1 Unitronics 2009

2 Review Hardware Review Software & Utilities Jazz® Series M91 Series
Vision120™ Series Vision130™ Series Vision Graphic/Touch OPLC Color Vision Software & Utilities

3 Review Hardware Review Software & Utilities

4 Jazz® Micro OPLCTM Key Points: Two line display Real Keypad for
Data entry Modbus and open protocol communication SMS/ cellular connection Auto-tune PID, up to 4 loops Full project upload Low cost

5 Jazz® Micro OPLCTM 9 models of JazzTM OPLC JZ10-11-R10 – 6 DI, 4 RO
JZ10-11-T10 – 6 DI, 4 TO JZ10-11-R16 – 6 DI, 2 D or A (0-10V) inputs, 2 AI (0/4-20 mA), 6 RO JZ10-11-T17 – 6 DI, 2 D or A (0-10V) inputs, 2 AI (0/4-20 mA), 7 TO JZ10-11-R31 – 16 DI, 2 D or A (0-10V) inputs, 2AI (0/4-20 mA), 11 RO JZ10-11-T40 – 16 DI, 2 D or A (0-10V) inputs, 2 AI (0/4-20 mA), 20 TO JZ10-11-PT15- 3 DI, 3 D or A inputs, 3 PT1000/NI1000 inputs, 5 RO and 1 TO (HSO) JZ10-11-UN20 – 9 DI, 2 D or A (0-10V) inputs, 1 AI (0/4-20 mA), 1 PT100/TC inputs, 5 RO, 2 TO JZ10-11-UA24 – 9 DI, 2 D or A (0-10V) inputs, 2 AI (0/4-20 mA), 2 PT100/TC inputs, 5 RO, 2 TO, 2 Analog Outputs

6 M91 Micro OPLCTM Key Points: Two line display
Real Keypad for Data entry Modbus & open protocol communication SMS via GSM communication Full project upload Auto-tune PID, up to 4 loops Expandable Small Data Base (1024 registers) Low cost

7 M91 Micro OPLCTM 10 models of the M91 OPLC
M91-2-R DI, 1 AI , 6 RO M91-2-R2C - 10 DI, 2 AI , 6 RO M91-2-R DI, 2 A/D I, 12 RO M91-2-R6C - 6 DI, 6 AI, 1HSI, 6 RO M91-2-RA DI, 2 A/D I 14 bit +2 TC/PT100, 2 AO 12 bit, 8 RO M91-2-T DI, 12 TO M91-2-T2C - 10 DI, 2 A/D I , 12 TO M91-2-T DI, 16 TO M91-2-UN DI, 2 A/D/TC/PT100 Inputs (14 bit) , 12 TO M91-2-UA DI, 2 A/D/TC/PT100 Inputs, 12 bits, 2 AO 12 bits , 10 TO

8 Vision120TM Graphic OPLCTM
Key Points: Graphic display 128x64 Real Keypad for Data entry Application size of 448K 2 serial ports RS232/485 Modbus and open protocol communication Supports CANopen SMS/cellular connection-GSM/GPRS Full project upload Expandable Data Table

9 Vision120TM Graphic OPLCTM

10 Vision120TM Graphic OPLCTM
10 models of the V120 OPLC V R DI, 1 AI , 6 RO V R2C - 10 DI, 2 AI , 6 RO V R DI, 2 A/D I, 12 RO V R6C - 6 DI, 6 AI, 1HSI, 6 RO V RA DI, 2 A/D I 14 bit +2 TC/PT100, 2 AO 12 bit, 8 RO V T DI, 12 TO V T2C - 10 DI, 2 A/D I , 12 TO V T DI, 16 TO V UN DI, 2 A/D/TC/PT100 Inputs (14 bit) , 12 TO V UA DI, 2 A/D/TC/PT100 Inputs, 12 bits, 2 AO 12 bits , 10 TO

11 Vision130TM Graphic OPLCTM

12 Vision130TM Graphic OPLCTM
Key Points: Graphic display 128x64, 2.4" Real Keypad for Data entry Application size of 512K; 20µsec per 1K 1 build in serial ports RS232/485 Option for a second port RS232/485 or Ethernet Modbus and open protocol communication serial and over IP Supports CANopen (CANbus as an add on module) GPRS/GSM/CDMA enabled Full project upload Expandable Data Table, Text string library

13 Vision130TM Graphic OPLCTM
9 models of the V130 OPLC V R DI, 2 A/D I, 6 RO V R DI, 2 A/D I, 12 RO V RA DI, 2 A/D I 14 bit +2 TC/PT100, 2 AO 12 bit , 8 RO V T DI, 2 A/D I, 3HSI and 7 HSO , 12 TO V T DI, 2 A/D I, 3HSI and 7 HSO, 16 TO V TA DI, 2 A/D I 14 bits +2 TC/PT100, 2 AO 12 bits, 1HSI 5 HSO , 10 TO V R6 – 6 DI, 2 A/D I, 4 AI, 1HSI, 6 RO V TRA DI, 2AI, 2 PT100/TC, 1HSC, 4 RO, 2 AO, 4 HSO. V TR DI, 2 AI, 3 HSC, 8RO, 4 HSO.

