2011 Colorado Metal and Nonmetal Mine Rescue Contest July 12 th thru 14 th, 2011 Idaho Springs, Colorado
6
Goldrush Mine Map 3 rd Left Section Exhaust Fan 2 nd Left Section 1 st Left Section 2011 Colorado MNM Mine Rescue Contest 1 st Right Section 2 nd Right Section FAB
7
Team Map FAB Tent Team Name ______________ #____ 3 rd Left Section
8
Fresh Air Base Map FAB Tent Team Name ______________ #____ 3 rd Left Section
9
FAB Tent 2011 Colorado MNM Mine Rescue Contest XXXXXX Airtight DD Face Ankle Deep Waist Deep Water Chest Ankle Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Low Back or Roof Smoke Closed Battery Pump Help, Help !! Airtight Intense Heat Face X 18 Timbers X 20’ Line Curtain 6.5 % CH4 0.0 ppm CO 19.3 % O2 0.0 ppm NO2 0.5 % CH4 2,000 ppm CO 17.3 % O2 8.0 ppm NO2 0 % CH4 12 ppm CO 18.9 % O2 1.1 ppm NO2 0 % CH4 16 ppm CO 16.9 % O2 1.6 ppm NO2 0 % CH4 12 ppm CO 17.9 % O2 1.1 ppm NO2 3’ extent BC & Frames (when touched the patient wakes up) I think that I am OK. (say at least 2 times) The other 3 patients lying in the unsafe roof will also respond the exact same way 3 rd Left Section Knee Deep Decline
10
FAB Tent 2011 CO MNM MR JUDGES MAP XXXXXX Airtight DD Face Ankle Deep Waist Deep Water Chest Ankle Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Smoke Closed Battery Pump Help, Help !! Airtight Intense Heat Face X 18 Timbers X 20’ Line Curtain 6 D C B A 3 12 4 3’ extent 5 78 6.5 % CH4 0.0 ppm CO 19.3 % O2 0.0 ppm NO2 0.5 % CH4 2,000 ppm CO 17.3 % O2 8.0 ppm NO2 0 % CH4 12 ppm CO 18.9 % O2 1.1 ppm NO2 0 % CH4 12 ppm CO 17.9 % O2 1.1 ppm NO2 0 % CH4 16 ppm CO 16.9 % O2 1.6 ppm NO2 3’ extent 1 1010 9 1212 1414 1313 1515 1717 1616 1818 1919 2020 2 2121 D&I Gas Test 7 Team Stops BC & Frames (when touched the patient wakes up) I think that I am OK. (say at least 2 times) The other 3 patients lying in the unsafe roof will also respond the exact same way 3 rd Left Section Knee Deep Decline Low Back or Roof
11
FAB Tent 2011 Colorado MNM Mine Rescue Contest Vent 1 XXXXXX Airtight DD Face Knee Deep Waist Deep Water Chest Ankle Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Closed OPEN Battery Pump Help, Help !! Airtight Intense Heat Face X 18 Timbers X 20’ Line Curtain 6.5 % CH4 0.0 ppm CO 19.3 % O2 0.0 ppm NO2 0.5 % CH4 2,000 ppm CO 17.3 % O2 8.0 ppm NO2 0 % CH4 12 ppm CO 18.9 % O2 1.1 ppm NO2 0 % CH4 16 ppm CO 16.9 % O2 1.6 ppm NO2 0 % CH4 12 ppm CO 17.9 % O2 1.1 ppm NO2 3’ extent (when touched the patient wakes up) I think that I am OK. (say at least 2 times) The other 3 patients lying in the unsafe roof will also respond the exact same way R R Last Build 3 rd Left Section Both regulators get sealed before venting Ankle Deep Decline Low Back or Roof
12
