNI is agnostic to client mapping EC Type 1 MEP/MIP will not be able to detect EC Type 2 OAM EC Type 2 MEP/MIP will not be able to detect EC Type 1 OAM New UNI-N port is to be specified to support this format Today’s NID devices do not support MAC-in-MAC encapsulation Next gen NID device can include this MAC-in-MAC encapsulation format with I+S-Tagged EC NNI ports with EC awareness do not support this format CNP, PNP, PIP, ONP need to be extended with I+S-tagging capability, configurable on a per S-VID basis