1 Helmut König, Siemens Medical Solutions
Mapping of DICOM SR “Basic Diagnostic Imaging Report” to HL7 CDA R2 “Diagnostic Imaging Report” Helmut König, Siemens Medical Solutions DICOM WG20 / HL7 II SIG March 19, 2007

2 Mapping Scenarios Mapping of the complete constrained DICOM SR “Basic Diagnostic Imaging Report” to an HL7 CDA Release 2 Diagnostic Imaging Report (Receiver optionally selects relevant portions of the transformed document for inclusion into the clinical document) Mapping of a subset of the original DICOM SR “Basic Diagnostic Imaging Report” which includes measurement data and the relevant context information (Specification of minimum context information is essential)

3 DICOM SR to CDA Mapping Scope
Header: Mapping of all DICOM SR Header Modules except for: Specimen Identification (Suppl.122 Work in Progress) Under Discussion: Clinical Trial Modules Patient Study Module Clinical Data (Separate Work Item) Not Covered: Encrypted SR Documents Body: Mapping of DICOM Template 2000 and all the Invoked Sub-Templates (Constraints are specified in Implementation Guide) Large Parts of the Header Mapping (Header Modules) and Body Mapping (Observation Context and Measure-ment Templates) can be reused for other Document Types

4 Basic Diagnostic Imaging Report Templates (1)
Language, Observation Context (Observer, Procedure, Subject)

5 Basic Diagnostic Imaging Report Templates (2)
Measurements (Reuse of HL7 DICOM Composite Object Reference Common Message Element Type Patterns for Image References)

6 SR and CDA Document Structure
Although the SR Document Structure is different from the CDA, the mapping of DICOM SR Content Items and Relationships is Possible Based on Template 2000 (e.g. Content Item CONTAINER to CDA Section, Extraction of textual contents to Narrative Text within CDA Section, Handling of By-Reference Relationships) DICOM SR CDA Release 2

7 Validation of Transcoded CDA “Diagnostic Imaging Report”
XML Schema is Generated from Constrained CDA RMIM for “Diagnostic Imaging Reports” XML Schema may be used fo Header Validation Add-On: Document Body Validation -> Use Schematron

8 Work on “Diagnostic Imaging Report” Implementation Guide: Current Status
Further Work on Mapping Details and Sample Documents Merge Existing Documents WG20 will discuss Open Issues in April (Tcon) and at the Cologne Working Group Meeting in May 2007