Published byLeon Harrell Modified over 9 years ago
2
Nexans Cabling Solutions, Jan 2004 1
3
Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics Cabling evolution Parameters Cat 6 versus Cat 5 Standardization – What is Deembedding? Nexans Solutions Class D/E/F, Essential Installation Issues/Installation practice FO theory/FO practice Tendencies in Structured Cabling / FTTW Agenda
4
Nexans Cabling Solutions, Jan 2004 3 Why Universal Cabling ? Cabling Evolution
5
Nexans Cabling Solutions, Jan 2004 4 Telephone Informatics Unstructured Structured Universal Cabling System Pre-engineered Cabling System Cabling Evolution
6
Nexans Cabling Solutions, Jan 2004 5 Telephony PABX Basic Star Structure: still applicable today Voice Grade Cable: not installed any more Cabling Evolution
7
Nexans Cabling Solutions, Jan 2004 6 Data networking (80 - 90) LAN introduction New cable media HO ST Cabling Evolution 10BASE5 Token Ring FDDI SAS DAS
8
Nexans Cabling Solutions, Jan 2004 7 Unstructured Each system had a different kind of transmission medium (UTP, STP, coax, twinax,...) The Solution installed is not compatible with other Solutions Costly moves and changes No overview Spaghetti cabling Cabling Evolution
9
Nexans Cabling Solutions, Jan 2004 8 Universal Cabling Two media: copper twisted pair and optical fiber Voice, data, video, control signals Patching Facilities Universal (Generic): application independent Cabling Evolution
10
Nexans Cabling Solutions, Jan 2004 9 I want to communicate with you No problem, I am conform with the OSI model Influence of applications on system performance requirements
11
Nexans Cabling Solutions, Jan 2004 10 TCP/IP = OSI-like Model Layer 1: physical layer Layer 3: Network Layer Layer 2: Data Link Layer Layer 4: Transport Layer IP Header Data Layer 3: Network Layer Ethernet Header Data Layer 2: Data Link Layer Layer 4: Transport Layer Layer 5-7: Higher OSI Layers TCP header Ethernet Header Data IP Header Data TCP header
12
Nexans Cabling Solutions, Jan 2004 11 Network Layer IP Header Data Layer 3: Network Layer TCP header Layer 4: Transport Layer Layer 5-7: Higher OSI Layers IP Header Data Layer 3: Network Layer TCP header Layer 4: Transport Layer Layer 5-7: Higher OSI Layers The Network Layer 3 addresses the interconnection of networks by routing packets from one network to another. To route packets across different networks we need a router
13
Nexans Cabling Solutions, Jan 2004 12 IP address (32 bits) 4 Bytes IP address 129. 60. 10. 70 Network Layer Primary function of IP : to provide an reliable, best effort, connectionless datagram delivery.
