Download presentation
Published byIrea McCracken Modified over 10 years ago
1
PBA Repair Guide [SGH-I900] Samsung Electronics
2
Contents 1. PBA Diagram 2. Trouble Shooting 2-1. No Power
2-2. Lockup / Reset 2-3. SIM Card Failed 2-4. Camera Failed 2-5. No Vibration 2-6. Bluetooth Searching Failed 2-7. No Charging 3. Appendix 3-1. How to check the voltage and frequency
3
1. PBA Diagram SGH-I900 TOP Diagram Appearance
4
1. PBA Diagram SGH-I900 Bottom Diagram Appearance
5
2-1. No Power (PDA) SGH-I900 Trouble shooting
C668 = 3V C665, C674 = 1.8V C667, C677 = 2.6V Input the power (3.8V) Power-on-current >= 100mA Y Y Y U304 P1 = 4V Check UCP600 N N N Download S/W (PDA) Check U304 Check U605 ※ It’s a general case. It cannot be available on the special case.
6
2-1. No Power (PDA) SGH-I900 Input the power 3.8V
2. Check the power-on-current >= 100mA - If not : Download PDA software (refer to 2-2. Lockup/Reset) 3. Check the voltage U304 Pin number 1 = 4V - If not : Check the U304 (crack, open, short, etc) 4. Check the Voltage 1) C668 = 3V 2) C665, C674 = 1.8V 3) C667, C677 = 2.6V - If not : Check the U605 (crack, open, short, etc) 5. There is no problem from 1 to 4, check the UCP600
7
2-1. No Power (PDA) SGH-I900 Picture 2-1-3, 2-1-4, 2-1-5 UCP600 1 C677
● 1 C677 ● U605 U304 ● ● C668 ● ● C667 C674 C665
8
Voltage Div : 1V, Time Div : 1㎳
2-1. No Power (PDA) SGH-I900 Scope 2-1-3, 2-1-4 U304 Pin number 1 C668 Voltage Div : 1V, Time Div : 1㎳ 4V 3V
9
Voltage Div : 1V, Time Div : 1㎳
2-1. No Power (PDA) SGH-I900 Scope 2-1-4 C665, C674 C667, C677 Voltage Div : 1V, Time Div : 1㎳ 1.8V 1.4V
10
2-1. No Power (Phone) SGH-I900 Trouble shooting
Input the power (3.8V) Power-on-current >= 100mA Y Y Y U201 P2 = 1.8V D300 P2 = 1.8V N N N Download S/W (Phone) Check U201 Check UME201 Y Y D300 P3 = 1.8V OSC102 = 32kHz Check U301 N N Check OSC102 or UCP600 Check D300 ※ It’s a general case. It cannot be available on the special case.
11
2-1. No Power (Phone) SGH-I900 Input the power 3.8V
2. Check the power-on-current >= 100mA - If not : Download Phone software (refer to 2-2. Lockup/Reset) 3. Check the voltage 1) U201 Pin number 2 = 1.8V (Low) - If not : Check the U201 (crack, open, short, etc) 2) D300 Pin number 2 = 1.8V (Low) - If not : Check the UME201 (crack, open, short, etc) 3) D300 Pin number 3 = 1.8V (Low) - If not : Check the D300 (crack, open, short, etc)
12
2-1. No Power (Phone) SGH-I900 4. Check the OSC102 = 32kHz
- If not : Check the OSC102 or UCP600 5. If there is no problem from 1 to 4, check the U301 (crack, open, short, etc)
13
2-1. No Power (Phone) SGH-I900 Picture 2-1-3, 2-1-4, 2-1-5 UCP600 2, 3
● ● D300 UME201 OSC102 U201 ● 2
14
2-1. No Power (Phone) SGH-I900 Scope 2-1-3, 2-1-4 U201 P2, D300 P2, 3
OSC102 Voltage Div : 1V, Time Div : 1㎳ Voltage Div : 1V, Time Div : 20㎲ 32kHz 1.8V
15
2-2. Lockup / Reset SGH-I900 Trouble shooting
(Omnia screen) Use a PDA J-TAG Check UCP600 (PDA) Check UCP600 (PDA) Download the latest PDA S/W N Download Completed Y Lockup or reset (Same as declared) Y N N Download the latest Phone S/W Check UME200 (Phone) Repeat the lockup/reset test Check UCP200 (Phone) Lockup/Reset (Phone off after power on) Use a Phone J-TAG ※ It’s a general case. It cannot be available on the special case.