14 VisionTM Graphic/Touch OPLCTM (V230/260/280/290/530)

15 VisionTM Graphic/Touch OPLCTM (V230/260/280/290/530)
Key Points: Graphic display 128x64 to 320x240; 3.2” – 5.7” Real Keypad for Data entry/virtual keyboard on the touch Application size of 1MB; 30µsec per 1K 2 build in serial ports RS232 Option for a 3rd port RS232/485 or Ethernet Supports CANopen GPRS/GSM/CDMA enabled Full project upload Expandable Data Table Modbus and open protocol communication

16 VisionTM Graphic/Touch OPLCTM (V230/260/280/290/530)

17 VisionTM Graphic/Touch OPLCTM (V230/260/280/290/530)
Expansions EX-A1-expansion adapter IO-DI8-TO8 IO-DI16 IO-TO16 IO-DI8-RO4 IO-RO8 IO-RO16 IO-DI8ACH EX90-DI8-RO8 Fast response IO-AI4-AO2 IO-AO6X IO-ATC8 IO-LC1/3 IO-PT400 IO-PT4K

18 VisionTM Graphic/Touch OPLCTM (V230/260/280/290/530)
Snap-in I/Os 6 Snap-in models: V E1B V E2B V E3XB V E4XB V E5B V E6B

19 EX-RC1- Remote IO Adapter
The EX-RC1 enables you to remotely locate I/Os up to 1 kilometer from a PLC. You can include both PLCs and adapters on the UniCAN network, up to a total of 60 nodes. Up to 8 I/O modules can be connected to a single adapter.

20 XL Expansion Modules EX-D16A3-RO8 / TO16
24 VDC 16 Digital Inputs PNP/NPN, including 1 HS Counters 3 Analog Inputs 15 PNP+ 1 PNP/NPN Transistor Outputs,1 HSO Or 8 Relay output (model EX-D16A3-RO8) IO D16A3-RO16 / TO16 24 VDC 16 Digital Inputs PNP/NPN, including 2 HS Counters 3 Analog Inputs 16 Relay/Transistor Outputs

21 VisionTM Color OPLCTM

22 VisionTM Color OPLCTM Vision350TM - The first 3.5“ color
Touch screen OPLC on the market Digital, Analog and PT100/TC inputs, Digital and Analog outputs Application size of 1MB, 15µsec per 1K Supports CANopen Ethernet option QVGA color TFT display Support Micro SD

23 VisionTM Color OPLCTM 9 models of the Vision 350TM OPLC
V R DI, 2 A/D I, 6 RO V R DI, 2 A/D I, 12 RO V RA DI, 2 A/D I 14 bit +2 TC/PT100, 2 AO 12 bit , 8 RO V T DI, 2 A/D I, 3HSI and 7 HSO , 12 TO V T DI, 2 A/D I, 2 HSI and 7 HSO, 16 TO V TA DI, 2 A/D I 14 bits +2 TC/PT100, 2 AO 12 bits, 1HSI 5 HSO , 10 TO V R6 – 6 DI, 2 A/D I, 4 AI, 1HSI, 6 RO V TRA DI, 2AI, 2 PT100/TC, 1HSC, 4 RO, 2 AO, 4 HSO. V TR DI, 2 AI, 3 HSC, 8RO, 4 HSO.

24 V130 & V350 with TRA22 or TR34 I/O board
HSC / Shaft Encoder V130 & V350 with TRA22 or TR34 I/O board Push-Pull PNP/NPN Driver Type 200 kHz Max 100 kHz Max HSC 50 kHz Max Shaft encoder High Speed NPN Transistor output: Frequency Range kHz Support PTO

25 VisionTM Color OPLCTM Vision570TM - And much more…
5.7“ color Touch screen OPLC plus Snap-in & expansion I/Os TFT Color Graphic display, QVGA Application size of 2MB; 9µsec per 1K 2 build in serial ports RS232/485 Option for a 3rd port RS232/485 or Ethernet Modbus and open protocol communication serial or over IP Build in Alarms, string library and trends tasks CANopen Support SD Support Web server capabilities And much more…

26 The New V570 model with built in I/O
VisionTM Color OPLCTM The New V570 model with built in I/O V T34 : 16 DI (Isolated), 2 HSC / Shaft Encoder, 2 AI, 16 TO (Isolated)

27 Review About Unitronics Hardware Review Software & Utilities

28 Software - programming environment
M91 and Jazz are programmed using the U90Ladder All Vision products are programmed using the Visilogic In order to ensure Backwards compatibility Unitronics provides also the Version swapper

29 Software Utilities - Remote Access
A tool that the machine builder/system integrator can give his customer as an added value for its selection to work with Unitronics’ products Using Remote Access one can access the displays of the PLC, operand values, data tables and even download using the UniDownloader

30 Software Utilities - DataXport
DataXport is a server based application that allows to retrieve the data stored at the data tables of the PLC using different communication methods and based on automatic process

31 Software Utilities - Communication
DDE/OPC gives a standard way to connect to the Unitronics OPLC using any SCADA or other Windows based application

32 Software Utilities – SD Suite
SD Suite Use SD Suite to format an SD card to be compatible with Unitronics OPLC, and to Access,convert, read, and export the content of files that a Unitronics OPLC creates on a SD card.

33 Software Utilities – Remote Operator
Remote Operator - Enables you to use a PC to view and work with several remote controller's HMI panel at the same time.

34 Software Utilities – UniDownloader
UniDownloader - Enables you to download complete applications to local or remote controllers. These applications are in compressed .udc format.

35 Thank you


Download ppt "Unitronics 2009."