Download presentation
Published bySofia Marsh Modified over 10 years ago
1
An Introduction To Marine Steam Propulsion Plant [Source: US Navy]
3
Four Phases of Steam Cycle
Generation Expansion Condensation Feed
4
GENERATION (Boilers)
5
GENERATION Boiler Steam drum fuel is converted to heat
largest and heaviest part of steam plant heat is transferred via conduction to water in the metal tubes some of this water becomes steam Steam drum as steam is generated it collects in the upper portion of the boiler steam collecting in the steam drum is called saturated steam
7
GENERATION Super heater
saturated steam does not contain enough thermal energy to make the turbines operate efficiently uses heat from the burner section of the boiler to increase the temperature of the steam superheated steam is also dryer which helps prevent erosion of the turbine blades and main feed pumps
8
GENERATION Economizer improves efficiency in the steam plant
uses thermal energy that would go up the stack to preheat feedwater before the steam drum nest of tubes located between the generating tubes of the boiler and the stack
9
EXPANSION (Turbines)
10
EXPANSION Turbines High pressure/high temperature steam goes from the superheater outlet to the high pressure turbine of the main engine this is where expansion begins superheated steam expands in the turbine and is converted to mechanical energy to turn the rotor
11
EXPANSION energy conversion takes place in two steps in each stage of turbine blades first the steam passes through the nozzles which increase the steam’s velocity this kinetic energy is then converted into work by the turbine blades after steam leaves the HP turbine it still has thermal energy steam undergoes the same process in the LP turbine
14
CONDENSATION (Condenser, MCP, AEC)
15
CONDENSATION Main Condenser
large sealed container that serves as an indirect-type shell and tube heat exchanger cool seawater flows through thousands of internal tubes steam from the exhaust of the LP turbine flows over these tubes and heat is removed from the steam, condensing the steam in to a liquid (Condensate) The condensing action of the steam creates and maintains a vacuum in the condensers
17
CONDENSATION Main condensate pump
one or two stage centrifugal pump, electrically driven moves condensate from the hotwell through the main air ejector condenser to the deaerating feed tank pump is drawing a suction on the water in the hotwell lowest pressure in the system occurs here
19
CONDENSATION Air ejector condenser shell and tube heat exchanger
two functions removes latent heat from the auxiliary steam being discharged by the air ejector transfers heat from the steam to the condensate to preheat it before it enters the deaerating feed tank
20
FEED (DFT, MFBP, MFP)
21
FEED PHASE The Deaerating feed tank is the beginning of the feed phase
Direct type heat exchanger - three functions feed is heated by auxiliary steam and then falls to the lower section - causing the oxygen held in solution to be removed heats feed and maintains proper temperature of water storage tank for heated oxygen free feedwater
22
FEED PHASE Feedwater goes from deaerating tank to main feed boost pump(MFBP) MFBP one or two stage double suction centrifugal pump installed below the DFT discharges into the suction side of the main feed pump (MFP)
23
FEED PHASE MFP Large Multistage Centrifugal pumps (steam or electrically driven) delivers feedwater in sufficient amounts and develops enough pressure to force the water into the boiler against the pressure of the steam drum
25
MACHINERY PLANT LAYOUT
No two ships are exactly alike Machinery is arranged in various ways as space and weight permit Generally speaking Propulsion machinery is usually on two levels condensers and main reduction gear on lower level propulsion turbines and pinion gears are on upper level
26
MACHINERY PLANT LAYOUT
Low pressure turbine exhaust is directly above the condenser Boilers are on the lower and upper levels along the centerline of the ship === END ===