OBJECTIVES 1. Explain the benefits of certifying cable installations. 2. Differentiate between a channel and a basic link. 3. Identify standard tests that should be performed on CAT5 cable runs to certify them. 4. Describe the functions typically associated with cable testing instruments. 5. Describe the steps associated with testing and certifying basic links and channels.
3
Figure 6-1: Basic Link and Channel Lengths
4
Table 6-1: Maximum Horizontal Cable Lengths
5
Table 6-2: Workmanship’s Impact on Channel Performance
6
the Wire Map test TIA/EIA specifications, as outlined in TSB 67, require that four different tests be performed on CAT5 runs immediately after the cable is pulled, and terminated, in order to meet the certification guidelines and to avoid having to troubleshoot certain types of problems later. The four specified tests are: the Length test the Attenuation test the NEXT test
7
the Power Sum NEXT test Several additional tests that may be required under certain circumstances include: the ELFEXT test the Power Sum ELFEXT test the Structural Return Loss (SRL) test the Attenuation-to-Crosstalk Ratio (ACR) test
8
Figure 6-2: WireScope 155
9
Table 6-3: Industry Standards Performance Comparison (Worst-Case Channel Performance @ 100 MHz) * New requirements addressed in TSB95
10
NEXT test must be performed at both ends of the run. Simple Rules for Testing: Documentation of test results must be included. Cabling/components must not be moved during testing, or retesting will be required. End-user patch cords must be tested in place. It is suggested that patch cords be 3 meters, but this subject does not as yet fall into the scope of the TIA/EIA T568A standards. It is expected that future releases will deal with this issue.
11
Figure 6-3: Simple Cable Tester
12
Before and after installation checkout The various features for this tester include: Easy one-step operation 14 LEDs to confirm testing status Shuts off automatically to maximize power saving Tests for shorts, connections, non-parallel wiring, and 25/50-ohm BNC terminations Requires a 9-volt battery
13
Figure 6-4: Fluke AT5 Tester
14
Figure 6-5: Wavetek CAT5 Tester
15
Figure 6-6: Microtest CAT5 Scanner and 2-Way Injector
16
LAB 16 OBJECTIVE Calibrating and Self-Testing Level II Testers To understand the procedure for properly calibrating the Level II testers, performing the self test, and documenting the test results
17
Several warnings are listed in the manual that indicate the possibility of causing the meters to give erroneous test results. Become familiar with these error-causing situations. TIP
18
Figure 6-7: Locating the Special Functions Menu
19
Figure 6-8: Self Calibration Ready
20
Figure 6-9: Connecting the Calibration Cable
21
After a slight delay, during which time the control unit reports that the self- calibration procedure is in progress (and various clicks and beeps can be heard), the control unit will display the “SELF CALIBRATION COMPLETE” message. TIP
22
Figure 6-10: Message Display in the Control Unit
23
The screen menu returns to the SPECIAL FUNCTIONS display. Always remember to calibrate the Level II testers before using them. TIP
24
The Self Test function of the Level II testers is used to check the operation of both the control unit and the remote unit. It’s a good idea to run this test periodically, as well. TIP
25
Figure 6-11: Self Test Ready
26
After a slight delay, during which time the control unit reports that the self-test procedure is in progress (and various clicks and beeps can be heard), the control unit will display the “SELF TEST PASS” message. TIP
27
Figure 6-12: Display Screen for SELF TEST PASS
28
While the control unit is still displaying the SPECIAL FUNCTIONS screen, it would be a good idea to check the Battery Status function. Because the control unit was charged just prior to performing this procedure, it should indicate that fact during a check. TIP
29
Figure 6-13: Display Screen for BATTERY STATUS
30
If the status of the battery ever drops to a value such that the Level II testers would not operate properly, there will be a specific warning message displayed on the screen. TIP
31
Figure 6-14: Changing the Display to Read NVP = 50%
32
Figure 6-15: Cable NVP Test Results Screen
33
Figure 6-16: Cable Length Test Results Screen
34
Figure 6-17: Changing the Display to Read NVP = 99.9%
35
LAB 16 QUESTIONS When should the various cables be plugged into the Level II testers? 1
36
LAB 16 QUESTIONS How long should the Level II testers be charged, according to the users manual? 2
37
LAB 16 QUESTIONS What three measurements are taken during a self test between the control unit and the remote unit? 3
38
LAB 16 QUESTIONS When plugging a cable into the Level II testers, which unit (control or remote) should be connected first? 4
39
LAB 16 QUESTIONS How long is the cable that is used to calibrate the Level II testers? 5
40
LAB 16 QUESTIONS Under what circumstances should the Level II testers be calibrated? 6
41
