1 World Class Leaders in Fire Detection for over 75 years

2 HP900  New Proposed Features

3 HP900

4

5 Printouts -Event Store This will allow a selective printout from the Event Store for a particular loop or a particular condition i.e. Fires,Faults etc. This will still allow the complete Event store to be printed.

6 EVENT STORE PRINTOUT HP900

7 EVENT STORE PRINTOUT HP900

8 EVENT STORE PRINTOUT NOTE IF ENABLE IS PRESSED THEN THE COMPLETE EVENT STORE IS PRINTED HP900

9 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

10 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

11 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

12 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

13 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

14 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

15 EVENT STORE PRINTOUT NOTE THE ENABLE/DISABLE KEY TOGGLES SELECTION HP900

16 EVENT STORE PRINTOUT NOTE IF ENABLE IS PRESSED THEN ALL LOOPS ARE PRINTED USING THE PREVIOUS SELECTED OPTIONS HP900

17 EVENT STORE PRINTOUT NOTE IT IS POSSIBLE TO SELECT A PARTICULAR LOOP HP900

18 EVENT STORE PRINTOUT NOTE IT IS POSSIBLE TO SELECT A PARTICULAR LOOP HP900

19 EVENT STORE PRINTOUT NOTE IT IS POSSIBLE TO SELECT A PARTICULAR LOOP HP900 ENABLE KEY

20 Printing Event Store from the Fire Panel HP900

21 Printouts -Event store (Marked Events) The events are marked within the event store, so it is necessary to mark the events before setting “PRINT MARKED EVENTS ONLY” to “ON”

22 MARKING EVENTS WITHIN THE EVENT STORE HP900

23 MARKING EVENTS WITHIN THE EVENT STORE HP900

24 MARKING EVENTS WITHIN THE EVENT STORE NOTE THE DISABLE KEY WILL MARK ALL EVENTS PREVIOUS TO CURRENT EVENT HP900 DISABLE KEY

25 MARKING EVENTS WITHIN THE EVENT STORE NOTE THE ASTERIX SHOWS THAT EVENT HAS BEEN MARKED HP900

26 MARKING EVENTS WITHIN THE EVENT STORE NOTE THE DISABLE KEY WILL UNMARK ALL EVENTS PREVIOUS TO CURRENT EVENT HP900 DISABLE KEY

27 MARKING EVENTS WITHIN THE EVENT STORE NOTE NOW A BLOCK OF EVENTS HAS BEEN MARKED BETWEEN EVENT 150 AND 200. HP900

28 MARKING EVENTS WITHIN THE EVENT STORE NOTE THE ENABLE KEY WILL MARK ONE EVENT AT A TIME HP900 ENABLE KEY

29 MARKING EVENTS WITHIN THE EVENT STORE NOTE THIS EVENT IS NOW MARKED, AS WELL AS THE PREVIOUSLY DEFINED BLOCK HP900

30 Printouts -Status In addition to the current information this will show if a device is Enabled or Disabled, if a device is disabled for a period of time when the automatic enablement will take place. Sensor delay time would also be shown.

31 STATUS PRINTOUT HP900

32 STATUS PRINTOUT HP900

33 STATUS PRINTOUT NOTE IF ENABLE IS PRESSED THEN THE STATUS OF ALL THE DEVICES ARE PRINTED HP900

34 EVENT STORE PRINTOUT NOTE IT IS POSSIBLE TO SELECT A PARTICULAR ZONE HP900

35 EVENT STORE PRINTOUT NOTE IT IS POSSIBLE TO SELECT A PARTICULAR ZONE HP900 ENABLE KEY

36 Printing from the Fire Panel HP900

37 Recalibration time At present the sensors are recalibrated at the time the system is powered up, this new feature will allow the user to set the time for recalibration to occur.

38 Recalibration HP900

39 Recalibration HP900

40 Recalibration NOTE 24 HOUR CLOCK 30 MINUTE STEP HP900

41 Recalibration NOTE 24 HOUR CLOCK 30 MINUTE STEP HP900

42 Day/ Night mode This feature will allow each sensor to be selected to be on Day/Night Mode. The Day/Night Mode allows reduced sensitivity during a user defined time period.

43 HP900 Networking - Time Each panel on the network has its own real time clock, this new feature would allow the real time clock to be set by any panel on the network. Setting the time on one panel, will set the time on all the panels on the network.

44 HP900 Networking - Alerts This would allow a fire on any panel on the network to put any other panel on the network in the Alert condition.

45 HP900 Networking - Common Zones This allows each panel on the network to have zones that are common with other panels on the network. This allows a stairwell to be in one zone within a building when each floor has a separate control panel.

46 HP900 Networking - Cause & Effects This will allow Cause & Effects across the network, this gives the user the capability of 99 virtual wires across the whole network.

47 HP900 VIRTUAL WIRE 1 VIRTUAL WIRE 2

48 HP900 Time & Date This would prevent the control panel from losing the time and date when power is removed from the panel.

49 HP900 Test Key The function of the Test key will be expanded to work on the Event Store, so it will toggle the bottom line between Event Time/User Text/Device Type and Fault Code if the Event was a fault.

50 USING THE TEST KEY WITHIN THE EVENT STORE HP900

51 USING THE TEST KEY WITHIN THE EVENT STORE HP900

52 USING THE TEST KEY WITHIN THE EVENT STORE NOTE THE TEST KEY WILL TOGGLE THE BOTTOM LINE. HP900 TEST KEY

53 USING THE TEST KEY WITHIN THE EVENT STORE NOTE THE TEST KEY WILL TOGGLE THE BOTTOM LINE. ( USER TEXT) HP900 TEST KEY

54 USING THE TEST KEY WITHIN THE EVENT STORE NOTE THE TEST KEY WILL TOGGLE THE BOTTOM LINE. (ENGLISH TEXT OF FAULT) HP900 TEST KEY

55 USING THE TEST KEY WITHIN THE EVENT STORE NOTE THE TEST KEY WILL TOGGLE THE BOTTOM LINE. (DEVICE TYPE) HP900

56


Download ppt "World Class Leaders in Fire Detection for over 75 years."

Similar presentations


Ads by Google