Presentation is loading. Please wait.

Presentation is loading. Please wait.

3. System Components and Design Considerations

Similar presentations


Presentation on theme: "3. System Components and Design Considerations"— Presentation transcript:

1 3. System Components and Design Considerations

2 RWH System Components - the surface upon which the rain falls
 Catchment Area/Roof - the surface upon which the rain falls  Gutters and Downpipes - the transport channels from catchment surface to storage  Leaf Screens and Roofwashers - the systems that remove contaminants and debris  Cisterns or Storage Tanks - where collected rainwater is stored  Conveying - the delivery system for the treated rainwater, either by gravity or pump  Water Treatment - filters and equipment, and additives to settle, filter, and disinfect

3 Design considerations for rooftop catchment systems (1)
 The material of the catchment surfaces must be non-toxic and not contain substances which impair water quality.  Roof surfaces should be smooth, hard and dense since they are easy to clean and are less likely to be damaged and shed materials into water  Precautions are required to prevent the entry of contaminants into the storage tanks. - No overhanging tree should be left near the roof - The nesting of the birds on the roof should be prevented - A first flush bypass such as detachable downpipe should be installed

4 Design considerations for rooftop catchment systems (2)
 All gutter ends should be fitted with a wire mesh screen to keep out leaves, etc.  The storage tank should have a tight-fitting roof that excludes light, a manhole cover and a flushing pipe at the base of the tank.  The design of the tank should allow for thorough scrubbing of the inner walls and floor or tank bottom. A sloped bottom and a provision of a sump and a drain are useful for collection and discharge of settled grit and sediment.  Taps/faucets should be installed at 10 cm above the base of the tank as this allows any derbis entering the tank to settle on the bottom where it remains undisturbed, will not affect the quality of water.

5 Factors affecting RWH system design
 Rainfall quantity (mm/year)  Rainfall pattern  Collection surface area (m2)  Runoff coefficient of collection (-)  Storage capacity (m3)  Daily consumption rate (litres/capita /day)  Number of users  Cost  Alternative water sources

6 Feasibility of Rainwater Harvesting
 The technical feasibility of roof RWH as a primary source of water is determined by the potential of a rainwater to meet the demand more effectively than other alternatives.  Often the attraction of RWH may be as a supplementary water source to reduce the pressure on a finite primary source or as a backup during the time of drought or breakdown.  The total amount of water that is received in the form of rainfall over an area is called the rainwater endowment of that area.  The collection efficiency accounts for the fact that all the rainwater falling over an area cannot be effectively harvested.

7 Feasibility of Rainwater Harvesting
 The size of supply of rainwater depends on the amount of rainfall (R), the area of the catchment (A) and its runoff coefficient (C).  An estimate of mean annual runoff from a given catchment can be obtained using the equation: S = R * A * C Where S = Rainwater supply per annum R = mean annual rainfall A = Area of the catchment C = Runoff coefficient  The actual amount of rainwater supplied will ultimately depend on the volume of the storage tank or reservoir.

8 Catchment Area Size  The size of roof catchment is the projected area of the roof or the building’s footprint under the roof.  To calculate the catchment area (A), multiply the length (L) and width (B) of the guttered area. It is not necessary to measure the sloping edge of the roof.  Note that it does not matter whether the roof is flat or peaked. It is the “footprint” of the roof drip line that matters.

9

10 Source: http://www.eng.warwick.ac.uk/dtu/rwh/components2.html
Characteristics of Roof Types Type Runoff coefficient Notes GI sheets > 0.9 Excellent quality water. Surface is smooth and high temperatures help to sterilise bacteria Tile (glazed) 0.6 – 0.9 Good quality water from glazed tiles Unglazed can harbour mould Contamination can exist in tile joins Asbestos Sheets 0.8 – 0.9 New sheets give good quality water Slightly porous so reduced runoff coefficient and older roofs harbour moulds and even moss Organic (Thatch) 0.2 Poor quality water (>200 FC/100ml) Little first flush effect; High turbidity due to dissolved organic material which does not settle Source:

11 Example 1: For a building with a flat roof of size 10 m x 12 m in a city with the average annual rainfall of 800 mm Roof Area (A) = 10 x 12 = 120 m2 Average annual rainfall (R) = 800 mm = 0.80 m Total annual volume of rainfall over the roof = A * R = 120 m2 x 0.80 m = 96 m3 = 96,000 litres If 70% of the total rainfall is effectively harvested, Volume of water harvested = 96,000 x 0.7 = 67,200 litres Average water availability = 67,200 / 365 ~ 184 litres/ day

12 Storage System  There are several options available for the storage of rainwater. A variety of materials and different shapes of the vessels have been used.  In general, there can be two basic types of storage system: - Underground tank or storage vessel - Ground tank or storage vessel  The choice of the system will depend on several technical and economic considerations like, space availability, materials and skill available, costs of buying a new tank or construction on site, ground conditions, local traditions for water storage etc.