LAB 16 QUESTIONS How long does the self-calibration test take to complete? 7
42
LAB 17 OBJECTIVE Setting Up Level II Testers To understand the procedure for properly setting up the Level II testers, and documenting the results
43
Not all of the adjustable parameters displayed need to be tinkered with. Once some settings have been selected, they can normally be ignored from then on. Settings that may require periodic changes involve the particular test standard to be run and the type of cable to be tested. TIP
44
Figure 6-18: Page 1 of SETUP Menu
45
Notice that the very first parameter displayed is the TEST STANDARD, CABLE TYPE, because it is the parameter that most often needs to be adjusted. TIP
46
Notice that the bottom of the display indicates which of the four numbered buttons to press for the desired screen. You should now see the SELECT TEST STANDARD screen. TIP
47
You should now be looking at the SELECT CABLE TYPE screen. TIP
48
The control unit returns to the Page 1 display with the selections you just made highlighted. Any tests conducted at this point would expect to see CAT5 100-ohm UTP cable connected to the Level II testers. TIP
49
This parameter allows the user to edit the identification information that will appear in any reports that are generated by the Level II tester. TIP
50
Figure 6-19: Edit Screen for REPORT IDENTIFICATION
51
Report identification parameters that can be edited include the CUSTOM HEADER, the OPERATOR, and the testing SITE. Normally, there will be some existing text that was input from another technician or student. TIP
52
An alphanumeric listing appears, along with an edit box for the CUSTOM HEADER, containing the previously input text. In order to input the desired text in the editing box, you can use the arrow keys to select a character from the alphanumeric display. Then, use the direction arrow button (1) to select where the character will appear and press the ENTER key. Alternately, you can select an existing character position, and use the INC or DEC buttons to move up or down the alphanumeric list to the desired character. The Delete button (4) will delete the character immediately to the left of the cursor. TIP
53
Figure 6-20: Edit Screen for CUSTOM HEADER
54
The control unit returns to the REPORT IDENTIFICATION screen. TIP
55
If you receive any message regarding the fact that the selected parameter has been used to generate a report, and you don’t wish to delete the existing information, simply press the NEW button (2) to add another line of text. TIP
56
This means that there are no temperature- dependent limits that would affect the attenuation parameters using this cable. If temperature was an important factor in the use of the selected cable, you could use the CHOICE button (1) to select an average cable temperature that accurately reflected the actual conditions under which this cable was required to operate. Notice that if you press the CHOICE button (1) at this time, nothing happens! TIP
57
Figure 6-21: Edit Screen for REMOTE END TESTING
58
This setting enables you to use the remote unit to measure NEXT and ACR parameters from the far end of the cable under test, provided the test standard selected requires them. Keep in mind that the only time the remote unit is used is when testing twisted pair cable. TIP
59
Figure 6-22: Screen for Page 2 of SETUP
60
Normally, when the Level II testers are used in the field, the results of the various tests that are conducted need to be recorded, and printed, in order to provide the customer and the installer with copies. TIP
61
Figure 6-23: Edit Screen for BACKLIGHT TIME-OUT
62
This screen enables you to specify how long the control unit will allow the backlight to operate before shutting it off. Unless you were a cable installer doing work in a dark wiring closet, there would be no reason to operate the backlight during normal daylight. To conserve the charged batteries, make sure the setting shows 1 Minute. This will turn the backlight off after the control unit detects 1 minute of inactivity. Better yet, conserve even more power by not pressing the WAKE UP button at all, and keeping the backlight off. TIP
63
Figure 6-24: Edit Screen for POWER DOWN TIME-OUT
64
Again, you have several timing choices displayed. This parameter has to do with powering down the display altogether when the control unit detects inactivity. This is another way that the meter conserves its limited battery power. When the meter shuts down the display, it broadcasts an audible signal. The control unit does not forget where it is when it shuts down. To activate the unit once it shuts down, simply press its ENTER key. TIP
65
This measurement allows the monitoring of electrical noise, on lines 3 and 6 (pair 2 for T568A), that may be present on a twisted- pair cable. The control unit samples the voltage on the test pair once each second, and records any noise that exceeds this setting as a hit. For 10baseT purposes, 2 hits within a 10-second time span is interpreted as a failure. The default threshold for the control unit is 270 mV, and can be adjusted in 10m V increments. TIP
