Presentation is loading. Please wait.

Presentation is loading. Please wait.

ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -

Similar presentations


Presentation on theme: "ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -"— Presentation transcript:

1 ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -
ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION I - GAS DETECTORS I I - OPACIMETERS III - ANEMOMETERS Fives Driving Progress Fives Pillard

2 VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL
Anemometers Burner Ignitor's tube Opacimeters/ Dust monitors Gas detector Smoke detector Fives Pillard

3 TUNNEL DEPARTMENT III- ANEMOMETERS
Fives Driving Progress Fives Pillard 3 3

4 WINDCHECK: VELOCITY MEASUREMENT
4

5 OPERATING PRINCIPLE WINDCHECK 5 View Technology Type of measure Safety
Sound propagation: Measuring the displacement of an ultrasonic wave Type of measure Velocity and direction of the wind in a road tunnel Safety Strategic function with ventilation system Sensors 2 transducers are alternately transmitters and receivers Value Meter by second Fives Pillard 5

6 TECHNICAL SPECIFICATIONS WINDCHECK
SENSOR Velocity range - 20 to +20 m/s Velocity resolution 0.1 m/s Velocity accuracy 0.5% Wind direction Bi-directionnal Temperature range - 40 to +60°c (up to +120°) Temperature resolution 0.1°C Temperature accuracy +/- 1°C GENERAL CHARACTERISTICS Operating Temperature - 40 to +70°c (up to 120 °) Electric supply 24 VDC -15%/+10% Power consumption 3 W Analogue output signal 4-20mA / Fault < 4mA Digital output yes Protection rating IP66 Dimensions 310 X 120 X 300 mm (housing + sensor) OPASTOP CONSOLE Display LCD Controls 4 push-buttons Connection Cable 4/20mA 6

7 WEIGHT, SIZE & DIMENSIONS
Weight = 2 kg 7

8 Electrical connection
ELECTRICAL SUPPLY WIND: 4-20mA OUTPUT SIGNAL Connector Designation +24V Positive 24V terminal 0V Negative 24V terminal NC Earth Wind 4-20 mA connector Designation + Positive terminal of the 4-20mA loop GND Negative terminal of the 4-20mA loop TEMPERATURE: 4-20mA OUTPUT SIGNAL Temperature 4-20 mA connector Designation + Positive terminal of the 4-20mA loop GND Negative terminal of the 4-20mA loop 8

9 ACCESSORIES, OPTIONS, SERVICES
Maintenance LC3 console Services for testing, assistance with commissioning, annual maintenance contract etc…. 9

10 VIEW OF FITTED PRODUCT Fives Pillard 10

11 Integrated temperature measurement
WINDCHECK anemometer No moving parts Unaffected by gyroscopic effects at low wind speed Integrated temperature measurement Auto-diagnostic and automatic fault correction No calibration Protection IP66 Setting by infra red remote control Only maintenance: wet cleaning of the 2 tranducers

12 Thank you! Fives Driving Progress Fives Pillard 12 12


Download ppt "ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -"