Download presentation
Presentation is loading. Please wait.
Published bySibyl McCoy Modified over 9 years ago
1
Product Presentation 2007 SUPER INVERTER
2
2 21-Sep-15 Public SKY AIR & PACKAGED SUPER INVERTER
3
3 21-Sep-15 Public 1.Model range 2.Product features - Easy Installation - Flexible Design - Energy Saving 3. Specifications Overview
4
4 21-Sep-15 Public MARKET High end Mainstream Low end Inverter High ‘RZQ- series’ Heat pump Non Inverter Non-Inverter H/P ‘REQ-series’ Non-Inverter H/P ‘RQ-series’ Non-Inverter C/O ‘RR-series’ Inverter Low ‘RZQS-series’ RZQ200BW (3ph) RZQ250BW (3ph) RZQ71CV1 RZQ100CV1 (1ph) RZQ125CV1 RZQ140CV1 RZQ100BW1 RZQ125BW1 (3ph) RZQ140BW1 1. Model range Sky Air Packaged
5
5 21-Sep-15 Public Wide range of indoors: 8 different models in 33 different variants 1. Model Range
6
6 21-Sep-15 Public MODEL NAME Ceiling suspended2 x 2 cassette4-way ceilingWall mounted High ESP duct FHQFFQFUQFAQFDQ 355060711001253550607110012571100125 RZQ71CV1 2P2PP RZQ100CV1 32P32PP RZQ125CV1 432P432PP RZQ140CV1 4324322 MODEL NAME Round flow High COPRound flow cassetteDuct (medium ESP) FCQHFCQFBQ 711001251403550607110012514035506071100125140 RZQ71CV1 P2P2P RZQ100CV1 P32P32P RZQ125CV1 P432P432P RZQ140CV1 2P432P432P Combination Table RZQ71/100/125/140C 1. Model Range
7
7 21-Sep-15 Public Wide range of indoors: 8 different models in 30 different variants 1. Model Range
8
8 21-Sep-15 Public MODEL NAME 4-way-blow cassetteRound flow cassetteDuct (medium ESP) FCQ-BFCQ-CFBQ 355060711001253550607110012535506071100125 RZQ200C433243324332 RZQ250C424242 MODEL NAME Ceiling suspended2 x 2 cassette4-way ceilingWall mountedHigh ESP duct FHQFFQFUQFAQFDQ 355060711001253550607110012571100125200250 RZQ200C4332433232P RZQ250C42422P 200 class250 class P: Pair combination 200250 2: Twin 100 + 100125 + 125 3: Triple 60 + 60 + 60 / 71 + 71 + 71- 4: Double twin 50 + 50 + 50 + 5060 + 60 + 60 + 60 Combination Table RZQ200/250C 1. Model Range
9
9 21-Sep-15 Public Easy Installation Easy piping: => max. piping length 75m => piping length below 5m => re-use of field piping => flexible piping diameter Compact design: => same casing 4/5/6 HP Anti-corrosion treatment Light weight: => 98kg for 4/5/6 HP Flexible Design Flexible operation range: => C/O operation possible => down to -20°C in heating => up to +50°C in cooling EDP room application: => R/C field setting => I/U operation limit 11°C Wide range of indoors: => 8 different models => 33 different variants D-Bacs compatibility Energy Saving Increased efficiency: => top COP => DC inverter technology => I-demand Predicted mean value Environmentally friendly Reduction of initial charge refrigerant Corresponding to F-gas regulation RoHS-complaint 2. Product Features
10
10 21-Sep-15 Public Easy Installation Piping length: Maximum piping length = 75m Minimum piping length = 5m minimum allowed piping length is 3m (by field setting) Flexible piping diameter suitability of Sky Air models to existing pipes (of other brands) H = 30m Model Liquid PipingGas Piping Size DownStandardSize UpSize DownStandardSize Up RZQ71CV1Ø 6.4Ø 9.5Ø 12.7 Ø 15.9-- RZQ100CV1Ø 6.4Ø 9.5Ø 12.7--Ø 15.9Ø 19.1 RZQ125CV1Ø 6.4Ø 9.5Ø 12.7--Ø 15.9Ø 19.1 RZQ140CV1Ø 6.4Ø 9.5Ø 12.7--Ø 15.9Ø 19.1 Re-use of field piping 2. Product Features
11
11 21-Sep-15 Public Compact design: Dimensions same casing for 100, 125 & 140 class models reduced height for 100 & 125 class (-175mm) => 1.170mm * 900mm * 320mm (H*W*D) HeightWidthDepth RZQ100B8V31.345900320 RZQ100CV11.170900320 RZQ125B8V31.345900320 RZQ125CV11.170900320 RZQ140CV11.170900320 Light weight: Same weight for 100, 125 & 140 class models Reduced weight for 100 & 125 class => 98kg New RZQ 100/125/140 RZQ 100/125 98k g 106k g 2. Product Features Easy Installation
12