66
Figure 6-25: Screen for Page 3 of SETUP
67
You will see settings for handling the serial printing functions available with the control unit. These include PRINTER TYPE, SERIAL PORT BAUD RATE, and FLOW CONTROL. Unless your instructor is planning on printing out reports for your class activities, do not change these settings. The remaining setting on this page is for the AUDIBLE TONE. TIP
68
Figure 6-26: Screen for Page 4 of SETUP
69
Figure 6-27: Screen for Page 5 of SETUP
70
LENGTH UNITS: Feet (ft) Using what you have already learned, adjust the following settings, if necessary. NUMERIC FORMAT: 00.0 LANGUAGE: English POWER LINE FREQUENCY: 60 Hz
71
Figure 6-28: Screen for Page 6 of SETUP
72
SHIELD TEST: Enable Using what you have already learned, adjust the following settings, if necessary. CONFIGURE CUSTOM CABLE: * Custom\ Cable 1 * MAXIMUM FREQUENCY: 100 MHz CABLE INSIDE CONDUIT: N/A
73
The CONFIGURE CUSTOM CABLE setting enables the user to set up the control unit for testing cables that possess other than standard parameters. You may look through the various screens that are used to define a custom cable, but there is no need to make any changes to the information you see. TIP
74
LAB 17 QUESTIONS When does the audible tone sound on the Level II testers? 1
75
LAB 17 QUESTIONS What type of cable would you use the remote unit to test? 2
76
LAB 17 QUESTIONS What is the primary use of the control unit’s backlight feature? 3
77
LAB 17 QUESTIONS How do you reactivate a control unit that has powered down in order to conserve battery power? 4
78
LAB 17 QUESTIONS Why would it be necessary for the results of the various tests that are conducted by the Level II testers to be recorded and printed? 5
79
LAB 18 OBJECTIVE Autotesting Patch Cables on Level II Testers To understand the procedure for autotesting previously created patch cables using the Level II testers, and documenting the results
80
Notice that the information provided for the Autotest functions is divided between those designed for twisted pair cable and those designed for coaxial cables. Although the tests conducted for unshielded and shielded twisted pair are identical, the shielded variety is also tested for continuity along the shield. TIP
81
Figure 6-29: Autotest Wiring Diagram for Jack Terminations
82
Figure 4-29 displays a near minimum configuration. A minimum configuration would consist of only one cable. Keep in mind that the cables could be shown routed through a patch panel, wall plate, or various wiring closets. One thing to realize is that the Level II testers will not run an Autotest on twisted pair cable, unless a remote unit (or control unit operating in SMART REMOTE mode) is connected at one end of the wire run. TIP
83
The idea here is to examine the wiring condition of the cable you created in Lab 4. Because the other two cables are known to be good, any problems that occur should be traced to the cable under test. TIP
84
The remote unit will emit several audible tones. TIP
85
Always check to be sure that there are no BNC cables attached to the control unit when testing twisted pair cabling. TIP
86
The control unit will emit several audible tones. TIP
87
Depending on the wiring setup and the battery condition of the Level II testers, several things may happen. If for some reason the connection to the remote unit is not detected, or if the remote’s batteries are low, you may receive a continuous Scanning for Remote message, rather than a very short one. In this case the Autotest will not be run until a properly charged remote unit is detected. Or, if a calibration message appears on the control unit’s screen, perform the calibration procedure presented in Lab 16. TIP
88
Figure 6-30: Autotest PASS and HEADROOM Report Screen
89
Figure 6-31: Autotest Test Results Screen
90
Figure 6-32: Wire Map Test Results Screen
91
All four pairs of wires are displayed, with the various conditions of each wire depicted. Notice that for UTP cable, the shield wire is displayed as an open. If there are no problems detected, the display will appear as shown in Figure 4-32. TIP
92
If the cable under test is shown to have some type of problem, you should describe the problem as accurately as possible on your work sheet, and then continue checking the rest of the test results. Once you have finished checking the test results, ask your instructor about correcting any problems that were discovered with the current cable under test. TIP
93
Figure 6-33: Resistance Test Results Screen
94
A typical reading should be far below the 40-ohm limit. The values shown (around 0.5 ohms per pair) are fine for fairly short cable runs. Long runs will show readings above those values, but should still remain below the limit. TIP
95
Figure 6-34: Length Test Results Screen
96
