1 Glenair AmberStrand ® Composite EMI/RFI Braid

2 AmberStrand ® Composite EMI/RFI Braid  Nickel Plated Composite Shielding Offers Unique Solution to Electromagnetic Compatibility  Expandable, flexible, high-strength, conductive, thermoplastic material  Provides abrasion resistance and EMI shielding at a fraction of the weight of metal braid

3 Glenair AmberStrand ® Features  Shields from 80db to 40db in 100Khz @ 1Ghz  Superb optical braid coverage - 90-95%  Full mechanical function - Crimp, Band-It, Solder  Extremely strong fiber coated with Nickel or Silver.  Meets limits of 1.0% max outgas test to IAW ASTM-595-90 and 0.10% max. CVCM  Meets Lightning strike ANSVEIA-364-75 specification at 3Kva, 6Kva & 10Kva wave form B  High flexure strength and flexibility -80˚C to +220˚C  Excellent Abrasion and Burn Resistance “The Weight Saver” - average 78% less than tin/copper

4 Glenair AmberStrand ® Market Applications  Reduce the Size and Weight of Interconnect Systems  Eliminate EMI Signal Distortion on interconnect assemblies  Solve High Cycle/High Flexure Mechanical Assembly issues  Perform in High Temperature Applications

5 AmberStrand ® Weight Savings  100 feet of ¼” AmberStrand vs. Tin/Copper shield saves 3+ Lbs.  100 feet of 5/8” AmberStrand vs. Tin/Copper shield saves 5+ Lbs.  Estimated system weight savings in a mix of AmberStrand sizes totaling 1000 feet in length could save 40 to 50 pounds or more.  In a Jumbo Jet longer lengths of AmberStrand could add up to passengers being “lost” via weight savings.

6 AmberStrand ® Weights and Carrier Breakdown

7 103-026 AmberStrand vs. Tinned Copper QQB SizeDia. AmberStrand LBS per cft 100-001 LBS per cft LBS Difference% Lighter 002.062.1322.40.267867.5% 004.125.22051.03.809578.6% 008.250.39683.453.05388.5% 012.375.50713.953.44387.1% 016.500.81574.773.95482.9% 020..625.97005.944.97083.6% 024.7501.1467.305.15484.4% 0321.0001.76377.505.73676.4% AmberStrand ® Weight vs. Tin/Copper

8 AmberStrand ® 100% Light Weight Metal Clad Composite Braid Nickel Plated 103-026 Tensile strength590,000 psi (min.)ISO 37 Ultimate elongation2.5% (min.)ISO 37 Operating Temperature-80°C to 220°C85% Shielding effectiveness 1000 hours Specific gravity1.45% (max.)ISO 1183 Thermal Cycling No adverse affects in visual inspection or resistance after 50 cycles -65°C to +200°C Lightning CurrentGlenair Qual. Test Report 040607AMBANSI/EIA-364-75-1977 Wave Form B Surface Transfer ImpedanceGlenair Qual. Test Report 040607AMBIEC 600096-1, Amendment 2 Vertical Flammability Self extinguishing ≤ 2 sec Burn length 0.1 in max - Dripping 0.0 seconds 14 CFR part 25.853 (a) AMdT25-116 Appendix F Part I (a) (1) (ii) Fungus Resistance Testing 28-day Incubation Test – Results - no fungus growth MIL-Std 810F, Method 508.5 Mass loss and Collected Volatile Condensable Materials 1.0% max. mass;.10% max CVCMASTM E-595

9 Flex Test 50,000 cyclesNo tearing or visible damage90° - 120° bend Salt Spray 500 Hrs DC Resistance IAW AS85049.5 millohm; No evidence of base metal on braid ASTM B117-03 Sodium Chloride 5% Salt Fog N/SO2No damage or adverse affectsASTM G 85 Annex 4 200 Hours JP-8 (Mil-T-83133) Military Jet Aircraft Fuel (70°C) No fraying, DC resistance within limits (AS85049 paragraph 4.6.3) Mil-Std 810F Method 504 (modified) Skydrol Military Jet Aircraft fuel (90˚C) No fraying, DC resistance within limits (AS85049 paragraph 4.6.3) Mil-Std 810F Method 504 (modified) Hydraulic Fluid Mil-H-5606 (70°C) No fraying, DC resistance within limits (AS85049 paragraph 4.6.3) Mil-Std 810F Method 504 (modified) Silicate Ester Base Coolanol 25R (70°C) No fraying, DC resistance within limits (AS85049 paragraph 4.6.3) Mil-Std 810F Method 504 (modified) Polyalphaolefin Mil-C-87252 (70°C) No fraying, DC resistance within limits (AS85049 paragraph 4.6.3) Mil-Std 810F Method 504 (modified) AmberStrand ® 100% Light Weight Metal Clad Composite Braid Nickel Plated 103-026

10 AmberStrand ® Data Sheet 103-026-xxx  Lubricating Oil Mil-L-23699 8 hrs @ 150°C, followed by 72 hrs @ 65°C  Isopropyl Alcohol 8 hrs @ 50°C, followed by 72 hrs @ 65°C  Cleaner Fluid Mil-C-85570 8 hrs @ 23°C, followed by 72 hrs @ 65°C  De-Icer Fluid AMS-1432 8 hrs @ 23°C, followed by 72 hrs @ 65°C  Fire Extinguishing Foam 8 hrs @ 23°C, followed by 72 hrs @ 65°C  R-134 Refrigerant 8 hrs @ 23°C, followed by 72 hrs @ 65°C Test results, Mil-Std 810F Method 504 (modified), for all Substances Listed Below: No fraying, DC resistance within limits (AS85049 paragraph 4.6.3)