IMAGE QUALITY REVIEW RT
2
What affects DENSITY on the radiographic image?
3
Factors Affecting mAs & Density
Patient factors: size of pt., density / pathology of tissue kVp Collimation Distance Grids Film/Screen Combinations Processing
4
Factors Affecting mAs Patient factors: size of pt., density of tissue, pt. compliance kVp Distance Grids Film/Screen Combinations Processing
5
Influences technique & density on image
Patient’s Body Habitus (size) Influences technique & density on image
6
PATHOLOGY ?
7
pneumothorax Lung collapses No tissue in space
Easy to penetrate with x-ray photons pneumothorax
8
LUNG Cancer
9
DON’T ! WE WANT YOU HEALTHY & NOT SMELLY !
10
LUNG CANCER
11
Creating the Image Scatter Creates fog Lowers contrast (more grays)
Increases as kV increases Field size increases Thickness of part increases
12
Effects of collimation on scatter
13
Collimate to area of interest -reduces scatter and radiation dose to the patient
14
Grids A device with lead strips that is placed between the patient and the cassette Used on larger body parts to reduce the number of scattering photons from reaching the image
15
Grid is placed between patient (behind table or upright bucky) & cassette If placed BACWARDS CAN CAUSE GRID ERRORS
16
GRIDS CAN LEAVE LINES ON THE IMAGE
17
DETAIL & Quality : How well we can see something on the image
18
The degree of sharpness in an object’s borders and structural details.
How “clear” the object looks on the radiograph
19
Recorded Detail The degree of sharpness in an object’s borders and structural details. Other names: -sharpness of detail -definition -resolution -degree of noise
20
2 principal characteristics of any image are Spatial & Contrast Resolution
Spatial resolution Resolution is the ability to image two separate objects and visually distinguish one from the other Spatial resolution is the ability to image small objects that have high subject contrast (eg. bone-soft tissue interface, calcified lung nodules)
21
2 principal characteristics of any image are Spatial & Contrast Resolution
Spatial resolution Determined by focal-spot size and other factors that contribute to blur Diagnostic x-ray has excellent spatial resolution. It is measured in line pairs per mm. (CT measured in cm)
22
Factors that affect the detail of an image
23
Factors that affect Recorded Detail
Geometric unsharpness OID SID SIZE SHAPE Motion unsharpness (blurring) Intensifying Screens Film Speed / Compostion Film – Screen contact Kvp & Mas (density / visibility)
24
Main Factors Affecting Recorded Detail
kVp & mAs Motion Object Unsharpness Focal Spot Size SID (Source to Image Distance) OID (Object to Image Distance) Material Unsharpness
25
GEOMETRIC QUALITIES DETAIL DISTORTION MAGNIFICATION
27
RESOLUTION TEST TOOLS LINE PAIRS/ MM Depits how well you can see the differences in structures More lines=more detail
29
POOR DETAIL GOOD DETAIL
30
Motion Can be voluntary or involuntary
Best controlled by short exposure times Use of careful instructions to the pt. Suspension of pt. respiration Immobilization devices
31
Decrease Motion Unsharpness
Instruct patient not to move or breath Use Immobilization devices Use Short exposure times Lock equipment in place
32
Blurring of image due to patient movement during exposure.
36
Object Unsharpness Main problem is trying to image a 3-D object on a 2-D film. Human body is not straight edges and sharp angles. We must compensate for object unsharpness with factors we can control: focal spot size, SID & OID
37
SID Source to Image Distance
The greater the distance between the source of the x-ray (tube) and the image receptor (cassette), the greater the image sharpness. Standard distance = 40 in. most exams Exception = Chest radiography 72 in. *See page 74 in your book
38
The position of the tube (SID) to IR Will influence how the structures appear on the image The farther away – the less magnified ↑SID ↓ MAGNIFICATION
39
SID Shine a flashlight on a 3-D object, shadow borders will appear “fuzzy” -On a radiograph called Penumbra Penumbra (fuzziness) obscures true border – umbra Farther the flashlight from object = sharper borders. Same with radiography.
41
OID Object to Image Distance
The closer the object to the film, the sharper the detail. OID , penumbra , sharpness OID , penumbra , sharpness Structures located deep in the body, radiographer must know how to position to get the object closest to the film. *See page 74 in your book
42
The position of the structure in the body will influence how magnified it will be seen on the image
The farther away – the more magnified
43
Focal spot size – determined by filament in cathode & surface area used at anode
45
Distortion Misrepresentation of the true size or shape of an object
-MAGNIFICATION (size distortion) -TRUE DISTORTION (shape distortion)
46
MAGNIFICATION TUBE CLOSE TO THE PART (SID)
PART FAR FROM THE CASSETTE (OID)
49
In terms of recorded detail and magnification, the best image is produced with a small OID and a large SID.
