Camera Remote Control Unit (AK-HRP150) Camera remote control unit AK-HRP150 is a camera controller for multi-purpose camera AK- HC900, AK-HC910 and AK-HC1500,

Similar presentations


Presentation on theme: "Camera Remote Control Unit (AK-HRP150) Camera remote control unit AK-HRP150 is a camera controller for multi-purpose camera AK- HC900, AK-HC910 and AK-HC1500,"— Presentation transcript:

1 Camera Remote Control Unit (AK-HRP150) Camera remote control unit AK-HRP150 is a camera controller for multi-purpose camera AK- HC900, AK-HC910 and AK-HC1500, and this unit can supply power and G/L signal for a camera OPERATE Switch Alarm Indicator MENU ON/OFF Switch MENU Switch SCENE FILE Switch Video Selection Switch AUTO WHITE Switch AUTO BLACK Switch R/B Gain Volume R/B Pedestal Volume ND Filter Switch CC Filter Switch Gain Switch and Gain Indicator Shutter Switch and Shutter Indicator Iris F Value or Master Pedestal Indicator Iris F Value/ Master Pedestal Switch Master Pedestal Control IRIS Control (Rotary Encoder) 1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 Tally Indicator Auto Iris Switch 17 18 19 20 1 OPERATE Switch OPERATE Switch is used for permission of operation for camera control. Light ON: When power of camera is switched on, OPERATE switch turns on a light and communication between camera and control unit starts. Light OFF: In condition of “Light ON”, OPERATE switch is switched a light off when OPERATE switch is pushed. In this condition, camera control is inhibited. 2 Alarm Indicator Alarm indicator turns to red color when a fan in the camera stopped. In normal condition, color of this alarm indicator is green. 3 MENU ON/OFF Switch [MENU ON] When MENU Switch is switched on, camera control menu appears in a main video line. 4 SCENE FILE Switch [SCENE FILE TRE,USER1,USER2] 5 MENU Switch [MENU] When MENU Switch is turned,ITEM can be selected and data can be changed. When MENU Switch is switched on, ITEM can be confirmed and data can be fixed. Scene file data which were registered in the camera can be called. 6 Video Selection Switch [CAM/BAR/TEST MODE] Camera video output can be selected by this switch. CAM Switch light on: Camera Video Output BAR Switch light on: Color Bar Output TEST Switch light on: Test Signal Output

2 Camera Remote Control Unit (AK-HRP150) AUTO WHITE Switch [AUTO WHITE] 7 AUTO WHITE Switch is used for automatic white balance. Light ON: This indicates to receive the start of automatic white balance by pushing AUTO WHITE Switch. Light ON and OFF:This alarms that white balance adjustment has not completed after automatic white balance adjustment. Light OFF: This shows that white balance adjustment has completed. AUTO BLACK Switch [AUTO BLACK] 8 AUTO BLACK Switch is used for automatic black balance. Light ON: This indicates to receive the start of automatic black balance by pushing AUTO BLACK Switch. Light ON and OFF:This alarms that black balance adjustment has not completed after automatic black balance adjustment. Light OFF: This shows that black balance adjustment has completed. R/B Gain Volume [R/B GAIN] 9 Red and blue level can be adjusted by these gain volumes. Automatic white balance adjustment can be controlled. R/B Pedestal Volume [R/B PED] 10 Red and blue pedestal can be adjusted by these pedestal volumes. Automatic black balance adjustment can be controlled. ND Filter Switch [ND FILTER] 11 This switch can be used for ND filter selection. ND-1: 100% ND-2: 25% ND-3: 6.3% ND-4: 3.2% CC Filter Switch [CC FILTER] 11 This switch can be used for CC filter selection. CC-A: 3200K CC-B: 4300K CC-C: 6300K CC-D: Cross Gain Switch and Gain Indicator [GAIN] 13 Video gain indicates as follows. 0dB 9dB 18dB 0dB 9dB 18dB Super Gain 1 Super Gain 2 Super Gain 3 Shutter Switch and Shutter Indicator [SHUTTER ON] 14 Electronic shutter speed which is selected by camera menu can be switched on and off. A light turns on when shutter function is selected. Iris F Value/Master Pedestal Switch [CHECK] 15 Indication of Iris F value or M-PED value is switched every pushing this switch. Iris F Value or Master Pedestal Indicator 16 Iris F value or master pedestal value is displayed in this indicator. Master Pedestal Control IRIS Control (Rotary Encoder) Tally Indicator Auto Iris Switch [AUTO] 17 18 19 20 Auto iris operation works by pushing this switch. Light ON: Auto Iris Condition Tally light turns on when there is a tally input in external tally connector. Master pedestal can be controlled by this controller. Master pedestal increases by rotating this controller clockwise. Master pedestal and R/G/B pedestal are independent, then R/G/B pedestals do not change when master pedestal is changed. Lens iris level can be controlled by this controller.

3 Camera Remote Control Unit (AK-HRP150) 1 2 3 Power Connector Camera I/F Connector Tally Connector 1 Camera I/F Connector (HIROSE:HDAB-15S) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Description Y OUT Pb OUT Pr OUT G/L IN DC12V IN GND TXD Y GND Pb GND P r GND G/L GND DC12V GND TX GND RXD RXD GND Direction of DATA TXD:CAM Controller RXD:Controller CAM 2 Power Connector 3 Tally Connector (HIROSE:HR10A-7R-4P) 1 3 4 Description 2 1 3 4 2 GND N.C. DC12V R TALLY R TALLY COM CONNECTORS SPECIFICATIONS 1 Control Item:Refer to control panel description. 2 Operating Temperature: 0°C~+40°C (32°F~104°F) 3 Storage Temperature:-20°C~+60°C (-4°F~140°F) 4 Weight:Approx.1.2kg (2.65lbs) 5 Dimensions:92(W)X225(H)X65(D)mm (3-5/8WX8-7/8HX2-9/16D) 6 7 8 9 10 Input Power:DC12V (Cannon 4pin connector) Tally Input:Contact Closure input Control System:Asynchronous System(TX/RX signal:RS422) Synchronous Signal:REF Input(GL Input:Tri Level SYNC) Camera Interface Connector:D-SUB 15pin Female DIMENSIONS CONNECTORS CONTROL CABLE A control cable (5m) is included in this unit as a standard accessory. 228.2 65 225 15 242 15 6.5 60 32