Presentation is loading. Please wait.

Presentation is loading. Please wait.

External perimeter protection Active Infra Red Motion sensors

Similar presentations


Presentation on theme: "External perimeter protection Active Infra Red Motion sensors"— Presentation transcript:

1 External perimeter protection Active Infra Red Motion sensors
Farshid Ossareh December 2004

2 1 – Beginning: The audience challenge
principle Theory Working Switching Visibility Fog discrimination 1 – Beginning: The audience challenge

3 SB series use the active infra red light
950 nm 400 nm 500 nm 700 nm 600 nm 5µm Near infrared Far infrared Ultraviolet V i s i b l e L i g h t ACTIVE Infra Red PASSIVE Infra Red TYPE of the detector >>>> SB series use the active infra red light

4 Working principle Invisible IR signal beams between transmitter and reciever over a protected distance Transmitter Reciever

5 Working principle Transmitter Reciever Transmitter send a light signal which is invisible to human (infrared signal wave of 900nm). Reciever act as a elctronic eye, analyze the amplitude of the signal send by transmitter

6 Working principle Not sensitive to rain
Transmitter Reciever Not sensitive to rain Not sensitive to any movement doesn’t cut the beams Not sensitive to EM wave and signals

7 Communication principle
Pulsed beams and selectable channels Ch1 Ch2 Ch3 Ch4 Channels are made by pulse frequency Rec Trans Receiver on ch1 will only see the Transmitter on ch1 & … Ch 1 Ch1 Ch 2

8 Switching principle SB250 / SB2100
Communication princple: Pulsed beams and selectable channels Rotection zone is about 20cm Both beams needs to be intruppted to trigger the alarm

9 Switching principle SB450 / SB4100 / SB4200
Communication princple: Pulsed beams and selectable channels Rotection zone is about 40cm Both beams needs to be intruppted to trigger the alarm

10 Visibilty diagram AIR Range
Geneal rule: the range is equal to visibilty on site. The SB series range Theoretical max range: 2550m When the visibility is 200m, the range will be 200m When the visibility is 60m (fog), the range will be 60m AIR Range 200m 100m 50m If the average visibility during the normal fog is 80m, it is recommended not to install a 100 or 200m product. 80m 50m m m Visibility

11 Fog dectection Receiver analyse the signal power

12 Fog dectection When the signal amplitude at the reciever reaches the minimun level the disqualification relay will be triggered,

13 Spec. Feature If the alarm relays are connected in serie and there is a steady obstruction, the AIR beam will release the alarm relay and trigger disqualication relay. Alarm relay (NC) Max 60 s Disq relay (NO)

14 1 – Beginning: The audience challenge
2 Range Selection Modular beams Modular pillars 1 – Beginning: The audience challenge

15 How to select the products
On price Perception to detection Perimeter Detection Low risk Perimeters high walls Perimeters rond the building High risk Big factories Mid Risk Garage/Concession Small factory

16 External perimeter protection Active Infra Red Motion sensors
Modular AIR beams

17 SB250 / SB2100 2 beams Range: SB250 125m indoor 50m outdoor
4 channel selection Thermostaic contrlled heater on board Protection hight: 20cm Tx Ch 1 Rx Ch 1 Tx Ch 2 Rx Ch 2 Tx Ch 3 Rx Ch 3 Tx Ch 4 Rx Ch 4

18 SB450 / SB4200 4 beams Range: SB250 125m indoor 50m outdoor
4 channel selection Thermostaic contrlled heater on board Protection hight 40cm Tx Ch 1 Rx Ch 1 Tx Ch 2 Rx Ch 2 Tx Ch 3 Rx Ch 3 Tx Ch 4 Rx Ch 4

19 External perimeter protection Active Infra Red Motion sensors
Mounted in Pillars

20 Mounted in pillars To increase the protection hight, SB beams can be mounted in a mouting pillars. Available in : 1m, 1.5m, 2m, 2.5m, 3m

21 Back to back moting Both sides of the pillars can be used for the back to back mounting

22 1 – Beginning: The audience challenge
3 1 – Beginning: The audience challenge Installation

23 Beam alignement Horizontal alignment Vertical alignement

24 Power supply cable selction
Cable lengthe for power supply of 12V DC Cable lengthe for the heater of 12V DC/AC In case the mentioned cable lengthe/diameter limits your installation, use the optional 230VAC power supply (SB52)

25 Installation guideline
The protected area should not cut any beams

26 Installation guideline
Max 10° as accepted for the correct functionality Maximum 10°

27 Installation guidelines
Fence is the best physical perimeter protection which keep the large animals away

28 Installation guidelines
No vegeation my be between the Tx and Rx

29 1 – Beginning: The audience challenge
4 Application 1 – Beginning: The audience challenge

30 Military base VIP Estates / Residences Airports Communication Centre Correctional Institution Commercial Industrial


Download ppt "External perimeter protection Active Infra Red Motion sensors"

Similar presentations