14
Nexans Cabling Solutions, Jan 2004 13 Data Link Layer IP Header Data Layer 3: Network Layer Ethernet Header Data Layer 2: Data Link Layer TCP header Layer 4: Transport Layer Layer 5-7: Higher OSI Layers IP Header Data Layer 3: Network Layer Data Layer 2: Data Link Layer TCP header Layer 4: Transport Layer Layer 5-7: Higher OSI Layers Ethernet Header This layer contains the MAC address (Medium access control) - Bridging or switching The data link layer must contain Length of the frames a means of addressing access control to the medium error detection (and correction)
15
Nexans Cabling Solutions, Jan 2004 14 3 Bytes MAC address 0 0 AA 00 32 2A 6B Supplier identification MAC address (48 bits) Influence of applications on system performance requirements
16
Nexans Cabling Solutions, Jan 2004 15 Layer 1 Layer 1: physical layer, the Cabling System IP Header Data Layer 3: Network Layer Ethernet Header Data Layer 2: Data Link Layer Layer 4: Transport Layer Layer 5-7: Higher OSI Layers TCP header Layer 3: Network Layer Layer 2: Data Link Layer Layer 4: Transport Layer Layer 5-7: Higher OSI Layers Ethernet Header Data IP Header Data TCP header
17
Nexans Cabling Solutions, Jan 2004 16 OSI Model Layer 1: physical layer This Layer addresses the physical characteristics of the network Types of cables used Types of connectors used Required Performance levels of the links and channels Max. length of the cables Defines the representation of bits (zero’s and ones) on the cable frequency, voltage, encoding techniquesencoding techniques The higher layers give a meaning to these bit values Layer 1: physical layer, the Cabling system
18
Nexans Cabling Solutions, Jan 2004 17 Ethernet10 Mbps 10 MHzManchester Encoding Technique The Network Interface Cards (NIC) translate the bits into voltage levels (Frequencies). The encoding technique compresses the bit stream so that high bit rate application can be transported over lower bandwidth links. Because of the fact that the transmission speed is depending on the encoding technique, we do not use the term Mbps to compare cables to each other, but we use MHz which is the parameter expressing the bandwidth of the cable. The physical Layer 1 is thus completely determined by the upper laying layers OSI Model: From bits to frequencies Layer 1: physical layer
19
Nexans Cabling Solutions, Jan 2004 18 Ethernet: The physical layer IEEE802.3 10BASE-T Twisted pair RJ45 100 m Manchester encoding 3V Class C link/channel performance required Influence of applications on system performance requirements
20
Nexans Cabling Solutions, Jan 2004 19 Gigabit Ethernet: The physical layer IEEE802.z 1000BASE-T Twisted pair RJ45 100 m PAM 5 encoding 3V Class D’99 link/channel performance required Class D’01 preferred Influence of applications on system performance requirements
21
Nexans Cabling Solutions, Jan 2004 20 Class C / Cat 3 Category 4 Category 5 / Class D Class E / Category 6 Class F / Category 7 16 MHz20 MHz100 MHz200 MHz 600 MHz Class D / Category 5 (+amendment) (Category 4) Standardisation : Universal Cabling
22
Nexans Cabling Solutions, Jan 2004 21 Facts about Nexans Technics Cabling evolution Parameters Cat 6 versus Cat 5 Standardization – What is Deembedding? Nexans Solutions Class D/E/F, Essential Installation Issues/Installation practice FO theory/FO practice Tendencies in Structured Cabling / FTTW Agenda
23
Nexans Cabling Solutions, Jan 2004 22 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
24
Nexans Cabling Solutions, Jan 2004 23 2000 rpm = ? km/h 2000 rpm = ? km/h Which one is faster ? Megabits or MegaHertz ?
25
Nexans Cabling Solutions, Jan 2004 24 CODING IS AN APPLICATION DEPENDENT NECESSITY !!! APPLICATIONMbps BandwidthEncoding Technique Ethernet10 Mbps 10 MHz(Manchester) Token Ring 4 & 16 Mbps 16 MHz(Manchester) Fast Ethernet100 Mbps 62,5 MHz(NRZI + 4B5B) TP-PMD 31,25 MHz(MLT-3 + 4B5B) ATM155 Mbps 78 MHz(NRZ) 1000BASE-T1000 Mbps 125 MHz(PAM-5) 100 Mbps x conversion factor = ??? MHz OSI Model: From bits to frequencies: Encoding Techniques X 1000BASE –TX 1000 Mbps 250 MHz(PAM-5) ATM 10001000Mbps 250 Mhz
26
‘ 80 Ethernet 10 Mb/s ‘85 Token Ring 16 Mb/s ‘93 FDDI 100 Mb/s ‘94 Fast Ethernet 100Mb/s ‘95 ATM 155 Mb/s ‘98 Gigabit Ethernet 1000 Mb/s Capability of Cabling Infrastructure Request of Bandwidth AN EFFICIENT CABLING SYSTEM HAS TO ANTICIPATE Cabling Evolution
27
Nexans Cabling Solutions, Jan 2004 26 Digital Signal Encoding 0100110100 NRZ-I Man
28
Nexans Cabling Solutions, Jan 2004 27 Influence of Noise Signal/Noise Ratio (SNR) is more important with higher levels of coding
29
Nexans Cabling Solutions, Jan 2004 28 We use km/h to express the speed of a car Use MegaHertz to express transmission speed !!! Megabits or MegaHertz ?