12 21-Sep-15 Public Easy Installation Easy piping: => max. piping length 75m => piping length below 5m => re-use of field piping => flexible piping diameter Compact design: => same casing 4/5/6 HP Anti-corrosion treatment Light weight: => 98kg for 4/5/6 HP Flexible Design Flexible operation range: => C/O operation possible => down to -20°C in heating => up to +50°C in cooling EDP room application: => R/C field setting => I/U operation limit 11°C Wide range of indoors: => 8 different models => 33 different variants D-Bacs compatibility Energy Saving Increased efficiency: => top COP => DC inverter technology => I-demand Predicted mean value Environmentally friendly Reduction of initial charge refrigerant Corresponding to F-gas regulation RoHS-complaint 2. Product Features
13
13 21-Sep-15 Public Flexible Design Wide operation range: In cooling: -15°C / 50°C (vs. -5°C / 46°C for RZQS-series) In heating: -20°C / 15.5°C (vs. -15°C / 15.5°C for RZQS-series) C/O operation possible (setting to disable heating mode) 2. Product Features
14
14 21-Sep-15 Public EDP room application: MODEL NAME Round flow High COPRound flow cassetteDuct (medium ESP) FCQHFCQFBQ 711001251403550607110012514035506071100125 RZQ71CV1 P32P32P RZQ100CV1 2P432P432 RZQ125CV1 2P432P432 RZQ140CV1 MODEL NAME Ceiling suspended2 x 2 cassette4-way ceilingWall mounted High ESP duct FHQFFQFUQFAQFDQ 355060711001253550607110012571100125 RZQ71CV1 32P32PP RZQ100CV1 4324322 RZQ125CV1 4324322 RZQ140CV1 2. Product Features Flexible Design
15
15 21-Sep-15 Public EDP room application: EDP application is incorporated by field setting with R/C Extended operation range till 11°CWB (indoor) in cooling mode Minimum allowed piping length should be 3m D-Bacs compatibility: Compatibility with Intelligent Manager Compatibility with Intelligent Touch Controller IndoorOutdoor 4 HP3 HP 6 HP4 HP 6 HP5 HP Basic logic for EDP room 2. Product Features Flexible Design
16
16 21-Sep-15 Public Easy Installation Easy piping: => max. piping length 75m => piping length below 5m => re-use of field piping => flexible piping diameter Compact design: => same casing 4/5/6 HP Anti-corrosion treatment Light weight: => 98kg for 4/5/6 HP Flexible Design Flexible operation range: => C/O operation possible => down to -20°C in heating => up to +50°C in cooling EDP room application: => R/C field setting => I/U operation limit 11°C Wide range of indoors: => 8 different models => 33 different variants D-Bacs compatibility Energy Saving Increased efficiency: => reduced start-up time => DC inverter technology => I-demand Predicted mean value Environmentally friendly Reduction of initial charge refrigerant Corresponding to F-gas regulation RoHS-complaint 2. Product Features
17
17 21-Sep-15 Public Energy Saving Less frequent start/stop cycles Automatic throttle back of capacity Start-up time down by 1/3 Operating at partial load possible Varying speed of compressor Inverter technology: => Energy efficiency significantly higher Sine Wave DC inverter: Increase of efficiency High harmonics reduced => 98% electricity used 2. Product Features
18
18 21-Sep-15 Public Swing Compressor Swing bush Ref. Gas The piston which the blade and the roller unified Discharge Suction Scroll Reluctance DC Motor Low Pressure Part High Pressure Part Low starting current More stable set points Class 71 Friction & leaks suppressed Improved energy saving Scroll Compressor Scroll Compressor Reluctance DC compressor: Class 100, 125 & 140 Easier superheat control Improved performance 2. Product Features Energy Saving
19
19 21-Sep-15 Public 4 Neodymium magnets: More powerful than ferrite types Better performance Higher energy efficiency Energy cost savings ↑ DC Fan motor: Improvements in operating efficiency (especially during low speed) Improvement in energy efficiency (at low velocities in particular) Neodymium magnets Increased torque for same consumption Optimized version of DC motorAdditional torque / same energy consumption FEATURESBENEFITS 2. Product Features Energy Saving