The length is displayed according to the units you selected during the setup procedure. For longer lengths, a slight difference would be normal between the various pairs. A typical display for length is shown in Figure 4-34. If a measured length exceeds the limit, a warning is displayed. TIP
97
Figure 6-35: Propagation Delay Test Results Screen
98
The delay time (in nanoseconds) is given for each individual pair. In cases where a propagation delay is detected, the display includes the longest delay time detected of all four pairs. TIP
99
Figure 6-36: Delay Skew Test Results Screen
100
An important electrical characteristic of cables with regard to high-speed computer network performance is delay skew. This characteristic involves the movement of electrical signals traveling down a length of a multipair CAT5 cable, and arriving at the far end of the cable at different times, depending upon which twisted pair the signals used. The difference in time taken by these electrical signals between the fastest and slowest wire pairs is the measurement called the delay skew. If a computer system’s operation is dependent on simultaneous arrival of these signals, problems will arise at some point. TIP
101
Figure 6-37: Impedance Test Results Screen
102
The characteristic impedance test will require the testing of a cable of at least 16 feet (5 meters) in length. A shorter length than this will automatically pass the test. If the cable under test exceeds the impedance limit specified by the test, the Result column will display the FAIL message. Any pair meeting the specified limit will be given a PASS result. TIP
103
Figure 6-38: NEXT Test Results Screen
104
This test is concerned with the levels of crosstalk that exist between the various wire pairs on the cable being checked. The measurement itself is expressed as the amplitude difference between the test signal and the signal being detected on another pair. The first wire pair listed is the pair into which the test signal is being injected, while the second wire pair listed is the pair from which the crosstalk is being measured. The measurement takes place at the end of the cable attached to the control unit. TIP
105
Figure 6-39: Detailed NEXT Test Results Screen
106
The specific parameters reported for the selected pair include: TIP Pairs – The specific pairs for which the displayed data is relevant. Result – The final determination as to whether the tested wire pairs meet the NEXT requirements for the selected test standard. If the result shown is PASS, then the NEXT between the tested pairs is higher than the standard specifications. A result that reports a FAIL indicates that the NEXT is lower than the standard.
107
The specific parameters reported for the selected pair include: (continued) TIP NEXT – The NEXT value that is considered to be the worst-case measurement, or the value nearest to failure. If the value displayed does fall below the specification, it will be the one that is the farthest below. Frequency – The frequency at which the worst-case NEXT value is measured. Limit – For the worst-case frequency, the lowest acceptable NEXT value.
108
The specific parameters reported for the selected pair include: (continued) TIP Margin – The difference between the limit and the measured NEXT value. If the measured NEXT value is higher than the limit, the number will be positive. If the measured NEXT is lower than the limit, the number will be negative.
109
Recall that the NEXT @ REMOTE measurements are taken from the far end of the cable, and are sent to the control unit by the remote. TIP
110
These test results are similar to the NEXT data except that the measurements are taken from the remote cable end. TIP
111
Figure 6-40: Attenuation Test Results Screen
112
The screen shown in Figure 4-40 provides a basic PASS or FAIL report for each pair. The test for attenuation is concerned primarily with how much signal strength is lost over the length of the cable. It is important to use the correct conduit or temperature settings for this measurement in order to avoid getting erroneous results. These settings were initially considered in Lab 17. If they need to be changed, they can be reached from the SETUP menu. TIP
113
Figure 6-41: Detailed Attenuation Test Results Screen
114
The specific parameters reported for the selected pair include: TIP Pairs – The specific pairs for which the displayed data is relevant. Result – The final determination as to whether the tested wire pairs meet the Attenuation requirements for the selected test standard. If the result shown is PASS, then the attenuation for the tested pairs is lower than the standard specifications. A result that reports a FAIL indicates that the attenuation is higher than the standard.
115
The specific parameters reported for the selected pair include: (continued) TIP Attenuation (dB) – The attenuation value considered to be the worst-case percent margin, at its occurring frequency. Frequency – The frequency at which the worst-case percent margin occurred. Limit – For the worst-case frequency, the highest acceptable attenuation value.
