Download presentation
Presentation is loading. Please wait.
Published byEmerald Goodwin Modified over 9 years ago
1
Preprocessing of FMRI Data fMRI Graduate Course October 23, 2002
2
What is preprocessing? Correcting for non-task-related variability in experimental data –Usually done without consideration of experimental design; thus, pre-analysis –Occasionally called post-processing, in reference to being after acquisition Attempts to remove, rather than model, data variability
3
Signal, noise, and the General Linear Model Measured Data Amplitude (solve for) Design Model Noise Cf. Boynton et al., 1996
4
Signal-Noise-Ratio (SNR) Task-Related Variability Non-task-related Variability
5
Preprocessing Steps Slice Timing Correction Motion Correction Coregistration Normalization Spatial Smoothing Segmentation Region of Interest Identification
6
Tools for Preprocessing SPM Brain Voyager VoxBo AFNI Custom BIAC scripts (Favorini, McKeown)
7
Slice Timing Correction
8
Why do we correct for slice timing? Corrects for differences in acquisition time within a TR –Especially important for long TRs (where expected HDR amplitude may vary significantly) –Accuracy of interpolation also decreases with increasing TR When should it be done? –Before motion correction: interpolates data from (potentially) different voxels Better for interleaved acquisition –After motion correction: changes in slice of voxels results in changes in time within TR Better for sequential acquisition
9
Effects of uncorrected slice timing Base Hemodynamic Response Base HDR + Noise Base HDR + Slice Timing Errors Base HDR + Noise + Slice Timing Errors
10
Base HDR: 2s TR
11
Base HDR + Noise r = 0.77 r = 0.80 r = 0.81
12
Base HDR + Slice Timing Errors r = 0.85 r = 0.92 r = 0.62
13
HDR + Noise + Slice Timing r = 0.65 r = 0.67 r = 0.19
14
Interpolation Strategies Linear interpolation Spline interpolation Sinc interpolation
15
Motion Correction
16
Head Motion: Good and Bad
17
Correcting Head Motion Rigid body transformation –6 parameters: 3 translation, 3 rotation Minimization of some cost function –E.g., sum of squared differences
18
Simulated Head Motion
19
Severe Head Motion: Simulation Two 4s movements of 8mm in -Y direction (during task epochs) Motion
20
Severe Head Motion: Real Data Two 4s movements of 8mm in –Y direction (during task epochs) Motion
21
Effects of Head Motion Correction
22
Limitations of Motion Correction Artifact-related limitations –Loss of data at edges of imaging volume –Ghosts in image do not change in same manner as real data Distortions in fMRI images –Distortions may be dependent on position in field, not position in head Intrinsic problems with correction of both slice timing and head motion
23
Coregistration
24
Should you Coregister? Advantages –Aids in normalization –Allows display of activation on anatomical images –Allows comparison across modalities –Necessary if no coplanar anatomical images Disadvantages –May severely distort functional data –May reduce correspondence between functional and anatomical images
25
Normalization
26
Standardized Spaces Talairach space (proportional grid system) –From atlas of Talairach and Tournoux (1988) –Based on single subject (60y, Female, Cadaver) –Single hemisphere –Related to Brodmann coordinates Montreal Neurological Institute (MNI) space –Combination of many MRI scans on normal controls All right-handed subjects –Approximated to Talaraich space Slightly larger Taller from AC to top by 5mm; deeper from AC to bottom by 10mm –Used by SPM, National fMRI Database, International Consortium for Brain Mapping
27
Normalization to Template Normalization TemplateNormalized Data
28
Anterior and Posterior Commissures Anterior Commissure Posterior Commissure
29
Should you normalize? Advantages –Allows generalization of results to larger population –Improves comparison with other studies –Provides coordinate space for reporting results –Enables averaging across subjects Disadvantages –Reduces spatial resolution –May reduce activation strength by subject averaging –Time consuming, potentially problematic Doing bad normalization is much worse than not normalizing
30
Slice-Based Normalization Before Adjustment (15 Subjects) After Adjustment to Reference Image Registration courtesy Dr. Martin McKeown (BIAC)
31
Spatial Smoothing
32
Techniques for Smoothing Application of Gaussian kernel –Usually expressed in #mm FWHM –“Full Width – Half Maximum” –Typically ~2 times voxel size
33
Effects of Smoothing on Activity Unsmoothed Data Smoothed Data (kernel width 5 voxels)
34
Should you spatially smooth? Advantages –Increases Signal to Noise Ratio (SNR) Matched Filter Theorem: Maximum increase in SNR by filter with same shape/size as signal –Reduces number of comparisons Allows application of Gaussian Field Theory –May improve comparisons across subjects Signal may be spread widely across cortex, due to intersubject variability Disadvantages –Reduces spatial resolution –Challenging to smooth accurately if size/shape of signal is not known
35
Segmentation Classifies voxels within an image into different anatomical divisions –Gray Matter –White Matter –Cerebro-spinal Fluid (CSF) Image courtesy J. Bizzell & A. Belger
36
Histogram of Voxel Intensities
37
Region of Interest Drawing
38
Why use an ROI-based approach? Allows direct, unbiased measurement of activity in an anatomical region –Assumes functional divisions tend to follow anatomical divisions Improves ability to identify topographic changes –Motor mapping (central sulcus) –Social perception mapping (superior temporal sulcus) Complements voxel-based analyses
39
Drawing ROIs Drawing Tools –BIAC software (e.g., Overlay2) –Analyze –IRIS/SNAP (G. Gerig) Reference Works –Print atlases –Online atlases Analysis Tools –roi_analysis_script.m
40
ROI Examples
41
BIAC is studying biological motion and social perception – here by determining how context modulates brain activity in elicited when a subject watches a character shift gaze toward or away from a target.
42
Additional Resources SPM website –Course Notes http://www.fil.ion.ucl.ac.uk/spm/course/notes01.ht ml –Instructions Brain viewers –http://www.bic.mni.mcgill.ca/cgi/icbm_view/
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.