FAB Tent 2011 Colorado MNM Mine Rescue Contest Vent 1b XXXXXX Airtight DD Face Knee Deep Waist Deep Water Chest Ankle Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Closed Battery Pump Help, Help !! Airtight Intense Heat Face X 18 Timbers X 20’ Line Curtain 6.5 % CH4 0.0 ppm CO 19.3 % O2 0.0 ppm NO2 0.5 % CH4 2,000 ppm CO 17.3 % O2 8.0 ppm NO2 0 % CH4 12 ppm CO 18.9 % O2 1.1 ppm NO2 0 % CH4 16 ppm CO 16.9 % O2 1.6 ppm NO2 0 % CH4 12 ppm CO 17.9 % O2 1.1 ppm NO2 3’ extent (when touched the patient wakes up) I think that I am OK. (say at least 2 times) The other 3 patients lying in the unsafe roof will also respond the exact same way R R Last Build 3 rd Left Section Closed Both regulators get sealed before venting Ankle Deep Decline Low Back or Roof
13
FAB Tent 2011 Colorado MNM Mine Rescue Contest Vent 2 XXXXXX Airtight DD Face Roofed Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Closed CLOSED Battery Pump Help, Help !! Airtight Intense Heat Face X 18 Timbers X 20’ Line Curtain 6.5 % CH4 0.0 ppm CO 19.3 % O2 0.0 ppm NO2 0.5 % CH4 2,000 ppm CO 17.3 % O2 8.0 ppm NO2 0 % CH4 12 ppm CO 18.9 % O2 1.1 ppm NO2 0 % CH4 12 ppm CO 17.9 % O2 1.1 ppm NO2 3’ extent (when touched the patient wakes up) I think that I am OK. (say at least 2 times) The other 3 patients lying in the unsafe roof will also respond the exact same way R R 3 rd Left Section Both regulators get sealed before venting Decline Low Back or Roof
14
FAB Tent 2011 Colorado MNM MR PILLAR Layout XXXXXX Airtight DD Face Knee Deep Waist Deep Water Chest Ankle Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Smoke Closed Battery Pump Help, Help !! Airtight Intense Heat Face X 18 Timbers X 20’ Line Curtain 0.5 % CH4 2,000 ppm CO 17.3 % O2 8.0 ppm NO2 0 % CH4 12 ppm CO 18.9 % O2 1.1 ppm NO2 0 % CH4 16 ppm CO 16.9 % O2 1.6 ppm NO2 0 % CH4 12 ppm CO 17.9 % O2 1.1 ppm NO2 3’ extent 0’ 30’ 15’ 40’ 55’ 65’ 75’ 95’ 105’ 85’ 120’ 145’ 130’ 155’ 0’5’15’65’40’55’30’80’90’95’ Ankle Deep Decline Low Back or Roof 6.5 % CH4 0.0 ppm CO 19.3 % O2 0.0 ppm NO2
15
FAB Tent 2011 Colorado MNM MR PLACARD Layout XXXXXX Airtight DD Face Knee Deep Waist Deep Water Chest Ankle Air Clear X Self Rescuer X Battery Pump Closed Help! (burned hand) BBB XXXXXX Airtight XXXXXX Unsafe Rib Face Smoke Closed Battery Pump Help, Help !! Airtight Face X 18 Timbers X 20’ Line Curtain 3’ extent 0’ 30’ 15’ 40’ 55’ 65’ 75’ 95’ 105’ 85’ 120’ 145’ 130’ 155’ 0’5’15’65’40’55’30’80’90’95’ Decline Ankle Deep Low Back or Roof 2 1 4 3 8 7 6 5 Entry #1Entry #2Entry #3Entry #4 10 9 11 12 13 14 15 18 16/17 19 20 24 23 22 21 25/26 30 29 28 27 32/33 34 31 35 37 36 38 39 41 40 47 48 43 42 44 45/46 54 49 53 52 50/51 59 58 57 56 55 6061 62 63 64 68 67 69/70 65/66 75 71 74 72/73 77 76 78 79/80 16’ 48’ 20’ 25’ 113’ 83’ 65’ 152’ 142’ 132’ 155’ 25’ 50’ 48’ 45’ 65’ 75’ 96’ 104’ All Chest H20 1’ off pillar lines 107’ 14’ 20’ 42’ 90’ 80’ 138’ 121’ 146’ 150’ All unsafe roofs are 5’ wide & 5’ offset 42’ 52’ 47’ 60’ 70’ 85’ 96’ 153’ 142’ 135’ 130’ 5’ Doors and Barricades are in center of pillars Unless shown placards are 1’ off the rib line (objects) Placards for conditions shown from rib to rib go in center of entry or X- cut 0’ 10’15’20’ 25’ 0’ 12’ 17’ 22’ 5’ 7.5’