116
The specific parameters reported for the selected pair include: (continued) TIP Margin – The difference between the limit and the worst-case attenuation. If the measured attenuation value is lower than the limit, the number will be positive. If the measured attenuation is higher than the limit, the number will be negative.
117
Figure 6-42: ACR Test Results Screen
118
The screen shown in Figure 4-42 provides a basic PASS or FAIL report for each pair. The Attenuation-to-Crosstalk Ratio (ACR) is the difference between the measured values of NEXT, and the measured values of attenuation, for each wire pair combination. Obviously, the NEXT and attenuation values (in dBs) must already have been obtained before this parameter can be calculated. TIP
119
Figure 6-43: Detailed ACR Test Results Screen
120
The specific parameters reported for the selected pair include: TIP Pairs – The specific wire pairs from which the crosstalk values used to calculate the ACR were taken. Atten. Pair – The wire pair from which the attenuation values used to calculate the ACR were taken.
121
The specific parameters reported for the selected pair include: (continued) TIP Result – The final determination as to whether the tested wire pairs meet the ACR requirements for the selected test standard. If the result shown is PASS, then the ACR for the tested pairs is higher than the standard specifications. A result that reports a FAIL indicates that the attenuation is lower than the standard.
122
The specific parameters reported for the selected pair include: (continued) TIP ACR (dB) – The ACR value considered to be the worst-case, or closest to exceeding the specifications. If the ACR does exceed specifications, the displayed value is the one that exceeds the specs by the greatest amount. Frequency – The frequency at which the worst-case ACR was calculated.
123
The specific parameters reported for the selected pair include: (continued) TIP Limit – For the worst-case frequency, the highest acceptable ACR value. The selected test standard defines the limit. Margin – The difference between the limit and the worst-case ACR. If the worst-case ACR is higher than the limit, the number will be positive. If the worst-case ACR is lower than the limit, the number will be negative.
124
The control unit can store up to 500 AUTOTEST results. If the results are to be saved, this must be done prior to another AUTOTEST or SINGLE TEST being performed. TIP
125
Figure 6-44: Saving AUTOTEST Results Screen
126
If necessary, read the users manual section entitled “Saving Autotest Results.” Using a number for the ending character(s) for the cable identification name allows the Level II tester to automatically increment the name, provided that the auto increment function has been enabled. This is useful for testing a series of identical cables. TIP
127
Two conditions may exist that will require some additional steps at this point. One of these is the situation where saving the AUTOTEST results fills the last remaining memory location in the Level II tester. This will cause a warning message to be displayed, indicating that the memory is full. The other condition is when the Level II tester’s memory is already full. In this situation, any attempt to save additional test results will cause a message to be displayed indicating that additional data cannot be saved. At this point, previously saved test reports must first be deleted to make room for any new ones. Instructions for doing so can be found in the users manual. TIP
128
The only difference here is that the cable under test will be wired for the TIA T568B configuration. The wire map should still indicate wire-to-wire continuity. TIP
129
The idea here is to examine the wiring condition of the cable you created in Lab 6. Because the other two cables are known to be good, any problems that occur should be traced to the cable under test. TIP
130
Figure 6-45: Autotest Wiring Diagram for T568A Plug Terminations
131
The idea here is to examine the wiring condition of the cable you created in Lab 7. Because the other two cables are known to be good, any problems that occur should be traced to the cable under test. See Figure 4-46, if necessary, and take special note of the wire map test. TIP
132
Figure 6-46: Autotest Wiring Diagram for T568B Plug Terminations
133
The idea here is to examine the wiring condition of the cable you created in Lab 13. Because the cable you connected to its jack end is known to be good, any problems that occur should be traced to the cable under test. TIP
134
Figure 6-47: Autotest Wiring Diagram for Jack/Wall Plate Terminations
135
Consider the RJ45/T568A modular plug to be the far end of the cable. TIP
136
The idea here is to examine the wiring condition of the cable you created in Lab 14. Because the cable you connected to its jack end is known to be good, any problems that occur should be traced to the cable under test. TIP
