Presentation is loading. Please wait.

Presentation is loading. Please wait.

Excavator X62 Installation. This Webinar is LISTEN only Questions will be answered in writing at the end of the Webinar. QUESTIONS?

Similar presentations


Presentation on theme: "Excavator X62 Installation. This Webinar is LISTEN only Questions will be answered in writing at the end of the Webinar. QUESTIONS?"— Presentation transcript:

1 Excavator X62 Installation

2 This Webinar is LISTEN only Questions will be answered in writing at the end of the Webinar. QUESTIONS?

3 Excavator X62 Installation Webinar September 18 th, 2009 LS-B10W Laser Receiver Installation LS-B10W Verification TS-1 Sensors Installation/Calibration 9-4-09 Webinar Verification 9-11-09 Webinar

4 Reference Material 7010-08107010-0814

5 LS-B10W Mounting Where to mount the LS-B10W  Position the stick appropriately LS-B10W vertical  Determine LS-B10W Location Where on Stick to prevent damage

6 LS-B10W Mounting Bracket

7 LS-B10W Connection

8 Body Measurements

9  Graphical display only Boom Pivot Height

10 Laser Receiver Measurements Calibrate

11 From Bucket Pivot Calibrate

12 Left of Pivot Line Calibrate

13 Depth to center of stick Calibrate

14 Depth to center of stick Calibrate

15 LS-B10W Laser Receiver Calibration  TS-1 Calibrated  0.0 o House roll  Position LS-B10W vertical  Press Calibrate

16 LS-B10W Verification  Level String  6’ below laser 6’ Below

17 LS-B10W Verification  Zero to Laser (laser on detector)  Elevation set point -6’  Verify bucket on string  Move machine and repeat

18 Wedge Error Wedge errors or Inconsistent elevation errors:  Perform Elevation Accuracy Verification to check machine and sensor calibration TS-1 Sensor Calibration Implement length

19 Depth to Center of Stick Depth to center of stick:  An error in this measurement would create an elevation error when the body of the machine is on a side slope. Calibrate

20 Left of Pivot Line Left of pivot line:  An error in this measurement would create an elevation error when the stick is referenced at any angle other than vertical. Calibrate

21 From Bucket Pivot From bucket pivot  An error in this measurement would create an elevation error when the stick was in any position other that horizontal. Calibrate

22 LS-B10W Angle Calibration LS-B10W angle calibration:  An error with this calibration would create and elevation error depending on the angle of the sensor when referencing the laser and the distance the laser is away from on- grade.

23 Address to download all TU-Live Webinars: ftp://TUlive+topconuniversity.com:tulive@ftp.topconuniversity.com/ ftp://TUlive+topconuniversity.com:tulive@ftp.topconuniversity.com/ –Recorded Webinar –PP Presentation –Webinar Q & A Additional requests for TU staff: Email: training@topcon.comtraining@topcon.com Questions?


Download ppt "Excavator X62 Installation. This Webinar is LISTEN only Questions will be answered in writing at the end of the Webinar. QUESTIONS?"

Similar presentations


Ads by Google