Download presentation
Presentation is loading. Please wait.
Published byLee Lawson Modified over 9 years ago
1
Filtration at the Bloomington, IL Water Treatment Plant
2
Old Plant Filters 1929, 1956, 1966
3
Old Plant Filters Filters #1-12: GAC-Capped Sand 435 square feet per filter (20’ x 21.75’) Operated at a flow rate of ~ 1 gpm/ft 2 Fixed surface wash nozzles
4
Old Plant Filters: Influent Trough
5
Old Plant Filters After Pressure Washing PVC Surface Wash Piping
6
Old Plant Filters: Fixed Surface Wash Nozzles PVC Pipe and Nozzles
7
Old Plant Filters: Media Removed Manifold Laterals
8
Old Plant Filters: Underdrain Perforated Cast Iron Lateral Piping : Uniform Distribution of Backwash Water
9
New Plant Filters - 1994
10
New Plant Filters: GAC Cap 24” filter cap replaced with virgin GAC every two years
11
New Plant Filters: Influent Trough Wash Water Trough Influent Channel and Wash Water Gullet
12
New Plant Filters: Influent Trough Filters #13-18 Dual-cell filters 462 square feet per filter (10.75’ x 21.5’ x 2 cells) Operated at a flow rate of ~ 2 gpm/ft 2 Rotating surface wash
13
New Plant Filters: Rotating Surface Wash Surface Wash Header
14
New Plant Filters GAC Removed Sand Layer Exposed
15
Granular Activated Carbon and Silica Sand
16
Backwash
17
Sand Grab Sample
18
Filter Core Sample Silica Sand Granular Activated Carbon
19
Top / Bottom of Sand Layer topbottom
20
New / Old Sand New sand is finer; more uniform
21
New / Old Sand D 10 (new) = 0.52 mm D 10 (old) = 0.58 mm
22
Examination of Old Sand Stereo Microscope
23
Examination of Old Sand
27
Elution of Old Sand
28
Organisms Rinsed from Old Sand
29
GAC Grab Sample
30
Chain of Custody
31
New / Old Carbon newold blackgrey
32
New / Old Carbon Old GAC has lost both ‘fines’ & larger particles
33
Examination of Old Carbon
36
Examination of Old Carbon Stalked, Epiphytic Bacteria extend from GAC surface
37
Examination of Old Carbon Bacteria fluoresce under UV illumination
38
Examination of Old Carbon Microbial Colonization of GAC Surface
39
Examination of Old Carbon
42
Replacing Lost Sand
43
The Changing of the Carbon
44
Disinfection after GAC/Sand Replacement