137
Figure 6-48: Autotest Wiring Diagram for Jack/Edge-Connector Terminations
138
Consider the RJ45/T568A modular plug to be the far end of the cable. TIP
139
The idea here is to examine the wiring condition of the cable you created in Lab 9. Because this cable has already passed the preliminary continuity checks, any problems that occur will be related to other cable parameters. TIP
140
Figure 6-49: Autotest Wiring Diagram for RG58 Network
141
Figure 4-49 displays a networked configuration connected to the Level II tester, consisting of several computers cabled together (with a terminator attached to the end node). Keep in mind that the cables could be routed through a patch panel, wall plate, or various wiring closets. TIP
142
Figure 6-50: Single Section Coax Testing Diagram
143
Figure 6-51: IEEE 10Base2 Test Standard and RG 58 Cable Type
144
Figure 6-52: Screen Before IEEE 10Base2 RG 58 Autotest
145
Never change the settings on the tester to allow a test to pass that would fail at the correct settings. TIP
146
Figure 6-53: Autotest Results for IEEE 10Base2 RG 58
147
Notice that the Resistance test shows a PASS result. If it showed a FAIL result, this would be interpreted as an open circuit. This is because the terminator was removed from the far end of the cable(s) under test. TIP
148
Keep in mind that when a cable installation is being made for a customer, it’s important to make a second copy of the documentation to leave at the premises. TIP
149
The NO REFLECTION report for the Length parameter indicates a correct terminating resistance. With no signal reflections, the Level II tester cannot measure the cable’s length. TIP
150
The idea here is to examine the wiring condition of the cable you created in Lab 11. Because this cable has already passed the preliminary continuity checks, any problems that occur will be related to other cable parameters. TIP
151
Figure 6-54: Single Section RG 8 Coax Testing Diagram
152
Notice that this diagram is similar to Figure 4-46, except that the N connectors have been outfitted with the RG8 to BNC adapters for use with the control unit and the terminator. TIP
153
Figure 6-55: IEEE 10Base5 Test Standard and RG8 Cable Type
154
Figure 6-56: Screen Before IEEE 10Base5 RG8 Autotest
155
To do this, first connect the RG8 cable to the N side of one of the RG8 to BNC adapters. Then, connect the BNC side of the adapter to the Level II tester. TIP
156
Figure 6-57: Autotest Results for IEEE 10Base5 RG8
157
Notice that the Resistance test shows a FAIL result, and is interpreted as an open circuit. This is because the terminator was removed from the far end of the cable(s) under test. TIP
158
Keep in mind that when a cable installation is being made for a customer, it’s important to make a second copy of the documentation to leave at the premises. TIP
159
The NO REFLECTION report for the Length parameter indicates a correct terminating resistance. With no signal reflections, the Level II tester cannot measure the cable’s length. TIP
160
LAB 18 QUESTIONS From cables you made during previous lab procedures, which, if any, failed their respective test standards on the Level II testers? 1
161
LAB 18 QUESTIONS Of those tests performed during an AUTOTEST, which ones are specified by the TIA/EIA T568A or T568B standards? 2
162
LAB 18 QUESTIONS Which tests performed on twisted pairs required the use of a smart remote unit? 3
163
LAB 18 QUESTIONS On average, how long did the Level II testers take to provide the AUTOTEST results for one of the CAT5 twisted pair cables you tested? 4
164
LAB 18 QUESTIONS What other cable or connector types besides CAT5 UTP RJ45 terminations are the Level II testers capable of testing? 5
165
LAB 18 QUESTIONS What differences, if any, were evident during the various wire map tests using the CAT5 T568A and T568B cables? Explain. 6
166
Figure 6-58: Basic Link Testing
167
Figure 6-59: Channel Testing
168
REVIEW QUESTIONS What is a channel, as it applies to a horizontal cable run? 1
169
REVIEW QUESTIONS How is a basic link different from a channel? 2
170
REVIEW QUESTIONS Why should network cabling be tested to a standard before the network equipment is connected to it? 3
171
REVIEW QUESTIONS What is the maximum horizontal cable length for a basic link? 4
172
REVIEW QUESTIONS How are Level I and Level II cable testers different? 5
173
REVIEW QUESTIONS State the maximum length of patch cords that can be used when testing a basic link. 6
174
REVIEW QUESTIONS If equipment is repositioned after a certification test has been performed, what action must be taken? 7
175
REVIEW QUESTIONS What is NEXT? 8
176
REVIEW QUESTIONS What action is required if a run passes a test with the minimum acceptable values? 9
177
REVIEW QUESTIONS How would wrapping a cable around a 3-inch pipe affect its NEXT performance rating? 10