Presentation is loading. Please wait.

Presentation is loading. Please wait.

Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T.

Similar presentations


Presentation on theme: "Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T."— Presentation transcript:

1 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T h e s i s 2 0 0 4 Andrea Hauber Architectural Engineering Lighting/Electrical Thesis Dr. Martin Luther King Jr. Library (San José Joint Library) San José, California Presentation: April 13, 2004 Consultant: Prof. Mistrick

2 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T h e s i s 2 0 0 4 Lighting Exterior Lobby Youth Reading Area Reading Area Electrical Design Requirements/Evaluation Re-switching Structural Exterior Lighting Connection Detail Mechanical Design Requirements/Evaluation

3 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T h e s i s 2 0 0 4 Lighting Exterior Lobby Youth Reading Area Reading Area Electrical Design Requirements/Evaluation Re-switching Structural Exterior Lighting Connection Detail Mechanical Design Requirements/Evaluation

4 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation A Joint Venture The Library is a Joint Venture between the City of San José and San José State University. The purpose is to bring together the students and public in order to promote a growing sense of community in the area.

5 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Location in San José, CA Conveniently located on the corner of the San José State University Campus to be open to the City of San José residence.

6 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Design City Entrance Campus Entrance $177.5 million 475,000 sq. ft. Library Eight floors plus a mezzanine and a lower level Construction 2000 - 2003

7 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Design Team Construction Manager: GILBANE BUILDING COMPANY General Contractor: HENSEL PHELPS Design Architect: CARRIER JOHNSON GUNNAR BIRKERTS ARCHITECTS Local Assoc. Architect: ANDERSON BRULE ARCHITECTS Structural: FORELL / ELSESSER, INC. MEP: FLACK + KURTZ CONSULTING ENGINEERS, LLP Lighting Design: FRANCIS KRAHE & ASSOCIATES, INC.

8 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Exterior Entrance Circulation Space Youth Area Evaluated Lighting Spaces Ground Floor

9 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area Evaluated Lighting Spaces

10 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Exterior Entrance Exterior Entrance from City Ground Floor

11 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Exterior Entrance from City Design Requirements IES: IES: Active Exterior Entrance: Very Important: Horizontal: 50 lux Vertical: 30 lux Appearance of Space and Luminaires, Light Pollution, Surface Characteristics, Color appearance and contrast, Direct Glare, Modeling of Faces or Objects, Peripheral Detection, Points of Interest, Reflected Glare, Shadows, Source/Task/Eye Geometry Important: Sparkle/Desirable Reflected Highlights, Light Distribution on Surfaces

12 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Exterior Entrance from City Schematic Design Initial design used the colors and symbols of the city and university to bring together the exterior of the building the way the library is to bring together the community.

13 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Exterior Entrance from City Final Design Final design places emphasis on the geometric aspect of the architecture of the building.

14 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Exterior Entrance from City Final Design Lower block: Four Tubular Series 4” Lower block: Four Tubular Series 4”@32’-8” Upper tubes: Upper tubes: Three Tubular Series 6” @ 60’

15 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Structural Detail

16 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Structural Connection

17 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area

18 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area Design Requirements IES: IES: Study Desks: Very Important: Horizontal: 300 lux Direct glare, Reflected glare, Source/task/eye geometry California Title 24: California Title 24: Library reading: 1.2 W/sq.ft.

19 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area Schematic Design

20 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area Final Design (13) Linear Fixtures (13) Linear Fixtures with one 32 watt T-8 lamp (1) Linear Fixture (1) Linear Fixture with two 32 watt T-8 lamps Allowed: Allowed: 34ft x 57ft x ½ = 970 sqft total Stack area = 192 sqft Reading Area = 778 sqft x 1.2 W/sqft = 933 W x 1.2 W/sqft = 933 W Actual: Actual: 15 lamps x 32 W =420 W 480 W / 778 sqft = 0.62 W/sqft

21 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area Final Design

22 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Reading Area Final Design

23 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Area Youth Reading Area Ground Floor

24 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Design Requirements IES IES Study Desks Very Important: Horizontal: 300 lux Direct glare, Reflected glare, Source/task/eye geometry California Title 24: California Title 24: Library reading: 1.2 W/sq.ft.

25 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Schematic Design The schematic design for a whimsical children’s reading area did not allow sufficient illumination for reading within the space.

26 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Final Design I (10) Pendant Indirect (10) Pendant Indirect with (2) 24 watt T-5HO mini bi-pin base and (3) 50 watt low-voltage halogen Allowed: Allowed: Reading Area = 1780 sqft x 1.2 W/sqft = 2136 W Actual: Actual: 10 fixtures x 198 W = 1980 W 1980W / 1780 sqft = 1.11 W/sqft

27 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Final Design I

28 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Final Design I

29 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Final Design II (10) Pendant Downlight (10) Pendant Downlight Lamp 50 watt low-voltage halogen (19) Downlight (19) Downlight Lamp 50 watt low-voltage halogen Lamp 50 watt low-voltage halogen Allowed: Allowed: Reading Area = 1780 sqft x 1.2 W/sqft = 2136 W Actual: Actual: 29 lamps x 50 W = 1450 W 1450W / 1780 sqft = 0.82 W/sqft

30 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Final Design II

31 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Youth Reading Area Final Design II

32 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Ground Floor

33 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Design Requirements IES: IES: Library Circulation Desk Very Important: Horizontal: 300 lux Reflected Glare, Source/Task/Eye Geometry Important: Appearance of space and luminaires, Direct Glare, Light Distribution on Surfaces and Task Plane (uniform), Color appearance and contrast, Modeling of Faces or Objects Lobby General Somewhat Important: Horizontal: 100 lux Important: Appearance of space and luminaires Day lighting integration and control, Color appearance and color contrast, Direct glare, Light distribution on surfaces, Luminance of room surfaces, Modeling of faces or objects, and Points of interest California Title 24: Lobby: 1.5W/sqft. Corridor: 0.6W/sqft California Title 24: Lobby: 1.5W/sqft. Corridor: 0.6W/sqft

34 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Schematic Design

35 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Final Design (16) Indirect/Direct Single Uplight fixtures (16) Indirect/Direct Single Uplight fixtures with six 25 watt T-8 lamps (4) Indirect/Direct Quad (4) Indirect/Direct Quad with four luminaires at six 25 watt T-8 lamps each (12) Chieftan Sconce (12) Chieftan Sconce with two 21 watt T-5 lamps

36 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Final Design Allowed: Allowed: 8790 sqft total 1.2 W/sqft as lobby= 10548 W 0.6 W/sqft as corridor= 5274 W Actual: Actual: 32fixtures x 6lamps x 25W = 4800 12fixtures x 2lamps x 21W = 504 Total = 5304 Watts = 0.601 W/sqft

37 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Final Design The architecture of the building allows for much day light to come through angular light shafts and windows. This fixture will bring that architectural detail into the ground floor lobby space.

38 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Final Design

39 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Circulation Space Final Design Higher illuminance levels have been used at the entrances. The general illuminance is around 300 lux to allow the lobby to be used for multiple purposes.

40 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation Thank You! Questions?Comments?

41 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Stack Controls Three way Timer Switch LevelStack rowSwitchesLamps GS12022 Youth234558 2N3978151 2S295876 3N82164353 3S71142238 450 100 54780135 6N62124200 6S85168299 7N62124200 7S95187334 8N62124200 8S95187334 Total81415312700 Watts2700 lamps * 35 W=94500 W

42 Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Final Presentation Stack Controls Three way Timer Switch


Download ppt "Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T."

Similar presentations


Ads by Google