20
20 21-Sep-15 Public I-demand function: Operation: difference actual/predefined power consumption minimized Max. power consumption limited to 80%~40% of rated power input KRP58M51 (optional adaptor) required Power Consumption (kW) Time Maximum power consumption can be easily controlled: The maximum capacity is maintained while the power consumption is kept at a certain level. The set value can be freely changed. When the function is turn on, Demand 1 starts as default setting (Setting on the optional PCB) External Input Demand 1 ~ 3 External Control Adaptor (Optional PCB) SettingPower Consumption Demand 1 Select from 80%-70%-60 % Demand 2 40 % Demand 3 0 % Contact Changeover Setting way 2. Product Features Energy Saving
21
21 21-Sep-15 Public Predicted Mean Value: [Day] Muggy [Night] Chilly [Morning] Chilly Always comfortable Cost-efficient operation Cooling Shortage of capabilityOver capability Unnecessary cooling High Room Temperature Low Set point 23°C Energy saving Auto Operation Mode: Controls room temperature in accordance with feeling temperature. Normal Operation Mode: Controls room temperature at a designated temperature. [Day] Muggy [Night] Chilly [Morning] Chilly Always comfortable Cost-efficient operation 2. Product Features Energy Saving
22
22 21-Sep-15 Public Predicted Mean Value: Heating [Morning] Cold [Night] Cold [Day] Hot Always comfortable Cost-efficient operation High Room Temperature Over capability Unnecessary heating Low Shortage of capability Shortage of capability Set point 21°C Energy saving 2. Product Features Energy Saving Auto Operation Mode: Controls room temperature in accordance with feeling temperature. Normal Operation Mode: Controls room temperature at a designated temperature.
23
23 21-Sep-15 Public RZQ200/250C Energy saving => high efficiency => power limit setting Easy piping: => max. piping length 100m => re-use of field piping => flexible piping diameter Light weight: => 198kg for 8 & 10 HP Possibility of C/O operation Night quiet operation Remarks No change in option list Not suited: => for EDP room applications => for piping length < 5m 2. Product Features
24
24 21-Sep-15 Public Super Inverter Model nameRZQ71CV1RZQ100CV1RZQ125CV1RZQ140CV1 4-way Casette TypeHi Casette / Thin Casette Rated cooling capacity7.1kW10.0kW12.5kW14.0kW Rated cooling COP (Hi/Thin Cassette) 3.59 / 3.36 (A) / (A) 3.76 / 3.61 (A) / (A) 3.38 / 3.22 (A) / (A) 3.02 / 2.61 (B) / (D) Max cooling capacity8.0kW11.2kW14.0kW15.4kW Rated heating capacity8.0kW11.2kW14.0kW16.0kW Rated heating COP (Hi/Thin Cassette) 4.06 / 3.62 (A) / (A) 4.39 / 3.71 (A) / (A) 3.92 / 3.54 (A) / (B) 3.61 / 3.21 (A) / (C) Max heating capacity9.0kW12.8kW16.2kW18.0kW Operation sounds(Cool/Heat)47/49 dB(A)49/51dB(A)50/52 dB(A) Sound Power Cooling63 dB(A)65 dB(A)66 dB(A)67 dB(A) Dimensions H770×W900 ×D320mm H1170×W900×D320mm Weight68kg98kg Refrigerant Quantity2.8kg3.7kg CommunicationQA Communication Ref.pipe size Gasφ15.9 Liquidφ9.5 Ref.pipe length MAX ref.pip length50m75m MIN ref.pip length5m Charged for30m 3. Specifications
25
25 21-Sep-15 Public RZQ200CRZQ250C FDQ200BV3FDQ250BV3 Cooling Rated CapacitykW2024,1 EER 3.21 (A)2,81 (C) Min. - Max. CapacitykW7,5 - 22,49,1 - 26,5 Heating Rated CapacitykW2326,4 COP 3.41 (B)3,21 (C) Min. - Max. CapacitykW8,5 - 259,1 - 29,0 Dimensions Heightmm1680 Widthmm930 Depthmm765 Weight kg198 Piping Connection Piping Length Minimumm55 Maximumm100 Chargelessm30 Diameter Liquidmm9,512,7 Gasmm22,2 Height Difference m30 Operation Range Cooling ℃ DB -5 / + 46 Heating ℃ WB -15 / +15 Sound Level Sound PressureCO/HPdBA57/5757/58 Sound Power (Cooling)dBA78 3. Specifications
26
26 21-Sep-15 Public
27
27 21-Sep-15 Public