TI Information – Selective Disclosure Prescalar – Postscalar Open-loop and Closed-loop Settings.

Similar presentations


Presentation on theme: "TI Information – Selective Disclosure Prescalar – Postscalar Open-loop and Closed-loop Settings."— Presentation transcript:

1 TI Information – Selective Disclosure Prescalar – Postscalar Open-loop and Closed-loop Settings

2 TI Information – Selective Disclosure WHY PRES-SCALAR – POST-SCALAR What is it? –Pre-scalar has digital headroom of +24dB without clipping –Post-scalar can be adjusted to the desire distortion for increased power over the full scale input. What is it for? –By increasing the input signal over the full scale (clipped signal) in the pre-scalar block and then adjusting the output the desired distortion in the post-scalar block: The distortion level is independent of PVCC The distortion level is also maintained in post-scalar block, i.e. in a certain range the post-scalar block can be adjusted so that the output amplitude changes but the distortion level stays constant

3 TI Information – Selective Disclosure Closed-loop TAS5710 Prescalar:0x5700AB AAAA Postscalar:0x560002 3333 Input:13 VDC, full scale digital Load:8 Ohm Output:8W, 10% THD+N 1kHz – 8W – 10% THD+N 15kHz – 8W – 10% THD+N

4 TI Information – Selective Disclosure Open-loop TAS5709 Prescalar:0x57002B 0000 Postscalar:0x560006 B000 Input:13 VDC, full scale digital Load:8 Ohm Output:8W, 10% THD+N 1kHz – 8W – 10% THD+N 15kHz – 8W – 10% THD+N