16
2-2. Lockup / Reset SGH-I900 Use a J-TAG to enable USB
- Lockup/Reset on Omnia screen : Use a PDA J-TAG - Phone off after power on : Use a Phone J-TG 2. Download the latest software - If download is not completed : Check the UCP600 (PDA) (crack, open, short, etc) : Check the UME200 (Phone) Picture 2-2-2 UME200 UCP600 UCP200
17
2-2. Lockup / Reset SGH-I900 - If download is completed but it still has the same defect : Check the UCP600 (PDA) (crack, open, short, etc) : Check the UCP200 (Phone) - If download is completed and you cannot find the same defect : Repeat the lockup/reset test declared originally
18
2-3. SIM Card Failed SGH-I900 Trouble shooting
Check the 6-pins of SIM socket There is durst or damaged N Input the power (3.8V) Pin 1, 2, 4 = 3V Pin 3 = 3V Clock Y N Clean or change SIM socket Check U301 or UCP200 ※ It’s a general case. It cannot be available on the special case.
19
2-3. SIM Card Failed SGH-I900 Check the 6-pins of SIM socket
- If there is a durst : Clean the pins - If it is damaged : Change the SIM socket 2. Input the power 3.8V 3. Check the voltage 1) Pin number 1, 2, 4 = 3V 2) Pin number 3 = 3V Clock - If not : Check the U301 or UCP200 (crack, open, short, etc) ※ Check the voltage when you input the power on the PBA. Picture 2-3-3 1 2 3 ● ● ● ● 4
20
Voltage Div : 1V, Time Div : 50㎳
2-3. SIM Card Failed SGH-I900 Scope 2-3-3 Pin number 1, 2, 4 Pin number 3 Voltage Div : 1V, Time Div : 50㎳ 3V Clock 1.9V Clock 3V 1.9V
21
2-4. Camera Failed SGH-I900 Trouble shooting
There is durst or damaged N Y Check HDC500 U512 P3 = 3V C535 = 1.2V Y N N Clean or Change HDC500 Check UCP600 Check U512 ※ It’s a general case. It cannot be available on the special case.
22
2-4. Camera Failed SGH-I900 Check the HDC500
- If there is a durst or damaged : Clean or change the HDC500 2. Connect a camera and input the power 3.8V 3. Check the voltage U512 Pin number 3= 3V - If not : Check the UCP600 (crack, open, short, etc) 4. Check the voltage C535 = 1.2V - If not : Check the U512 (crack, open, short, etc) ※ Check the voltage during camera entering mode. - LCD, TSP and camera must be connected to PBA. - Input the power and press key number *#0*# → 7
23
2-4. Camera Failed SGH-I900 Picture 2-4-3, 2-4-4 HDC500 UCP600 U512 3
● 3 ● C535
24
Voltage Div : 1V, Time Div : 1㎳
2-4. Camera Failed SGH-I900 Scope 2-4-3, 2-4-4 U512 Pin number 3 C535 Voltage Div : 1V, Time Div : 1㎳ 3V 1.2V
25
2-5. No Vibration SGH-I900 Trouble shooting
Connect a motor Input the power Vibration on There is durst or damaged N Check the HDC500 U510 P1 = 3V C541 = 3V Y N N Clean or Change HDC500 Check U609 Check U510 ※ It’s a general case. It cannot be available on the special case.
