J-PARC: Where is it?
3
J-PARC (Japan Proton Accelerator Research Complex) Tokai, Japan 50 GeV Synchrotron (15 A) 400 MeV Linac (350m) 3 GeV Synchrotron (333 A) Material and Biological Science Facility World-highest beam intensity : ~1 MW x10 of BNL-AGS, x100 of KEK-PS Neutrino Facility
4
Nuclear & Hadron Physics in J-PARC
5
J-PARC Hadron Hall Handron Hall Beam Dump K1.8 K1.8BR K1.1 K1.1BR 30~50 GeV primary beam Production target (T1) Strangeness nuclear physics at K1.8BR and K1.8 spectroscopy of hypernuclei n-rich hypernuclei hypernuclei hypernuclei -atomic X rays search Weak decays of hypernuclei K - nucleus bound states Pion double charge exchange nucleus YN scattering K - nucleus bound states K - atomic X rays nucleus nucleus Hyperon resonances approved / proposed (incl. LOI) High Mom. Line study spectroscopy of hyp. hypernuclei hypernuclei KL Hadron mass in nuclei Nucleon quark structure meson structure
6
June, 2007
8
Dec, 2008
9
K1.8 Beam Line High intensity: 1.4x10 6 K /spill (Phase-1) High purity: K / ~6.9 Proton beam 30GeV-9 A 1.8 GeV/c K beam
10
K1.8 beamline Design of K1.8 beam line Double stage E.S. Separators MS2(V) MS1(Vertical Slit) Mom(Horizontal slit) IFV(V) IFV(H) Beam analyzer (dp/p~10 -4 ) Primary proton beam (protons/spill) 30 GeV-9 A 2.0E+14 Length (m)45.853 Acceptance (msr.%)1.4 K ( intensity (ppp) @1.8 GeV/c 1.4E+06 @1.5 GeV/c0.54E+06 @1.1 GeV/c0.08E+06 Electrostatic separators750kV/10cm, 6m×2 Single rate @ MS2 @ 1.8 GeV/c > 8E+06 K /( + ) @ FF @ 1.8 GeV/c 3.5 X/Y(rms) size @ FF (mm)19.8/3.2
11
Apr, 2010 K1.8 beamline
12
SKS Spectrometer High resolution: – p/p ~0.1% – Mass resolution: ~ 2 MeV (FWHM) Large acceptance – 100 msr, up to ~1GeV/c Variations for high mom. – SKS-Plus Keeping resolution – SKS-Minus Keeping acceptance 2.7T(395A) ~1.5T
13
Brief History & Status Construction completed in July 2009 First beam in September – Beam Line commissioning with intermittent beam time – Concurrent with accelerator commissioning All components were found to work well Beam intensity and structure is the current issue First Physics beam time in Nov. 2010 – E19 experiment ( search)
14
Beam Conditions Beam intensity: ~ 3.5 x 10 12 protons per 6 second cycle – ~1% of the design. Still, higher than KEK-PS – x3 intensity demonstrated – Pion intensity: > 10 7 /s possible. Limited by detectors. Kaon is clearly seen – Purity is to be improved (low sep. voltage) # of K - ~25 k/cycle consistent K - /π - ratio ~ 0.14 π-π- K-K- Preliminary
15
Beam microstructure Instantaneous intensity >> average intensity – Limiting the available intensity due to detector pileup – We ran at 1.1 M /spill (2.2s) Instantaneous rate: ~10 MHz – Gradually improving
16
E19 Experiment Mysteries about Pentaquark, Does it really exist? – Confirmation with good sensitivity is crucial Width? Why so narrow? – Certainly < 1MeV – No bump in K + n K + n, K 0 p Spin & parity? – 1/2 + ? 3/2 + ? 1/2 - ?... Its nature? – KN? K N?...
17
High resolution search. Why? For good S/N ratio – is above KN threshold, and is NEVER BG free – High resolution really helps to achieve good S/N ratio crucial for good sensitivity Width measurement – Almost certainly, < 1 MeV – Similar or better resolution necessary! Typical resolution so far ~ 10 MeV – No high resolution search – There is a good chance for high resolution experiments. Missing mass spectroscopy
18
p( ,K ) reaction: KEK-PS E522 Miwa et al. PLB635 (2006) 72. Poor resolution ~13 MeV (FWHM) Low statistics: < 10 10 on target Still, there was a hint of peak: 1.9 b/sr 2.5 significance Statistics: x100 Resolution: x1/5
19
Actual Run in Oct./Nov. Beam time: 156 hours – +116 hours for commissioning and calibration Total statistics: 7.8 x 10 10 pions on target – ~5% of the proposal
20
Test data: p( ,K ) Good mass resolution: 1.9 MeV (FWHM) achieved Cross section OK Good performance confirmed
21
Preliminary result No peak Upper limit for a peak ~0.4 b/sr (very preliminary) c.f. 3.9 b/sr in E522 “hint” ruled out
22
Summary Physics experiment in K1.8 beam line has just started! All detectors are working very well. Beam intensity & structure is the current issue – Intensity: ~1% of design, still enough for pions – Structure limits the available intensity to ~1 MHz – Improving with efforts of accelerator group E19: search in p( ,K ) reaction – Detector performances are very good – No peak observed – Upper limit ~0.4 b/sr Ruled out the “hint” in previous KEK-PS E522 spectrum – We will take more data in the coming runs
23
Future prospects The next beam time is scheduled in Apr. 2011 – We will continue to run E19 and E27 – Improvement of beam structure expected Another beam time expected in autumn 2011 – Beam intensity: 1 x 10 13 /cycle (3% of design) expected – E10, E13 (E19) will run, and E05 will take pilot data. More exciting experiments are waiting!