30
Nexans Cabling Solutions, Jan 2004 29 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
31
Nexans Cabling Solutions, Jan 2004 30 t Attenuation (Insertion loss) I a m t a l k i n g t o y ou ! Can y ou he a r me ? Attenuation
32
Nexans Cabling Solutions, Jan 2004 31 The amount of signal loss in the transmission link (expressed in dB) dB Loss Signal Source Signal Receiver t Attenuation Attenuation
33
Nexans Cabling Solutions, Jan 2004 32 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
34
Nexans Cabling Solutions, Jan 2004 33 t Near End Crosstalk (NEXT) Eric Bob Chris Dave Near End Crosstalk = NEXT is a measure of signal coupling from one pair to another pair.
35
Nexans Cabling Solutions, Jan 2004 34 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
36
Nexans Cabling Solutions, Jan 2004 35 ACR (dB)=NEXT (worst case) - attenuation (worst case) t Attenuation to crosstalk ratio (ACR) 60 dB 50 dB 40 dB 30 dB 20 dB 10 dB 10 100 20 80 30 4050607090 Frequency (MHz) ACR Minimal LANmark5/ Cat.5e350 link performance ISO/IEC IS 11801 specification ISO/IEC Nexans Cabling Solutions 70 dB 8.7 dB 16 dB Attenuation to Crosstalk Ratio
37
Nexans Cabling Solutions, Jan 2004 36 Rule : For high speed applications ACR of a link should be better than 13 dB at 100 MHz Fast Ethernet 100 Mbps Gigabit Ethernet 1000 Mbps ATM 155 Mbps Attenuation to Crosstalk Ratio
38
Nexans Cabling Solutions, Jan 2004 37 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
39
Nexans Cabling Solutions, Jan 2004 38 Focus on phenomena that will occur : during a simultaneous parallel transmission of data in both directions on all four pairs in the cable Simplex bi-directional transmission Full duplex bi-directional transmission on 4 pairs Technical Knowledge
40
Nexans Cabling Solutions, Jan 2004 39 Simplex bi-directional transmission (over 2 pairs) e.g. Ethernet, Token Ring ä attenuation ä NEXT ä ACR Full duplex bi-directional transmission (over 4 pairs) e.g. Gigabit Ethernet: ä PowerSum specs (PSNEXT, PSACR) ä ELFEXT, PSELFEXT ä Delay skew ä Return loss ä Coupling attenuation Technical Knowledge
41
Nexans Cabling Solutions, Jan 2004 40 1000 Mbps Full Duplex over 4 pairs ? ä 250 Mbps on each pair in both directions 1000 Mbps simultaneously in both directions Technical Knowledge
42
Nexans Cabling Solutions, Jan 2004 41 t Near End Crosstalk (NEXT) = NEXT is a measure of signal coupling from one pair to another pair. Near End Crosstalk
43
Nexans Cabling Solutions, Jan 2004 42 = NEXT coupling from 3 adjacent pairs transmitting simultaneously t PowerSum NEXT Alan Eric Geoff Bob Andres Franco Chris Dave PowerSum NEXT PowerSum NEXT
45
Nexans Cabling Solutions, Jan 2004 44 Powersum NEXT RX TX - + Need 4 of these PowerSum NEXT In Gigabit Ethernet : PowerSum NEXT will be cancelled out !
46
Nexans Cabling Solutions, Jan 2004 45 PowerSum ACR t Attenuation to Crosstalk Ratio ACR = NEXT - attenuation t PowerSum ACR PSACR = PSNEXT - attenuation ACR/PSACR is the signal to noise ratio considering NEXT/PSNEXT as the only noise sources.
