1
TAU status 14/2/2012
2
Temperature behavior in red Delayed response No A/C T=24-25 C 19 o C Cold A/C T=19-20 C 30 o C Hot A/C T=28-32 C 16:30 18:00 04:00 02:00 CH 7 Panel setup: Ni-Ni panel CF4 600Torr 6High Voltage lines 10 Read-Out lines, with attenuators. 1830 V # hits/ 30 mins Sec PDP hits /channel
3
Temperature behavior Panel setup: Ni-SnO 2 panel MDT gas: Ar-Co 2 600Torr 6High Voltage lines 10 Read-Out lines, with attenuators. 980 V Source with collimator above RO lines 2,3,4 Some problematic channels, not electronics issue. Could be due to bad connections in the RO card ? However, these are less relevant to the measurement PDP hits /channel
4
Temperature behavior 13:00 reach stable temp The drop in rate starts at ~13:00. (black line ) Each red line is 24 hours. Start at 10:30 am No response to changes in temperature after the first increase in temperature. CH2 Usual behavior # hits/ 30 mins Sec PDP hits /channel hours Temp 19 o C Cold A/C T=19-20 C 30 o C Hot A/C T=28-32 C
5
Temperature Control Problem with Temperature control. Two A/C. The left rise A/C #1 – located in the other side of the room relative to the temp sensor - but stopped working. The right drop A/C #2 - close to the Temperature sensor – not a reliable measurement. More “scientific “ method is needed to control the temperature. In order to perform more accurate measurements. In any case strange behavior of the detector. Rate declines with time. 12/2/12 Mid-day 9/2/12 12/2/12 Mid-day
6
The hypothesis Paschen's curve Temp decrease, so does the pressure. Breaking Voltage is lowered, so with the same HV and lower temperature we expect to have higher rate.
7
Test Beam preparations Online monitoring Server-client output. Multi-threaded readout: – for plotting histograms quickly. – receive PDP output. Individual CH selection A few simple drawing options