13 Storage System  The storage tank is the most expensive part of any RWH system and the most appropriate capacity for any given locality is affected by its cost and amount of water it is able to supply.  In general, larger tanks are required in area with marked wet and dry seasons, while relatively small tanks may suffice in areas where rainfall is relatively evenly spread throughout the year.  Field experiences show that a universal ideal tank design does not exist. Local materials, skills and costs, personal preference and other external factors may favour one design over another.

14 Requirements for Storage System
 A solid secure cover to keep out insects, dirt and sunshine  A coarse inlet filter to catch leaves etc.  A overflow pipe  A manhole, sump and drain for cleaning  An extraction system that does not contaminate the water e.g. tap/pump  A soakaway to prevent split water forming puddles near the tank.  Additionally features - sediment trap or other foul flush mechanism - device to inside water level in the tank

15

16

17

18 Source: Rees and Whitehead (2000), DTU, University of Warwick, UK
RWH Brick Jars - Uganda Source: Rees and Whitehead (2000), DTU, University of Warwick, UK

19 Source: John Gould (Waterlines, January 2000)
Rainwater Harvesting - Kenya Source: John Gould (Waterlines, January 2000)

20 Source: DTU, University of Warwick (September 2000)
Ferro-cement jar for rainwater collection - Uganda Source: DTU, University of Warwick (September 2000)

21 Underground lime and bricks cistern

22 Rainwater Harvesting – Sri Lanka

23

24

25

26 A wooden water tank in Hawaii, USA
                                              Source: Rainwater Harvesting And Utilisation. An Environmentally Sound Approach for Sustainable Urban Water Management: An Introductory Guide for Decision-Makers. ITEC, UNEP, Japan

27

28

29 Source: http://www.greenhouse.gov.au
Rainwater Tanks Source:

30 Storage capacity  When using rainwater, it is important to recognize that the rainfall is not constant through out the year; therefore, planning the storage system with an adequate capacity is required for constant use of rainwater, even during the dry period.  Knowledge of the rainfall quantity and seasonality, the area of the catchment surface and volume of the storage tank, and quantity and period of use required for water supply purposes is critical.  There are two commonly used method to estimate storage requirements.

31 Storage capacity Method 1 – Storage required for dry period
 A rough estimate of the maximum storage requirement can be made based on the (i) per capita consumption (ii) no of users and (iii) length of the longest dry period  For a household with a 5 people, assuming water use of 20 lpcd and if longest dry period is 30 days and rainwater is the only water source, storage required = 5 x 20 x 30 = 3000 litres

32 Storage capacity Method 1 – Storage required for dry period
 This simple method assumes sufficient rainfall and catchment area which is adequate, and is therefore only applicable in areas where this is the situation.  It is a method for acquiring rough estimates of tank size.

33 Storage capacity Method 2 – Based on rainfall and water demand pattern
 A better estimate of storage requirement can be made using the mass curve technique based on rainfall and water demand pattern.  Cumulative rainfall runoff and cumulative water demand in year is calculated and plotted on the same curve.  The sum of the maximum differences, on the either side, between the rainfall curve and water demand curve gives the size of the storage required

34 Storage capacity Example 2:
Calculate the size of the storage tank required for a school with 65 students and 5 staff, assuming average water consumption of 5 litres/day. Roof area = 200 m2. Assume runoff coefficient of 0.9. The rainfall pattern in the area is given in the table below Average daily demand = 70 x 5 = 350 litres Yearly demand = 350 * 365 = litres = m3 Average monthly demand = /12 ~ m3

35 Storage capacity calculations
(a) Rainfall pattern - 1

36 Required storage capacity = 29.4 m3 say 30 m3
Calculation of required storage capacity (1) Required storage capacity = 29.4 m3 say 30 m3

37 Mass curve for calculation of required storage capacity

38 Mass curve for calculation of required storage capacity

39 Storage capacity calculations
(b) Rainfall pattern - 2

40 Required storage capacity = 35.7 + 18.3 = 54 m3
Calculation of required storage capacity (2) Required storage capacity = = 54 m3

41 Gutters  Gutters are channels all around the edge of a sloping roof to collect and transport rainwater to the storage tank.  A carefully designed and constructed gutter system is essential for any roof catchment system to operate effectively.  When the gutters are too small considerable quantities of runoff may be lost due to overflow during storms.  The size of the gutter should be according to the flow during the highest intensity rain. It is advisable to make them 10 to 15 per cent oversize.

