Download presentation
Presentation is loading. Please wait.
Published byAlyson Parrish Modified over 9 years ago
1
Energy Analysis Department Coal-Wind Hybrid: Assumptions & Findings Coal-Wind Hybrid: Assumptions & Findings Amol Phadke, Ph.D. Lawrence Berkeley National Laboratory (AAPhadke@lbl.gov) 9/6/2007, 2007
2
Energy Analysis Department Outline of the Presentation Final Assumptions Testing the economic rationale of coal-wind hybrid Results for hybrid options Competitiveness of the hybrid with other options Conclusions
3
Energy Analysis Department Overview of the Analysis Developed a spread-sheet based model Identified possible hybrid configurations Finalized assumptions about technical parameters and costs Evaluated costs of different options with varying assumptions Today’s objectives -Review assessment of the hybrid options
4
Energy Analysis Department Economic Rationale for Coal-Wind Hybrid What is Coal-Wind Hybrid project? Economic rationale Improve the utilization of transmission lines Long distance transmission costs are significant Second best option to firm-up the wind Avoid wind integration and capacity costs
5
Energy Analysis Department Coal Wind Hybrid from an Economic Perspective
6
Energy Analysis Department Key Economic Considerations Tradeoffs between generation and transmission costs - Backing down of power generation unit: Increases generation costs per unit of output and reduces transmission costs Tradeoffs between fuel production and transmission costs -Lower capacity factor of the FT reactor
7
Energy Analysis Department Resource Options Considered Hybrid options -Hybrid with fuels production (SNG, Syncrude, methanol) -Syngas storage (system is sized lower than the power generation unit) -CCGT-wind hybrid, CT-wind Hybrid, Hypothetical Hybrid Benchmark -All Coal-wind hybrid options have 3000 MW of coal generation, 1500 MW wind generation, 3000 MW of transmission line Competing options -Stand alone coal, stand alone wind (with capacity overbuild), NGCC, PC, solar concentric power Options not considered -Advanced gas: cost of saved CO2 ~ $80/Ton, buying permits more economical -PC + CCS: More expensive than IGCC + CCS -IGCC without CCS: without CCS, IGCC does not offer economic advantages over PC. IGCC has lower emissions of mercury and sulfur and has lower water requirements
8
Energy Analysis Department Assumptions about Capital Costs and Technical Parameters Current costs expressed in 2006$ NETL estimates include recent run-ups in fossil plant costs NREL estimate (reference) of wind plant costs include recent run-ups in plant costs Technological performance (expected performance of plants coming online in 2010-2015 time horizon) -Capacity factor -Heat Rate
9
Energy Analysis Department Key Assumptions…I
10
Energy Analysis Department Fuel Prices Assumptions Natural Gas Prices -Annual energy outlook (AEO) forecast -Systematic difference between AEO & NYMEX futures ($0.78/MMBtu : Bolinger et. al) t Risk premium t Systematic bias t No convergence -NYMEX projected into future using escalation rate in AEO t Adjusted for delivery in the pacific region (by adding $.11/MMBtu) t Levelized natural gas price (2010-2030) of $7.10/MMBtu (2006$) t Cut off ranges explored Coal Prices -Levelized price (2010-2030) derived from AEO forecast of Wyoming Coal: $9.40/Short Ton : $0.55/ MMBtu -Cut off ranges explored
11
Energy Analysis Department Carbon Prices Assumptions Base Case $40/TonCO2: FEAST model assumption base case (assuming CA will meet its targets on its own: without buying offsets) Wide range of carbon prices (significantly driven by assumptions about offset prices and emission reduction target levels) Cutoff price estimated, high price scenario explored
12
Energy Analysis Department Key Assumptions: Transmission Feast Model Assumptions Base Case: AC + DC Transmission
13
Energy Analysis Department Key Assumptions, Financing
14
Energy Analysis Department Approach to Analyze the Economics of Fuel Production (SNG, Syncrude, Methenol) Adding a Fuel Facility -Allows a higher capacity factor for all the components in the system except the power generation unit -Lowers the capacity factor of the fuels plant Additional costs of fuel production are apportioned to the costs of power generation For example, in a Syncrude production facility -$737M required for FT which has a peak capacity of handling gas worth 1500 MW of output and runs @ 47% capacity factor -Same output can be produced by a FT which has a peak capacity to handle gas worth ~ 1500 MW, which costs $346M -Cost of FT that is paid by power generation $390M The costs of this configuration are cheaper compared to a configuration in which the entire IGCC unit is backed down to accommodate the wind output The economics of the fuels production facility is same as a stand-alone coal to liquids fuel production facility
15
Energy Analysis Department Additional Costs of Fuel Production Facilities
16
Energy Analysis Department Syngas Storage Option: Estimating Storage Requirements
17
Energy Analysis Department Variation in Storage Requirement Year to year and within month lower than the seasonal requirements for storage Variation in the seasonal storage requirements Storage costs assuming storage in depleted natural gas wells (cheapest option) Storage requirement 4stdev greater than the observed value
18
Energy Analysis Department EOR Revenue and Potential EOR revenues depend on the oil price Bilateral monopoly case EOR revenues will be shared in half: $15/MWh if EOR revenue = $30/MWh Total EOR potential in the RM region will absorb 70% of the CO2 emissions of the hybrid plant in its lifetime Average EOR revenue (adjusting for transpiration costs) $9.5/MWh Distance from different markets -For first few plants, sequestration costs will be zero
