May 12th. 2011| 1| 1 New On Stack Emission Monitoring Technology www.greeninstruments.comwww.greeninstruments.com www.danfoss.com/ixawww.danfoss.com
2
May 12th. 2011| 2| 2 Content Emission Monitoring – why? Monitoring Technologies Experience Gained Emission Monitoring - System Requirements Technology respons Future Of Emission Monitoring
3
May 12th. 2011| 3| 3 Emission Monitoring – why? Main drivers: Energy optimisation Environmental soundness Meeting regulations CO2 NO - NO2 - PM CO - H2O – SO2 Shipping is the primary mode of transportation NOx, SOx and PM from shipping is a significant portion of global emission Human health & crops are seriously affected by NOx, SOx and PM To reduce, control and manage NOx, SOx and PM emission various technologies will be implemented in the coming years. Thus emission monitoring will be part of the solution
4
May 12th. 2011| 4| 4 Monitoring Technologies – Schematic Gas sampling at stack Initial gas conditioning Transport (sampling line) Mulitplexing (several lines) Final gas conditioning Gas analysis Visualization & Reporting
5
May 12th. 2011| 5| 5 Monitoring Technologies – Sampling Extractive CEM Systems Cold extractive Hot extractive Dilution systems In-situ CEM systems Cross stack light based systems Probe and point based systems Gas sampling at stack Initial gas conditioning Transport (sampling line)
6
May 12th. 2011| 6| 6 Monitoring Technologies – Analyzing Methods Chemiluminescece (CLD) UV fluorescence Non Dispersive Infra Red (NDIR) Electrochemical cells Lased Detection (TLD & QCL) Zirconium oxide sensors (ZrO2) Mulitplexing (several lines) Final gas conditioning Gas analysis
7
May 12th. 2011| 7| 7 Experience gained CLD Probe Pre-conditioning Probe Dilution with dry air Transport Sample line Converting NO2 to NO Analyzing O3 Sample gas After treetment Visualization & ReportingAlarm monitoring Proven technology (reference method) Require sample & conditioning systems Slow response time Can only measure NO not NOx High consumable & maintenance requirements A/C unit will normally be required Total high cost of ownership
8
May 12th. 2011| 8| 8 Experience gained ZrO2 Probe Pre-conditioning Probe Sample/back-flushing Analyzing Visualization & Reporting Alarm monitoring Well-proven – cost effective technology developed for the automotive industry. Real-time measurement with no delays from sample lines, multiplexing, coolers and converters Easy installation, operation and maintenance Total low cost of ownership Measure only NOx and O2, no other gases Sensor degradation by SO2
9
May 12th. 2011| 9| 9 Emission Monitoring – System Requirements Robust online measurement Simple - No conditioning or gas transport Direct - Accurate Hot gas Measurement Adaptable to increasing regulation Low maintenance Low cost of ownership Certified to MARPOL annex Vl
10
May 12th. 2011| 10 Patented IR Principle Correlated suspect/reference Superior ambient & source artifact immunity – pressure, temperature… Robust measurement Patented & Patents Pending
11
May 12th. 2011| 11 Thermally de-coupling the optical sensor Patented concept of thermally de-coupling optical path sight-tubes Effective thermal de-coupling enables hi-temp measurement Wide-band IR transmission Gas filled for undisturbed transmission De-focused optical system mitigating spot contamination on optics Patented & Patents Pending
12
May 12th. 2011| 12 Patented Gas Flow Chamber Vortex-flow chamber for undisturbed optical gas measurement Structured gas flow for avoidance of residuals in optical path Intrinsic cleaning effect on sight-glasses Particles held away from optical path center-line Patented & Patents Pending
13
May 12th. 2011| 13 Patented optical path protection IR transmissive nano-coated sight-glasses Contaminant repellent Super hydrophobic Heat & Corrosion resistant Patented & Patents Pending
14
May 12th. 2011| 14 Combustion Emission Sensor System Modular sensor system Direct and continuous measurement Hot/Wet combustion gasses Configurable for exact gas measurement needs All core technologies patented Patented & Patents Pending
15
May 12th. 2011| 15 Future of emissions monitoring The world depends on shipping, but emissions must be reduced Global and local regulation will reduce emission Multiple emissions mitigation technologies will be implemented The operation of emissions mitigation systems should be optimized The effect should be documented Online emissions monitoring is part of efficient shipping
16
May 12th. 2011| 16 Thank you for your attention Poul K. Sørensen, Green Instruments A/S pks@greeninstruments.com Henrik G. Moos, Danfoss IXA A/S hgm@danfoss.com