Download presentation
Presentation is loading. Please wait.
Published byGriffin Rich Modified over 9 years ago
1
iFluka : a C++ interface between Fairroot and Fluka Motivations Design The CBM case: –Geometry implementation –Settings for radiation studies –Global diagnosis Conclusion and Outlook
2
Motivations Non intrusive interface Fluka used in analogue or biased mode C++ programming using Fairroot Class Library –Generators ( Urqmd, etc... ) –Field maps definition –Standardized IO using Fairroot file structure –Parameters containers
3
Design FairRoot
4
iFluka Features Fluka version 2006.3b C++ FairRoot interface to native Fluka –Enable usage of FairRoot class library directly precise field maps info (CbmFieldMap) external generators ( CbmUrqmdGenerator etc..) etc... –FairRoot IO supported All Root IO + Stack info: (CbmMCTrack) Detector scoring info stored using CbmMCPoint General Fluka mesh normalization routine –directly linked with Fluka executable –Fluences -> Dose –Fluence -> 1 MeV n-eq –etc..
5
Radiation study settings –Geometry: CBM cave ( based on technical drawings + modifs ) Magnet + (1% ) target + MUCH ( compact design ) taken from CbmRoot –Primary sources: DPMJET-III (delta rays + beam / beam dump ) UrQmd (Au-Au central collisions ) –Secondaries (transport): Delta –rays: 50 KeV, hadrons 100 KeV Low-energy neutrons library activated –Magnetic field map from CbmRoot –1 Mev n-equivalent fluence normalization
6
New Geometry of the CBM Cave
7
Scoring planes Much scoring planes MDV+STS Scoring planes
8
CBM Detectors (2)
9
CBM Cave Geometry ZY viewXZ view
10
NIEL (1) NIEL (1) Displacement damage on Si lattice proportional to non ionizing energy transfer (NIEL) ( n, p, π+/-,e). To characterize the damage efficiency of a particle at E –Use of the normalized damage function D(E)/D(1Mev) –Tables taken from A.Vasilescu and G. Lindstroem ( http://sesam.desy.de/menbers/gunnar/Si-func.htm)http://sesam.desy.de/menbers/gunnar/Si-func.htm Normalization of hadron fluence Φ : Φ (1 MeV n-eq) = ∫ (D(E)/D(1 MeV)) Φ(E) dE with D(1 MeV) = 95 MeV mb. Φ (1 MeV n-eq) : equivalent 1 MeV-n fluence producing the same bulk damage
11
NIEL (2) NIEL (2)
12
Cave charged particles fluence DPM UrQmd
13
Cave neutrons fluence DPM UrQmd
14
The electronics cave
15
Much : Energy density
16
Much: Charged particles fluence
17
Much: neutrons particles fluence
18
Conclusion iFluka ready to be used for radiation level studies On going work: –More detailed Geometry –run time conversion to ROOT format for all Fluka estimators –Normalization routine in C++ –Comparison with TFluka (Validation) ( Collaboration with ALICE )
19
CBM radiation environment Detectors –MVD + STS –MUCH Estimators: –Energy density ( GeV/cm3/primary ) –Fluence ( 1 Mev n equivalent : n-equiv/cm2/primary)
20
CBM detectors radiation level
21
Geometry
22
Scoring planes Much scoring planes MDV+STS Scoring planes
23
MVDs energy density
24
STS Energy density (1) Sts 1 Sts 2 Sts 3Sts 4
25
Sts energy density Sts energy density STS 5 STS 6 STS 7 STS 8
26
MUCH energy density MUCH 1 MUCH2 MUCH 3 MUCH 4
27
MUCH energy density MUCH 5MUCH 6
28
MVDs Charged particles fluence MVD 1MVD 2
29
STS charged particles fluence STS 1 STS 2 STS 3 STS 4
30
Sts charged particles fluence STS 5 STS 6 STS 7 STS 8
31
MUCH charged particles fluence MUCH 1 MUCH 2 MUCH 3 MUCH 4
32
Much charged particles fluence MUCH 5 MUCH 6
33
MVDs neutrons fluence MVD 1 MVD 2
34
Sts neutrons fluence STS 1 STS 2 STS 3 STS 4
35
Sts neutrons fluence STS 5 STS 6 STS 7STS 8
36
MUCH neutrons fluence MUCH 1MUCH 2 MUCH 3MUCH 4
37
MUCH neutrons fluence MUCH 5 MUCH 6
38
Conclusion iFluka used to estimate fluences for MVD, STS and MUCH Need to overlay results from UrQmd with DPM (beam dump) Need more input from detector groups Compare with real data ( TRD... ) and other MC ?