1 Overview of the NPDGamma Experiment at the Fundamental Neutron Physics Beamline Geoff Greene UT/ORNL
2
2 Overview FNPB Beamline NPDGamma Experimental Layout Radiological Shielding Magnetic Shielding Issues and Concerns
3
3 Preliminary Design Review Charge Have the hazards been completely identified and accurately classified? Is the design reasonable and does it adequately address identified hazards? In particular, is the conceptual design for the liquid hydrogen system (target, control system, vent stack) capable of leading to an acceptable final design of the system? Are the proposed operational parameters and physical characteristics of the hydrogen target system appropriate for safe operation? Are other aspects of the experiment reasonable and amenable to safe operation?
4
4 FNPB “ Upstream ” Beamline Components Shutter Insert Core Vessel Insert Shutter Gate Core Vessel Flange STARTING POINT neutrons
5
5 Cold Beamline –Guide from 5.5 m to 15 m –Bender out to 7.5 m (R=117 m) Line of sight ends before 2 nd ary shutter –4 chopper housings –Monochromator housing –Secondary Shutter –Beam Monitor & Beam Stop FNPB Cold Neutron Beamline
6
6 Monolith Shielding FNPB Cold Neutron Beamline
7
7 FNP DESIGN OVERVIEW
8
8 FNPB Construction Status 6/07 Project is currently on schedule
9
9 FNPB Shield Wall
10
10 The FNPB Cold Beamline design is essentially complete. Remaining tasks are completion of shielding enclosure detailed design, PPS, and utilities layout. We are NOT explicitly asking for a review of these components. FNPB Cold Beamline Status
11
11 The NPDGamma Experiment Supermirror polarizer FNPB guide CsI Detector Array Liquid H 2 Target H 2 Vent Line Beam Stop Magnetic Field Coils Magnetic Shielding H 2 Manifold Enclosure
12
12 The NPDGamma Experiment – Vent System
13
13 The NPDGamma Experiment – Shield Roof and Mezzanine
14
14 The NPDGamma Experiment – Vent Line Routing
15
15 Radiological Shielding NOTE: Because of curved guide and use of 6 Li collimation, dose rates are totally dominated by photons by cold neutron capture.* Shielding enclosure: 18” Concrete shared wall with FP 12 9” Concrete wall on FP 14 side 9” Concrete roof Enclosure is lined with Steel (up to 2” in places) Additional “temporary” shielding blocks are placed on FP14 of Wall *This is validated by MCNPX simulaltions.
16
16 MCNPX Radiation Simulations
17
17 MCNPX Radiation Simulations
18
18 Magnetic Fields The NPDGamma magnetic field is low (10 Gauss) but occupies a large volume. The shielding enclosure is lined with 0.25”-0.75” of 1010 steel to act as a flux return. This also serves to provide magnetic shielding and to confine stray magnetic fields. We used commercial magnetic FEA software (OPERA3D) to model our magnetic field arrangement. Facility requirements call for magnetic field to be less than 50mGauss at the boundary of adjacent beamlines
19
19 Stray Magnetic Fields -Summary The NPDGamma external magnetic field is below the facility required level at the FP12 boundary and the FP15 boundary. It slightly exceeds the required level at the FP14 boundary. This is acceptable to FP14 beamline responsibles. E F 90. 8 152.2 348 359.2 CoilsCoils Magnetic shield Z 182.6 8 Concrete wall 1 X 331.65 788.72 303.83 30.5 A B 440.72 13 3 22 5 2 FP 12 side FP 14 side
20
20 Other Issues A detailed hazard screening (next presentation) has identified the liquid Hydrogen target as the only “exceptional” operational issue. All other hazards are similar to those encountered on other SNS instruments. The details of the LH2 target and vent system are the subject of the third presentation.