47
Nexans Cabling Solutions, Jan 2004 46 60 dB 50 dB 40 dB 30 dB 20 dB 10 dB 20 200 40 160 60 80100120140180 Frequency (MHz) 70 dB t PS ACR Attenuation to Crosstalk Ratio LANmark 6 channel - 2 connectors LANmark 6 channel - 4 connectors ISO/IEC JTC 1/SC 25/WG 3 N568 specification 11.5 dB 7.4 dB 0.1 dB
48
Nexans Cabling Solutions, Jan 2004 47 Defined in the ISO and TIA standards Worst Case configuration Allows patching between patch panels High flexibility for modern office environments (zone wiring) Nexans offers 4x RJ45 connections Nexans’ Class E channel outperformes the standards The 4 Connector Channel Model
49
Nexans Cabling Solutions, Jan 2004 48 4 connector channel ACR
50
Nexans Cabling Solutions, Jan 2004 49 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
51
Nexans Cabling Solutions, Jan 2004 50 = is signal coupling from one pair to another pair, measured at the far end FEXT t Far End Crosstalk (FEXT) Far End Crosstalk Eric Dave Geoff Andres
52
Nexans Cabling Solutions, Jan 2004 51 = FEXT coupling from 3 adjacent pairs transmitting simultaneously t PowerSum FEXT PowerSum FEXT Eric Andres Alan Chris Geoff Bob Dave Franco PowerSum FEXT
54
Nexans Cabling Solutions, Jan 2004 53 t PowerSum ELFEXT PowerSum ELFEXT
55
Nexans Cabling Solutions, Jan 2004 54 t Equal Level FEXT ELFEXT = FEXT - attenuation t PowerSum ELFEXT PS ELFEXT = PSFEXT - attenuation = similar to ACR/PSACR, which is the signal to noise ratio considering NEXT/PSNEXT as the only noise, while ELFEXT/PSELFEXT expresses the signal to noise ratio considering FEXT/PSFEXT only. PowerSum ELFEXT
56
Nexans Cabling Solutions, Jan 2004 55 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
57
Nexans Cabling Solutions, Jan 2004 56 t Delay Skew Delay Skew I am to you talking I am talking to you
58
Nexans Cabling Solutions, Jan 2004 57 = is the difference in travel time on the 4 pairs (expressed in nsec) t Delay Skew Delay Skew
59
Nexans Cabling Solutions, Jan 2004 58 1000 Mbit Message 250 Mbps ABCD BDAC Delay Skew too high! = ???? = Delay Skew
60
Nexans Cabling Solutions, Jan 2004 59 Delay Skew : example < 50 nsec ä Channel with a delay Skew of more than 50 nsec cannot successfully support Gigabit Ethernet Delay Skew
61
Nexans Cabling Solutions, Jan 2004 60 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
62
Nexans Cabling Solutions, Jan 2004 61 t Return Loss = Return Loss (or Transmit Echo) is expressing the reflection of a signal on the same wire pair Return loss
63
Nexans Cabling Solutions, Jan 2004 62 t Return Loss ä A measure of the strength of reflected signal echoes ä Caused by impedance mismatches along a cable run ä Signal echo is an additional noise source Return loss
64
Nexans Cabling Solutions, Jan 2004 63 TX - + RX Return Loss In Gigabit Ethernet : Return Loss will be cancelled out ! Return loss
65
Nexans Cabling Solutions, Jan 2004 64 Megabits or MegaHertz ? ? ? Attenuation Near-End Crosstalk Attenuation to Crosstalk Ratio PowerSum Next, PowerSum ACR ELFEXT, PowerSum ELFEXT Delay Skew Return Loss Coupling Attenuation Electromagnetic Interference Technical Knowledge
66
Nexans Cabling Solutions, Jan 2004 65 Powersum NEXT Powersum ELFEXT Ambient noise t Noise sources Technical Knowledge Delay Skew Return Loss
67
