Download presentation
Published byThomasina Atkins Modified over 9 years ago
1
Single Loop Analogue addressable fire control Panel
2
Single Loop Fire Control Panel
1 Loop not expandable Panel Certified according to EN54-4 ed EN54-2 by IMQ Up to 240 devices on the Loop LCD Graphic display Navigation keys System status leds 1 Extinguish channel optional card (certified according EN ) Low Cost
3
Single Loop Fire Control Panel
New generation technology, software selectable protocol Up to 240 devices on the Loop Self addressing feature Up to 2000 m loop length Open Line or Loop selectable Loop diagnostic feature (detectors contamination level, Loop signal quality, real time value) Each device equiped with a short circuit Isolator
4
Single Loop Fire Control Panel
30 Zones 1,4 A Switching Power supply Thermal compensated battery charger Battery supervision (efficiency check)
5
Single Loop Fire Control Panel
RS232 port for UP/Downloading Self restorable fuses protect outputs and battery Battery disconnection in case of deep discharge 24V Output for external devices feed Supervised Dialer Output 1 A Supervised Alarm Output 1 Supervised + 1 dry contact fault output RS485 BUS for up to 4 repeater connection. On each repeater event view and scroll, reset silence etc.
6
Single Loop Fire Control Panel
Using the LCD Graphic display the start up and all the requested programming can be easily done from the front panel
7
Single Loop Fire Control Panel
Using PC Software a clear indication of Loop devices which report the exact connection sequence is available With a double click device’s parameters can be accessed
8
Single Loop Fire Control Panel
Real Time monitor of each device state is available where a wide range of information are reported
9
Single Loop Fire Control Panel
Up to 8 timers with yearly programming are available
10
Single Loop Fire Control Panel
Logic equation definable by installer to fulfill each installation requirement
11
Single Loop Fire Control Panel
SMARTLetLoose/ONE Optional Card for single channel extinguish system management
12
Single Loop Fire Control Panel
CPD EN Approved
13
Single Loop Fire Control Panel
1 supervised input for manual release 1 supervised input for stop release 1 supervised input for pressure switch for baloon supervision and release confirm 1 supervised output for Pre Extinguish signalling 1 supervised output for released signalling
14
Single Loop Fire Control Panel
SmartLight/G : Up to 240 loop devices, 30 Zones SmartLight/S : up to 64 loop devices, 16 zones SmartLetLoose/ONE : single channel gas extinguish management card