INSTALLING NAECA III PRODUCT IN CONFINED LOCATIONS Brought to you by: NAECA III
2
What is NAECA III ? The National Appliance Energy Conservation Act of 1987 is a United States Act of Congress that regulates energy consumption of household appliances. These laws and regulations have to do with creating mandatory standards that deal with the energy efficiency. These standards were put in place to ensure that manufacturers were building products that are at the maximum energy efficiency. Since these standards have gone into effect they have positively affected both the American economy and the environment. Americans who have purchased these appliances have been saving money on their electricity bills every year. It is estimated that these savings have been greater than $300 billion. WHAT IS NAECA III
3
INSTALLING NAECA III GAS PRODUCT Gallon Capacity Pre-NAECA IIINAECA III Gas 300.610.63 400.590.62 500.580.60 550.580.59 600.560.75 660.540.75 750.530.74 800.520.74 1000.480.72 NAECA III GAS EF REQUIREMENTS *Commercial water heaters are not affected*
4
INSTALLING NAECA III GAS PRODUCT Pre-NAECA NAECA III Option 1 NAECA III Option 2 +
5
INSTALLING NAECA III GAS PRODUCT Gallon Capacity Pre-NAECA III Model Height (Inches) Diameter (Inches) NAECA-III Model Height (Inches) Diameter (Inches) 3030 G 1”61 1/21630 G 2”61 3/418 30New 30 gal 1” foam with blanket*30 G 1”+61 3/416 3030 G 2”61 1/21830 G 2”61 3/418 40 New 40 gal under 40k Btu input40 G 2”6220 4040 G 1”61 3/41840 G 2”6220 40New 40 gal 1” foam with blanket*40 G 1”+6218 4040 G 2”61 3/42040 G 2”6220 5050 G 1”60 3/42050 G 1 ½”60 3/421 5050 G 2”612250 G 2”60 3/422 Tall Gas Models
6
INSTALLING NAECA III GAS PRODUCT Gallon Capacity Pre-NAECA Model Height (Inches) Diameter (Inches) NAECA-III Model Height (Inches) Diameter (Inches) 3030 G 1”501830 G 2”5020 30New 30 gal 1” foam with blanket*30 G 1”+5018 4040 G 1”51 1/22040 G 2”51 1/222 40 New 40 gal 1” foam with blanket*40 G 1”+51 1/220 4040 G 2”51 1/22240 G 2”51 1/222 5050 G 2”53 1/42450 G 2”5324 Short Gas Models
7
INSTALLING NAECA III GAS PRODUCT Gas Replacement Options Original 40G 1” 62” Tall 18” Dia New 40 G 2” 62” Tall 20” Dia New 40 1” + Blk 62” Tall 18”* Dia 1” Foam insulation 2” Foam insulation 1” Foam insulation + *External Blanket Option 1 Option 2
8
INSTALLING NAECA III GAS PRODUCT Product Improvements Minimum inlet gas pressure reduction Manifold pressure change from 5”wc to 4”wc 5”WC 4”WC Ported ball type drain valve 30% more flow for faster draining True ¼ turn w/stop
9
INSTALLING NAECA III ELECTRIC PRODUCT Gallons Pre- NAECA NAECA III Electric 300.930.95 400.920.95 500.900.95 550.900.94 660.881.98 800.861.97 1200.811.92 Volume based calculation with new criteria established for larger storage capacity models – over 55 gallons – Increase for ≤ 55 gal capacities a challenge for units already very efficient – Increase for > 55 gal levels substantial, requiring technology change to heat pump water heaters NAECA III Requirements
10
Gallon Capacity Pre-NAECA Model Pre-NAECA Height Pre-NAECA Diameter NAECA III ModelHeightDiameter 3030 Tall46-1/21830 Tall46-1/219 4040 Tall59-1/21840 Tall60-1/420 5050 Tall542050 Tall60-1/222 5050 Tall Blkt*60-1/421 5555 Tall60-1/420Discontinued – See 50 Tall 5555 Tall56-1/224 6666 Tall60-1/420-1/2Discontinued – See Heat Pump 8080 Tall60-1/222-1/2Discontinued – See Heat Pump 119120 Tall64-1/428Discontinued – See Heat Pump Tall Electric Models INSTALLING NAECA III ELECTRIC PRODUCT
11
Gallon CapacityPre-NAECA Height (Inches) Diameter (Inches)NAECA-III Model Height (Inches) Diameter (Inches) 3030 Short/Reg36-1/220-1/230 Short/Reg39-3/422 30 30 Short/Reg Blkt * 3920 4040 Short/Reg4420-1/240 Short/Reg5022 5050 Short/Reg482250 Short/Reg49-3/424 Short Electric Models INSTALLING NAECA III ELECTRIC PRODUCT
12
LOWBOY TOP CONNECT Gallon CapacityPre-NAECA Height (Inches) Diameter (Inches)NAECA-III Model Gallon Capacity Height (Inches)Diameter (Inches) 3030 Low302230 Low2831-1/424 3030 Low Blkt*302030 Low Blkt*283022 3840 Low31-1/42340 Low3831-3/426 3840 Low Blkt*32-1/42440 Low Blkt*3831-3/424 5050 Low3426-1/2Discontinued LOWBOY SIDE CONNECT Gallon CapacityPre-NAECA Height (Inches) Diameter (Inches)NAECA-III Model Gallon Capacity Height (Inches)Diameter (Inches) 3030 Low302230 Low2831-1/424 30 30 Low Blkt*283022 3840 Low30-1/22340 Low3831-3/426 38 40 Low Blkt*3831-3/424 Low Boy Electric Models
13
INSTALLING NAECA III ELECTRIC PRODUCT Mixing Valves
14
INSTALLING NAECA III ELECTRIC PRODUCT Mixing Valves PART#: 400559
15
INSTALLING NAECA III ELECTRIC PRODUCT Original 50 Tall 54” Tall 20” Dia New 50 Tall 60.5” Tall 22” Dia New 50 Tall Blkt* 60.25” Tall 21” Dia* New 40 Tall 60 1/2” Tall 20” Dia Option 1 Option 2 Option 3 1.75” Foam insulation 3” Foam insulation 2.5” Foam insulation + *External Blanket 40 Gallon Tank + Mixing Valve Electric Replacement Options
16
INSTALLING NAECA III ELECTRIC PRODUCT Standard 6/6 & 10/6 – Copper upper element 4.5KW 240V – Incoloy lower element 4.5KW 240V Premium 10/10 – Dual Incoloy elements 5.5KW 240V – Electronic thermostat replaces electromechanical Electric Element Changes
17
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 720193
18
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 500738
19
INSTALLING NAECA III ELECTRIC PRODUCT Gas Installation Electric Installation
20
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 207907
21
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 207905
22
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 544054
23
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 727280
24
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 720184
25
INSTALLING NAECA III ELECTRIC PRODUCT PART#: 109952
26
Thank You !!! Brought to you by: NAECA III