26
2-5. No Vibration SGH-I900 Check the HDC500
- If there is a durst or damaged : Clean or change the HDC500 2. Connect a motor, input the power (3.8V), Vibration on 3. Check the voltage U510 Pin number 1 = 3V - If not : Check the U609 (crack, open, short, etc) 4. Check the voltage C541 = 3V - Check the U510 (crack, open, short, etc) ※ Check the voltage during vibrating. - LCD, TSP and vibrator must be connected to PBA. - Input the power and press key number *#0*# → 5
27
Voltage Div : 1V, Time Div : 1㎳
2-5. No Vibration SGH-I900 Picture 2-5-1, 2-5-3, 2-5-4 Scope 2-5-3, 2-5-4 U510, U541 Voltage Div : 1V, Time Div : 1㎳ HDC500 U609 U510 3V 1 ● ● C541
28
2-6. Bluetooth Searching Failed SGH-I900
Trouble shooting Input the power Bluetooth on Search devices Check L119, ANT103 There is problem (crack, open) N U101 P6 = 3.3V U101 P5 = 1.8V Y Y N Resolder or change Check U101 Y OSC101 = 26MHz Check MOD100 N Check OSC101 ※ It’s a general case. It cannot be available on the special case.
29
2-6. Bluetooth Searching Failed SGH-I900
1. Check the L119, ANT103 (crack, open, etc) - If there is a problem : Resolder or change it 2. Input the power (3.8V), Bluetooth on, Search devices 3. Check the voltage U101 Pin number 6 = 3.3V, Pin number 5 = 1.8V - If not : Check the U101 (crack, open, short, etc) 4. Check the clock OSC101 = 26MHz - If not : Check the OSC101 (crack, open, short, etc) 5. If there is no problem from 1 to 4, check the MOD100 (crack, open, short, etc)
30
2-6. Bluetooth Searching Failed SGH-I900
※ Check the voltage during searching devices - LCD and TSP must be connected to PBA. - Insert a SIM card and input the power. - Activate on the bluetooth and search devices.
31
2-6. Bluetooth Searching Failed SGH-I900
Picture 2-6-1, 2-6-3, 2-6-4, 2-6-5 U101 ● ● 5,6 MOD100 OSC101 L119 ANT103
32
Voltage Div : 1V, Time Div : 1㎳
2-6. Bluetooth Searching Failed SGH-I900 Scope 2-6-3 U101 Pin number 6 U101 Pin number 5 Voltage Div : 1V, Time Div : 1㎳ 3.3V 1.8V
33
Voltage Div : 1V, Time Div : 20㎱
2-6. Bluetooth Searching Failed SGH-I900 Scope 2-6-4 OSC101 Voltage Div : 1V, Time Div : 20㎱ 26MHz
34
2-7. No Charging SGH-I900 Trouble shooting
Connect TA to the power supply Y Y Input the power (5V) Current = 400 ~ 600mA U303 P10 = 5V Check UCP600 N N Check U303 or IFC400 Check U301 ※ It’s a general case. It cannot be available on the special case.
35
2-7. No Charging SGH-I900 Connect TA to the power supply and input the power (5V) 2. Insert a TA to PBA 3. Check the current = 400 ~ 600mA - If not : Check the U301 (crack, open, short, etc) 4. Check the voltage U303 Pin 10 = 5V - If not : Check the U303 or IFC400 5. If there is no problem from 1 to 4, check the UCP600 (crack, open, short, etc) ※ Check the voltage during charging. - TA can be connected to power supply must be prepared. Picture 2-7-1, 2-7-2 TA Insert to PBA
36
Voltage Div : 1V, Time Div : 1㎳
2-7. No Charging SGH-I900 Picture 2-7-4, 2-7-5 Scope 2-7-4 U303 Pin number 10 Voltage Div : 1V, Time Div : 1㎳ U301 UCP600 U303 ● 10 IFC400 5V
37
3-1. How to check the voltage and frequency
Equipment : Oscilloscope (Bandwidth : more than 500MHz) PBA condition : Power on by using power supply Ground the scope Put a scope to the point you want to check Input the power Ground Put a scope
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.