1

2 PIGGYBACK IMPLANTATION OF FOR HIGH HYPEROPIA 24 MONTHS FOLLOW UP JL. FEBBRARO I.VIELPEAU, F. KRIFA, S.BERBACHE, S. GANEM Department of Ophthalmology S. GANEM M.D. Rothschild Foundation - Institut de la myopie Paris - France

3 INTRODUCTION GAYTON 1993: First piggyback implantation in cataract surgery to obtain emmetropia in extremely short eyes.

4 PATIENTS and methods Retrospective study 30 eyes, 20 patients Mean age : 70 years (range : 8 – 90 Y) Sexe : 16 women, 4 men Mean follow-up : 18 M (range : 6 to 30 M)

5 Patients and METHODS CCI: 3.5 mm / Limbal: 6 mm Phacoemulsification 2 PCI in the bag : - Silicone : 13 (SI 40) - Acrylic hydrophilic : 9 (Stabibag, Quattro) hydrophobic : 6 (AR40) - PMMA : 2 (CP60)

6 Patients and METHODS Axial length : - Mean : 20.97 mm - Min : 19.75 mm - Max : 22.16 mm

7 Patients and METHODS IOL calculation formula: Combined Holladay / SRK/T

8 Patients and METHODS Total IOL emmetropic power : + 26 D to + 32 D 0 5 10 15 20 25 30 35 1471013161922252831 Eyes Diopters

9 IOLs power distribution: Equally distributed between anterior and posterior IOLs Patients and METHODS

10 SE postop Eyes RESULTS: SE Postop Mean SE : -0,50 D ; Range : -2.25 to +1.50 D

11 RESULTS: Distance UCVA 400 100 50 30 25 20 14710131619222528 VA Eyes Mean VA: 20/50; Range: 20/200 to 20/25+

12 RESULTS: Distance BCVA 400 100 50 30 25 20 14710131619222528 Eyes VA Mean VA: 20/30+ Range: 20/100 to 20/20

13 RESULTS: Near UCVA 0 1 2 3 4 5 6 7 8 1357911131517192123252729 Parinaud (P) Eyes Mean VA: P 4.3; Range: P 8 to P 2

14 RESULTS: Near BCVA 0 1 2 3 4 5 1357911131517192123252729 Eyes Parinaud (P) Mean VA: P 2.5; Range: P 5 to P 2

15 RESULTS : Near BCVA with distance correction VA mean :P 3.7 ; min : P 8 ; max : P 2

16 RESULTS: Near VA Pseudoaccomodation ? 0 1 2 3 4 5 6 7 8 Near UCVANear BCVA With distance correction Near BCVA With near correction

17 RESULTS: Complications Decentration : 1 case at 3 months PO

18 RESULTS: Complications Decentrement : 1 case at 3 months post op Hyperopic shift : 3 cases

19 RESULTS: Complications Decentrement : 1 case at 3 months Hyperopic shift : 3 cases PCO : - at 3 months : 3 cases without LBCVA - at 1 year : 4 cases (2 YAG) - at 2 years : 6 cases (4 YAG)

20 RESULTS : Complications Decentrement : 1 case à 3 months Hyperopic shift : 3 cases PCO : - at 3 months : 3 cases without LBCVA - at 1 year : 4 cases (2 YAG) - at 2 years : 6 cases (4 YAG) Pigment deposit between IOLs : 1 case at 8 months with 3 lines of loss BCVA (20/40)

21 RESULTS : Complications Decentration : 1 case at 3 months PO Hyperopic shift : 3 cases PCO : - at 3 months : 3 cases without LBCVA - at 1 year : 4 cases (2 YAG) - at 2 years : 6 cases (4 YAG) Pigment between IOLs : 1 case at 8 months with 3 lines of LBCVA (20/40) Interface opacification : 0 case

22 DISCUSSION Advantages of Piggyback : - Less spherical aberrations - Pseudoaccomodation - Wound size Ref : Gayton JL: J Cataract Refract Surg 1993 ; 19 : 776-777

23 DISCUSSION Inconvenients of Piggyback : - Interface opacification - Hyperopic shift - Surgical technique - Cost Ref : Shugar JK. J Cataract Refract Surg 1999 ; 25 : 863-867

24 DISCUSSION Which is the most appropriate IOL calculation formula? HOLLADAY, HOFFER Q, SRKT >>> SRKI & SRKII Ref : Shugar J, Lewis C, Lee A: J.cataract refract surg 1996 ; 22 : 1368-1372 Holladay JT, Gills JP, Leidlein J: Ophtalmology 1996 ; 103 : 1118-1123

25 DISCUSSION Which is the best type of IOL ? Silicone, acrylic hydrophilic or hydrophobic, PMMA ? Key points : - Biocompatibility (interface opacification) - Resistance to secondary deformation

26 DISCUSSION Prevention of interface opacification: - Large CCC - Meticulous I/A - Implantation bag/sulcus - IOL (acrylic hydrophilic/phobic) - Haptics perpendicular Ref : Masket S JCRS April 1998

27 CONCLUSION Seducing technique in extremely short eyes: IOL power > 29 D Secondary indications: Pseudophakic eyes with refractive errors