Nexans Cabling Solutions, Jan 2004 66 ä Background noise such as noise generated by power lines, telephone voltages, airco’s or engines, … ä Due to its random nature, ambient noise can not be cancelled out in the NIC and it will contribute to the BER of a system t Ambient noise Ambient Noise
68
Nexans Cabling Solutions, Jan 2004 67 New parameter studied in European Standardisation (CENELEC) Included in last edition of ISO 11801 and EN 50173 Nexans is one of the pioneers in the work on coupling attenuation Measures the electromagnetic isolation between a disturbing source (ambient noise) and the cabling expresses the overall EMC performance of cabling Coupling Attenuation t Coupling attenuation
69
Nexans Cabling Solutions, Jan 2004 68 Sources of Electromagnetic Interference Engines Engines Elevators Elevators GSM GSM / Walkie Talkies 230 230 V cabling high high voltage cables Air Air conditioners TL TL lighting (HF) Heating Heating sources/ Micro waves/ radars Refrigerators Refrigerators Photocopiers Photocopiers Pencil Pencil sharpeners Light Light Dimmers EMI
70
Nexans Cabling Solutions, Jan 2004 69 Protection against ambient noise determined by Balance Screening Now specified by parameter COUPLING ATTENUATION Coupling Attenuation
71
Nexans Cabling Solutions, Jan 2004 70 Influence of Noise Signal/Noise Ratio (SNR) is more important with higher levels of coding
72
Nexans Cabling Solutions, Jan 2004 71 uncontrollable influence from the outside t Electromagnetic Interference (EMI) EMI
73
Nexans Cabling Solutions, Jan 2004 72 t Solution : Close the window, use a screen !!! EMI
74
Nexans Cabling Solutions, Jan 2004 73 antenna t 1) How does a radio pick up signals ? EMI
75
Nexans Cabling Solutions, Jan 2004 74 radiation t 2) Why is a mobile phone not allowed in hospitals, airplanes and in gasoline stations ? EMI
76
Nexans Cabling Solutions, Jan 2004 75 Faraday cage t 3) Why is the housing of a desktop in metal ? EMI
77
Nexans Cabling Solutions, Jan 2004 76 IMMUNITY OF TWISTED PAIR AT LOW FREQUENCIES EMI
78
Nexans Cabling Solutions, Jan 2004 77 IMMUNITY OF INSTALLED TWISTED PAIR AT LOW FREQUENCIES Bending EMI
79
Nexans Cabling Solutions, Jan 2004 78 EMI IMMUNITY OF INSTALLED TWISTED PAIR AT HIGH FREQUENCIES
80
Nexans Cabling Solutions, Jan 2004 79 Bending EMI IMMUNITY OF INSTALLED TWISTED PAIR AT HIGH FREQUENCIES
81
Nexans Cabling Solutions, Jan 2004 80 10 dB x better EMC performance ! EMI EMI 40 m 2 x 25 m Nexans’ dual foil cables Single foil FTP cables EMI
82
Nexans Cabling Solutions, Jan 2004 81 OVERALL SHIELD MADE OF TWO FOILS ! HIGHER EMC PERFORMANCES ! better Coupling Attenuation, better shield effectiveness GAIN ON INSTALLATION ! No risk to cut the foil off when stripping Only one foil to connect More flexible foils easier to manipulate Quick and reliable installation EFFECTIVE SOLUTION ! Easy connection of one overall foil provides EMC performances comparable to S-FTP. FTP Dual Foil 40 µm 2x 25 µm
83
Nexans Cabling Solutions, Jan 2004 82 EFFICIENCY OF THE FOIL Current flow in the foil “Skin effect” Thickness of the foil Internally induced currents Externally induced currents EMI
84
Nexans Cabling Solutions, Jan 2004 83 Nexans is the inventor and first developer of FTP, combining advantages of UTP and STP Nexans Cabling Solutions is the world leader in screened cabling solutions Full range of screened cables and connectivity, offering a full EMC cabling system Grounding and Earthing considered during design SCREENED CABLING TECHNOLOGY EMI