54
40” SID VS 72” SID
55
MAGNIFICATION PROBLEMS
SID SOD SID – OID = SOD
56
Size Distortion & SID Major influences: SID & OID
As SID , magnification Standardized SID’s allow radiologist to assume certain amt. of magnification factors are present Must note deviations from standard SID
57
Size Distortion & OID If source is kept constant, OID will affect magnification As OID , magnification The farther the object is from the film, the more magnification
58
A = good B & C = shape distortion (elongation of part)
59
D & E = shape distortion (foreshortening of part)
60
Shape Distortion Misrepresentation of the shape of an object
Controlled by alignment of the beam, part (object), & image receptor Influences: Central ray angulation & body part rotation
61
Image Distortion When the part to be imaged – does not lay parallel with the IR (cassette) If the Central Ray is not perpendicular to the part
65
Elongation Foreshortened Normal
67
Distortion (x-ray beam not centered over object & film)
Distortion (object & film not parallel)
68
Central Ray Radiation beam diverges from the tube in a pyramid shape.
Photons in the center travel along a straight line – central ray Photons along the beam’s periphery travel at an angle When central ray in angled, image shape is distorted.
69
Distortion of multiple objects in same image (right) due to x-ray beam not being centered over objects.
70
Central Ray Angulation
Body parts are not always 90 degrees from one another Central ray angulation is used to demonstrate certain details that can be hidden by superimposed body parts. Body part rotation or obliquing the body can also help visualize superimposed anatomy.
71
Main Factors Affecting Recorded Detail
kVp & mAs Motion Object Unsharpness Focal Spot Size SID (Source to Image Distance) OID (Object to Image Distance) Material Unsharpness/ Film Screen Combo
72
Factors Affecting mAs Patient factors: size of pt., density of tissue, pt. compliance kVp Distance Grids Film/Screen Combinations Processing
73
Focal Spot Size Smaller x-ray beam width will produce a sharper image.
Fine detail = small focal spot (i.e. small bones) General radiography uses large focal spot Beam from penlight size flashlight vs. flood light beam *See page 73 in your book
74
ANODE ANODE
76
THE SMALLER THE BEAM TOWARDS THE PATIENT - THE BETTER THE DETAIL OF THE IMAGE PRODUCED
77
FOCAL SPOT ANGLE SMALLER ANGLE – SMALLER BEAM AT PATIENT
79
REVIEW Intensifying Screens and Film
80
“Fast” Screen Cassettes
Equipment used can contribute to image unsharpness Fast film/screen combinations = decrease in image sharpness Slower film/screen combinations = increase in image sharpness
81
Fast screen vs Slower screen
82
QUANTUM MOTTLE Not enough PHOTONS – can create a mottled or grainy image - MORE COMMON IN CR SYSTEMS
83
SAME TECHNIQUE CHANGE IN SCREEN SPEED
SLOWER FASTER
84
CASSETTES with Intensifying Screens
The CASSETTE holds the film in a light tight container It consist of front and back intensifying screens
85
Intensfying screens Lower patient dose (less photons needed)
Changes resolution of image Slow screens less LIGHT = better detail Faster – less detail (more blurring on edges)
89
Intensifying Screens:
Located inside the cassette (film holder) Contains Phosphors: Calcium Tungstate Blue to purple light Rare Earth Green & Ultraviolet light
90
CHANGING CR SPEED
91
F/S SPEED CHANGES
92
CR SPEED CLASS
93
WIDER LATITUDE & DYNAMIC RANGE WITH CR
96
POOR SCREEN CONTACT FOAM BACKING HELPS TO PLACE INTENSIFYING SCREENS IN DIRECT CONTACT WITH THE FILM – NO GAPS IF GAPS – MORE LIGHT CAN BE EMITTED IN SPACE, CAUSING THE IMAGE TO BE OF POOR DETAIL
97
Tight contact needed between film & screens
98
WIRE MESH SCREEN CONTACT TEST
99
When there is a space between the contact of the film to the intensifying screens, a larger amount of light is allowed to reach the film – causing “more density” on fim
100
Lack of contact between film and cassette can cause “blurring” of the image
101
LOADING FILM IN CASSETTE
102
IMAGE ON FILM SINGLE EMULSION = BETTER DETAIL
DOUBLE EMULISON = LESS DETAIL PARALLAX With double emulsion – an image is created on both emulsions – then superimposed – slight blurring of edges
103
PARALLAX – each emulsion has an image single image overlaped edges edge sharp less sharp
104
Film Characteristics (more in week 9)
Film contains silver halide crystals 2 layers – emulsion & base emulsion thickness determine speed of film and degree of resolution Speed – the response to photons Resolution – the detail seen
105
Film Speed / Crystal size
Larger crystals or Thicker crystal layer Faster response= less detail, and less exposure (chest x-ray) Finer crystals / thinner crystal layer =Slower response, greater detail, more exposure (extremity)
106
Processing Film (wk 10) Film contains silver crystals
If crystals exposed to photons – will convert to black after placed in processing chemicals If not exposed – will remain clear on film
107
Goal : Produce Optimal Images for diagnosis
108
Too dark too light Out of focus good image