1 Herzlich Willkommen Bienvenue Welcome JUMO eTRON M 100 according to data sheet 70.1061 Electronic 2-channel microstat Klaus Otto

2 2 JUMO eTRON M 100 2-channel microstat JUMO eTRON M 100 model 70.1061 Electronic 2-channel microstat  Special version model 70.1061  2 analog inputs  Maximum 4 relays  The inputs can be freely assigned to the relays.  Operation only via keys (no setup)

3 3 JUMO eTRON M 100 2-channel microstat Block diagram JUMO eTRON M 100 Model 70.1061 Input 1: Pt100 / Pt1000 KTY11-6 / KTY2X-6 AC/DC 12…24 V +15 / -15 %, 48…63 Hz Binary input: No function Key inhibit Display switch-off Relay outputs: K1 changeover 16 A / 250 V K2 make 8 A / 250 V K3 make 8 A / 250 V Input 2: Pt100 / Pt1000 KTY11-6 / KTY2X-6 Option 1: K4 changeover 16A / 250 V or buzzer

4 4 JUMO eTRON M 100 2-channel microstat Configuration Enter code 72 with key Acknowledge with key Enter configuration level The parameters can be selected with keys and Press key > 3 seconds

5 5 JUMO eTRON M 100 2-channel microstat Contact functions  The maximum 4 relays can be freely assigned to both measurement inputs.  For each relay the functions direct (cooling) or inverse (heating) can be selected and a setpoint with hysteresis can be set.  For relays 2…4 the switching function („absolute“ = fixed switching point or „relative“ = switching point depends on the setpoint) can additionally be selected.

6 6 JUMO eTRON M 100 2-channel microstat Cooling (switching operation) With fixed setpoints (absolute)

7 7 JUMO eTRON M 100 2-channel microstat Heating (switching operation) With fixed setpoints (absolute)

8 8 JUMO eTRON M 100 2-channel microstat Relative switching function K2 to K4

9 Auf Wiedersehen Au revoir Good Bye Thank you very much for your attention!