42 Gutters (2)  A general rule of thumb is that 1 cm2 of guttering is required for every m2 of roof area.  Gutters can be semi-circular or rectangular and could be made using a variety of materials: - Locally available material such as plain galvanised iron sheet (20 to 22 gauge), folded to required shapes. - Semi-circular gutters of PVC material can be readily prepared by cutting those pipes into two equal semi-circular channels. - Bamboo or betel trunks cut vertically in half. - Wood or plastic

43 Gutters (3)  Gutters need to be supported so they do not sag or fall off when loaded with water.  The way in which gutters are fixed depends on the construction of the house; - it is possible to fix iron or timber brackets into the walls, but for houses having wider eaves, some method of attachment to the rafters is necessary.  A properly fitted and maintained gutter-downpipe system is capable of diverting more than 80% of all runoff into the storage tank, the remainder being lost through evaporation, leakage, rain splash and overflow.

44 Gutters - Shapes and Configurations Gutter configurations

45 Gutters - Shapes and Configurations

46 Gutters and Hangers

47 Source: Peter Morgan (1998)
Shade cloth guttering Source: Peter Morgan (1998)

48 Plastic sheet guttering
                                       

49

50 Gutter sizing Recommended gutter widths for use in humid tropics
Gutter width (mm) Roof area (m2) served by 1 gutter 55 13 60 17 65 21 70 25 75 29 80 34 85 40 90 46 95 54 100 66 Source: (Still and Thomas, 2002)

51 Gutter sizing Optimum roof area drainable by square gutters (considering only conveyance) Square gutters Slope (%) 0.5 1 2 4 Gutter width Optimum roof area served by gutter (m2) 33 mm 10 14 20 28 50 mm 29 42 60 85 75 mm 88 125 177 250 100 mm 190 269 380 538 Source: (Still and Thomas, 2002)

52 Source: http://www.eng.warwick.ac.uk/DTU/rwh
Guttering for a 60 m2 roof Square 0.5% slope 1% slope Half round 1.0% slope 45o Triangle 1.0% slope Material use (mm) 214 189 150 175 Gutter width at top (mm) 71 63 96 124 Cross sectional area (cm2) 47 39 36 38 Source:

53 Roof area (m2) served by one gutter
Guide to sizing of gutters and downpipes for rainwater harvesting systems in tropical regions Source: Roof area (m2) served by one gutter Gutter width (mm) Minimum diameter of downpipe (mm) 17 60 40 25 70 50 34 80 46 90 63 66 100 128 125 75 208 150

54 First flush system (1)  Debris, dirt, dust and droppings will collect on the roof of a building or other collection area.  When the first rains arrive, this unwanted matter will be washed into the tank. This will cause contamination of the water and the quality will be deteriorated.  Many RWH systems therefore incorporate a system for diverting this ‘first flush’ or ‘foul flush” water so that it does not enter the storage tank.  Several first flush system are in use. The simplest one is a manually operated arrangement whereby the inlet pipe is moved away from the tank inlet and then replaced again once the initial first flush has been diverted.

55 First flush system (2)  For an average roof catchment it is suggested that the first 20–25 L could be diverted or discarded.  First flush devices should be regarded as an additional barrier to reduce contamination and should not be used to replace normal maintenance activities designed to keep roof catchments reasonably clean.  The inlet pipe to all rainwater tanks should be easily detachable so that, when necessary, the tank can be bypassed. Manual detachment could be used as an alternative to an engineered first flush device, although the level of control will not be as good.

56 Developed by Khon Kaen University, Thailand
First flush system (3) Developed by Khon Kaen University, Thailand

57 First flush system (4)

58 First flush system (5)

59 First flush system (6)

60 Device for separating rainwater from roof-accumulated impurities

61 Roof catchment system with filter and storage tank

62 Storage tank & first flush - Malaysia


Download ppt "3. System Components and Design Considerations"

Similar presentations


Ads by Google