Presentation is loading. Please wait.

Presentation is loading. Please wait.

Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.

Similar presentations


Presentation on theme: "Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview."— Presentation transcript:

1 Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview

2 Schutzvermerk nach DIN 34 beachten High performance PLC with IT-Functions in compact design XControl XC200

3 Schutzvermerk nach DIN 34 beachten CAN Ethernet CAN Profibus DP XC100 XC200 XC600 Memory Processing speed 128K (256K) 0,5ms/K 512K 0,05ms/K 8MB 0,02ms/K XC200: The compact high performance machine controller

4 Schutzvermerk nach DIN 34 beachten Data logger for QM or production data on MC, access directly via Ethernet Fast PLC in compact design 0,04ms/K 2 integr. Counters 2 Interrupt inputs Gateway CAN -Ethernet Solves positioning tasks with integrated incremental decoder Ethernet MMC Ethernet QS Specialities

5 Schutzvermerk nach DIN 34 beachten - Compact PLC for machine builders - Assembly on hat rail - Power supply 24V DC - Elements for display and operation - Real time clock - Memory card for data backup, recipe handling and Data logging Features (1)

6 Schutzvermerk nach DIN 34 beachten - Two memory sizes - 256K/128K memory for user-program/-data - 512K/ 256K memory for user-program/-data - RS232 Programming interface -10/100MBit Ethernet interface for programming, network data communication or service access -Onboard local I/O - CANopen fieldbus interface - Battery for data buffering and real time clock - High processing speed - 32 Bit Processor with 0,04 ms/K instructions Features (2)

7 Schutzvermerk nach DIN 34 beachten Display PLC status: Run / Stop, SF Operation mode switch : Run / Stop Status display local I/O LEDs Local I/O 8 DI24 VDC - 2 Interrupt - 2 Counter - 1 incremental encoder 6 DO 24 VDC Battery for retentive data and real time clock CAN-interface Plugable, with integrated T-connector (connection via cage clamps) _Interface slot for Multi-Media-memory cards RS232/Ethernet Programming / communication (RJ45-socket) USB-interface Operating / display elements

8 Schutzvermerk nach DIN 34 beachten 0, 1, 2, 3,........., 13, 14, 15 Flexible connectivity: - Pluggable terminals - tension cage clamp or screw Digital inputs / outputs - 24VDC 8, 16 and 32 point I/Q - 24VDC configurable (4DI, 12 DI/DO, 4DO as 2A) - 230VAC 16 DI Analog inputs / outputs -Current, Voltage, Temperature up to 8 channels per module -Fast (1ms) 2AI-1AO or 4AI-2AO Many technology modules Counters, Incremental encoder inputs, Communication Generous extensibility: - Up to 15 XI/OC modules, only 510mm wide - Max. 494 digital I/O (15 * 32 +14) - Max. 40 Analog I/O (at present max 5 modules due to max. power consumption) Locale I/O extension

9 Schutzvermerk nach DIN 34 beachten XC200 as CAN slave XC200 as CAN master CANOpen fieldbus master - up to 500 KBaud - Also usable as slave - SDO communication - Programmable via CAN - Simple data exchange between controllers via network variables -cyclic -Event triggered CANopen networking with XC200 XC200 in Multimaster configuration

10 Schutzvermerk nach DIN 34 beachten 10/100MBit Ethernet - Network communication with network global variables -Cyclic -Event triggered -Data communication via UDP telegrams -Between controllers -To PC applications -To all devices with Ethernet interface ETHERNET Ethernet networking with XC200

11 Schutzvermerk nach DIN 34 beachten Access via OPC Visualisation EXCEL Visual Basic Data exchange via OPC Access to all process variables Connection to all standard SCADA packages Connection to Office applications (EXCEL,..) Connection to user-created WINDOWS applications (Visual Basic,...) ETHERNET OPC Client XSoft OPC Server Open interfaces

12 Schutzvermerk nach DIN 34 beachten Extremely powerful and fast machine control with very compact dimensions Saving of large amounts of data on MultiMediaCard A powerful IEC- Software package for all XControl PLCs Very good Expandability Locally up to 15 modules Decentrally via integrated CANopen interface OPC Server supports direct connection to all OPC client applications Fast 100MBit/s Ethernet interface Web Server for easy data access with standard WEB browsers USB interface for attaching printers and external memory XControl XC200: Summary