Presentation is loading. Please wait.

Presentation is loading. Please wait.

STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)

Similar presentations


Presentation on theme: "STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)"— Presentation transcript:

1 STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)

2 Concept of FPC FPC consists of two instruments FPC-G: Focal plane guiding camera FPC-S: Near infrared camera for scientific observation FPC-S has a back up function of FPC-G FPC-G and S must have a same FOV and pixel scale with same detector. 1K x 1K InSb array (25  m pixel) ROIC developed for MIRI/JWST by Raytheon 5 arc-minutes FOV for 1 frame 0.3 arc-second FOV for 1 pixel (~diffraction limit at 5  m)

3 Detector proposed by Raytheon Format: 1024 x 1024 active (plus two columns of reference pixels) Pixel Pitch: 25 μm Input Circuit: SFD (source follower per detector) Active Fill Factor: > 98% Spectral Response: 0.4-5.3 μm Average Quantum Efficiency: > 90% (1 - 5 μm) Typical Response Uniformity: ≤ 5% (1σ) Average Dark Current: ≤ 0.02 e-/sec at 30 K Read Noise: 25 ~ 30 e - for single CDS (~20 e - for 0.4 Hz eadout) Power Dissipation: 0.5 mW (0.4 Hz readout), 1.2 mW ( 1Hz readout) Well Capacity: 2x10 5 e- Outputs: 4 Reset Modes Global Reset or reset by Row pair Operating temperature>10 K

4 Optical design of FPC-G Optical axes of lens group are shifted to improve off axis image 7 lenses with 4 aspherical surfaces Lens materials are ordinary used ones Spot size ( I and z band) is typically 10  m. Maximum size is ~35  m at a far end from the telescope axis Distortion effect can be corrected by interpolation formula.

5 Structure of FPC-G Cross sectional view of FPC-G Weight ~ 4kg (Support structure and FPA are not included)

6 Performance of FPC-G Required accuracy of the determination of centroid: 0.05 arcsec Wavelength band: I band (0.8  m) Detection limit: 18.6 mag (1Hz read out, 25  ) Number of stars in 1 frame: ~12 stars (GSCII Catalog) FPC-G can achieve required accuracy Power dissipation 1.2 mW (1 Hz readout), 0.5 mW (0.4 Hz readout)

7 Optical design of FPC-S FPC-S covers wavelength range from 0.5  m to 5 m  one more optical element a little longer than previous design (520 mm)

8 Spot diagram for white light (0.8-5  m) Typical spot size 24  m Max spot size31  m For monochromatic light 2-5  m max spot size ~34  m 0.8-2  m max spot size ~42  m Distortion effect can be corrected by interpolation formula. Error of centroid for 4’x4’ field is average:0.03”, Max 0.06” Error of centroid for 5’x5’ field is average:0.07”, Max 0.37”

9 Structure of FPC-S Weight ~ 6kg (Support structure and FPA are not included) Filter wheel10 positions (blank, diffuser, 8 filters)

10 New mode: LVF Spectroscopy Three LVFs (Linear Variable Filter) are installed on the filter wheel cf. 0.8-1.6, 1.4-2.8, 2.5-5 LVF has transmission depending on the physical position (scanning direction). Wavelength coverage is factor 2 Wavelength resolution is ~ 50. http://www.lwecorp.com/product-literature/lvf_ds_co_ae_042506.pdf Slit less spectroscopy at the wavelength range from 0.8 to 5  m Combined with slow scan, surface spectroscopy can be done efficiently for diffuse extended source Scan direction ↓ ← 5 arc-minute →LVF 0.8  m 1.6  m

11 Expected performance of FPC-S Assumed parameters Telescope3-m aperture (7m 2 ) Efficiency0.5 (Optical + quantum efficiency) Read out noise20 e - image size4 pixels 3  detection limit for point sources (100 sec integration, R~5) 26.3mag(AB) for all bands Vega magnitude J(1.25  m)H(1.6  m)K(2.2  m)L(3.5  m)M(5.0  m) 25.524.824.423.423.0 Photon noise becomes dominant for integration time lon ger than 100 sec 3  detection limit for surface brightness (100sec integration, R~5) 81 nW.m -2.sr -1 3  detection limit fro LVF mode, R~50, integration time ~t Point sources, F 3.4x10 -16. -2.t -1 W.m -2.  m -1 Extended source,.F 8.1x10 4. -1.t -1 nW.m -2.sr -1 Line intensity for point source6.84x10 -18. -1.t -1 W.m -2 Line intensity for extended source1.62x10 3. -1.t -1 nW.m -2.sr -1

12 Comparison with JWST Larger field of view JWST2.2x4.4 arcmin FPC-SPICA5x5 arcmin Much larger throughput x 20 of JWST Capability of surface spectroscopy New science that can not be done with JWST will be possible


Download ppt "STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)"

Similar presentations


Ads by Google