MDS Monitoring Software
2
Page 2 Contents Introduction User Interface Service Personnel Interface System Requirement Demonstration
3
Page 3 Introduction
4
Page 4 Introduction Smart Commander Human to MDS system interface - 32 Outdoors - 48 indoors per indoors - Total1536 indoors Monitor and control the MDS system both indoors and outdoors User and Service Personnel Interface
5
Page 5 Smart Commander Layout Gateway Computer Indoor units Outdoor units Centralize Control RS485 RS232 Introduction
6
Page 6 User Interface
7
Page 7 User Interface Indoor Monitoring and Control Interface
8
Page 8 User Interface System Monitoring and Control Interface
9
Page 9 Type of Control Features Single Control : Select a indoor unit only Multiple Control : Select many indoor units Group Control : All the indoor units in the system
10
Page 10 Area of Control ON/OFF Temperature Setting Click “ ” or “ ”, can adjust the set temperature Select “ ” or “ ”, can turn on or close the units Features
11
Page 11 Area of Control (…continue…) Operating Model (Cool, Heat, Dry or Fan) Air Swing (Not applicable for MCC model) Fan Speed Sleep Mode Handset Lock Function Select fan speed: (must select) Select mode (must select) Select assistant functions: Features
12
Page 12 Icon for indoor/outdoor unit Basic control in “Indoor Monitor” page Features
13
Page 13 Group Setting with 7 days programmable timer Features
14
Page 14 Customize grouping with 7 days programmable timer Features
15
Page 15 Error Code Features
16
Page 16 Service Personnel Interface
17
Page 17 Service Personnel Interface
18
Page 18 Single, Master, Slave Cooling, Heating, Defrost, Stop Display OD program OD output capacity (Include Slave) T sh_out : OD superheat Digital compressor output % OD Fan: Stop, Low, High HS: High Pressure (bar) LS: Low Pressure (bar) Heating electronic expansion valve Subcool electronic expansion valve Bypass way vale 4-way valve (Heatpump model) Available Data - OD
19
Page 19 TH1: Discharge air temp TH2: The 1 st condenser entering temp TH3: The 1 st condenser middle temp TH4: The 2 nd condenser entering temp TH5: The 2 nd condenser middle temp TH6: Entering water temp TH7: Heating water temp TH8: Outdoor temp TH9: Temp before subcool TH10: Temp after subcool TH11: Subcool loop exit temp TH12: Suction temp Sensor is unavailable Available Data - OD
20
Page 20 Outdoor Address Red Line: Heating Green Line: Cooling / Dry Black Line: Stop Sensor location Refrigerant Diagram & Sensor Location Outdoor Model
21
Page 21 Indoor address Indoor Control and Sensor Reading Indoor Data: Type of indoor and model Tr: Return Air Temperature To: Coil Outlet Temperature Tm: Coil Middle Temperature Ti: Coil Inlet Temperature Ts: Set Temperature EXV: Indoor EXV Opening
22
Page 22 Click “Up” or “Down”, ID address number will move up or down Click “Back Page” or “Next Page”, the page will turn up or down Indoor Control and Sensor Reading
23
Page 23 Click “Ctrl” to change indoor setting Choose optional parameters to control single unitChoose optional parameters to control single unit Optional mode: Stop, Cooling, Heating, Dry, FanOptional mode: Stop, Cooling, Heating, Dry, Fan Fan Speed: Low, Medium, High & AutoFan Speed: Low, Medium, High & Auto Assistant function: Aux heater, Swing & LockAssistant function: Aux heater, Swing & Lock Indoor Control and Sensor Reading
24
Page 24 System Requirement
25
Page 25 System Requirements CPU : 800MHz and above Memory : 256MB RAM or Higher Hard Drive : 4G or higher for hard disk space OS : Windows 2000/XP Resolution : 1024 x 768 Monitor : Larger than 15 inch, & 17 inch is recommended Serial port & USB port available
26
Page 26 Demonstration
27
Page 27 The End