Download presentation
Presentation is loading. Please wait.
Published byDelilah Fleming Modified over 9 years ago
1
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Design Concept for a Transducer Holding System Suitable for use with the Ohmic Instruments Model UPDM-DT-1E Radiation Force Balance Craig E. Nelson - Consultant Engineer
2
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Strengths 1.Relatively sensitive 2.Reasonable dynamic range 3.Modest cost Weaknesses 1.Various useful force sensing targets are not available 2.Various useful measurement chambers are not available 3.A stream guard is not available 4.A variety of transducer holding devices are not available 5.The installed transducer support post is not adequate for precision Acoustic measurements such as hydrophone calibration Ohmic Instruments Model UPDM-DT-1E
3
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Upgrade Components and Features Required for Hydrophone Calibrations Work 1.Transducer Holding Assembly a.Adjustable with Precision b.Versatile c.Robust d.Semi-permanent Lockdown features 2.Stream Guard Assembly a.Easily installable and Removable b.Useable with a variety of Source Transducers 3.Convenient Features a.All Parts and Pieces to be Stowed Inside the UPDM Storage Case b.No modification to the UPDM-DT-1E should be required Ohmic Instruments Model UPDM-DT-1E
4
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Ohmic Instruments Radiation Force Balance Proposed Transducer Measuring Devices Overview
5
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Low Angle ¾ Front View – Thumb Nuts and Other Hardware Are Not Shown
6
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com ¾ Top View – Thumb Nuts and Other Hardware Are Not Shown Original Accessory Support Post is Retained Mounts with Existing Screw Holes
7
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com ¾ Side View – Thumb Nuts and Other Hardware Are Not Shown Robust and Flexible Jigging Setup
8
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Cutaway Side View – Thumb Nuts and Other Hardware Are Not Shown Sound Field is Illustrated Jigging Locks Down Rigidly
9
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Top View – Thumb Nuts and Other Hardware Are Not Shown Cutout for Force Target Support Bracket “Upgrade Kit” fits within the original platform envelope More Jigging can be installed on this side
10
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Ohmic Instruments Radiation Force Balance Proposed Transducer Measuring Devices Individual Components
11
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Ohmic Instruments Radiation Force Balance – Top Surface
12
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Stream Guard Assembly
13
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Force Sensing Cone – Panasonic Model V318 Source Transducer with Sound Field (in yellow) Panasonic Model V318 Sound Field
14
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Measurement Chamber - Standard Issue Black Rubber Sound Absorber on Sides and Bottom Deep Drawn Steel Shell
15
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Lower Rail Upper Rail Both rails have the same cross section
16
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Lower Carriage Assembly Upper Carriage Both rails have the same cross section Stainless Steel 1/2 in Diameter Support Rods Thumb Nuts and Other Hardware Are Not Shown
17
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Panasonic Model V318 Transducer Holder (Two Parts) Upper Cross Bar Thumb Nuts and Other Hardware Are Not Shown
18
Nelson Research, Inc. 2142 – N. 88 th St. Seattle, WA. 98103 USA 206-498-9447 Craigmail @ aol.com Summary 1.The Ohmic Instruments Ohmic Instruments model UPDM-DT-1E requires enhancement in order to be effectively used for hydrophone calibration and other QA related tasks 2.A set of components has been designed to substantially enhance the UPDM-DT-1E capabilities 3.The proposed “upgrade kit” will allow accurate hydrophone calibrations to be performed 4.The proposed “kit” can be easily modified or adjusted to allow a variety of useful quality assurance tasks 5.A lesser level of upgrade will not suffice for the intended purposes
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.