19
Energy Analysis Department Other key issues Ramp rate of FT is sufficient to accommodate variation in output due to wind ~ 3% reduction in the heat rate of hybrid options due to backing down of power generation unit Capacity equivalence costs are considered in scenario analysis 20% overbuilding of wind capacity results into ~ 15% increase in transmission utilization & 1.5 % reduction in wind capacity factor
20
Energy Analysis Department Results Comparing with other hybrid options -Wind-CCGT hybrid, wind CT Hybrid, wind-coal hybrid without fuels production -Sensitivity to fuel prices Comparing with the benchmark co-located coal-wind facility Comparing with competing options Sensitivity analysis -Transmission -Wind integration and capacity costs -EOR -Capacity equivalence costs -Fuel prices -Carbon prices -Capital costs
21
Energy Analysis Department Base Case Assumptions
22
Energy Analysis Department Comparing Hybrid Options: Coal-wind hybrid with fuel production or storage is the cheapest
23
Energy Analysis Department Testing the Economic Rationale of Coal-Wind Hybrid Stand alone coal, wind, and other hybrid options and are not the appropriate benchmarks, they are competing options -Total costs are influenced by generation costs in addition to transmission utilization -If stand alone wind generation is cheaper than coal, then Coal and Wind hybrid could be cheaper than coal simply because it is including wind generation Appropriate benchmark is -co-located coal-wind facility where the ratio of the coal to wind generation is the same as the hybrid system -Coal unit is operated at its full capacity factor -Enough transmission capacity to carry peak coal and 80% of the peak wind generation (since the wind capacity is overbuilt) -This hypothetical benchmark consist of ~2700 MW of coal, 1800 MWs of wind, and 4200 MWS of transmission capacity which results into a transmission utilization of 77% instead of 97% in the hybrid case -Coal generation 75%, wind generation 25%
24
Energy Analysis Department Costs and benefits of the coal wind hybrid option Benefits -Improved utilization of transmission t Compared to stand alone wind, stand alone coal, and the hypothetical co-located coal wind facility t Cycling leads to improved transmission utilization t An outage causes lower utilization of transmission. However, in the hybrid, the utilization of transmission is less affected by an outage. Outage is usually less than the backed down power generation in the hybrid [For an outage rate of 10%, transmission utilization is lowered by 3% instead of 10% in the stand alone coal case] -Improved utilization of the IGCC + CCS system t In the stand alone option, outage in the power generation unit requires backing down of gasifiers resulting into lower utilization of the air separation unit, gasifiers, pollution control equipment, carbon separation and capture equipment. In the hybrid, this is not the case. The output from the gasifieres can be diverted to the fuels plant -Avoided wind integration and capacity equivalence costs Costs -Lower utilization of the power generation unit -Additional costs of fuel production or syngas storage faculties
25
Energy Analysis Department Results: NPV of the benefits
26
Energy Analysis Department Comparison with competing options Base Case Sensitivity Analysis
27
Energy Analysis Department Results: Base Case
28
Energy Analysis Department Sensitivity Analysis: Conceptual Map
29
Energy Analysis Department Transmission Choice & Costs Wind costs affected by the transmission assumptions the most
30
Energy Analysis Department Effect of wind integration and capacity costs Stand alone wind more competitive if wind integration and capacity costs are negligible
31
Energy Analysis Department Effect of Natural Gas Prices At a price of about $5.5/MMBtu or below, CCGT is the cheapest option
32
Energy Analysis Department Effect of EOR Revenues: Net Carbon Costs Counting EOR makes stand alone coal the cheapest option
33
Energy Analysis Department Effect of Coal Prices Results are not very sensitive to coal prices
34
Energy Analysis Department Effect of Carbon Prices ~ $16/TonC02 or below, PC becomes the most attractive option
35
Energy Analysis Department Scenario where advanced coal and hybrid options are not cost competitive Low NG ($5/MMBty) and low Carbon ($20/MMBtu) Price
36
Energy Analysis Department Effect of Increase/Decrease in Capital Costs of Generation Technologies CCGT costs least affected
37
Energy Analysis Department Conclusions Coal-wind hybrid with fuel production or syngas storage is most economical among other hybrid alternatives (CCGT-wind hybrid, CT-wind Hybrid, and coal-wind hybrid without fuel production or storage) Coal-wind hybrid has economic merit and compared to a stand alone benchmark, savings range from ~ $300 M to $1500 Mover the life of the project Coal-wind hybrid is competitive with or more economical compared to -NGCC generation above a NG price $5.5/MMBtu (at a carbon price of $40/TonCO2) -PC generation above a carbon price of $16/TonCO2 -It is more economical than PC and NGCC based on prevailing expectations of the cost of generation technologies and fuel prices Stand-alone wind generation is more economical than NGCC generation in most scenarios Results are screening level: future work required for precise estimates
38
Energy Analysis Department Next steps Emission footprint Finalize first draft of the report Incorporate any suggested changes Comparison of qualitative advantages of different hybrid options