Automatic Synthesis of Microfluidic Large Scale Integration Chips from a Domain-Specific Language Jeffrey McDaniel, Christopher Curtis, Philip Brisk University of California, Riverside Biomedical Circuits and Systems Conference Rotterdam, Netherlands, November 1, 2013
2
2 The Future Of Chemistry Miniaturization + Automation Laboratory-on-Chip (LoC)
3
3 Applications Biochemical assays and immunoassays Clinical pathology Drug discovery and testing Rapid assay prototyping Testing new drugs (via lung-on-a-chip) Biochemical terror and hazard detection DNA extraction & sequencing
4
4 Design of Continuous Fluid-flow LoCs AutoCAD Draw each layer of the chip manually Akin to transistor-level design of ICs with manual wire routing Limited Automation Multi-layer soft lithography [Amin et al., ICCD 2009] [Minhass et al. CASES 2011 & 2012] [McDaniel et al. ASPDAC 2013] Capillary dielectrophoresis [Pfeiffer et al. TCAD 2006] [Hsieh and Ho, VLSI Design 2011]
5
Current input specification [Minhass et al. CASES 2012] 5 Sequencing Graphs
6
6
7
BioCoder Compiler High-Level Language for assay specification 7 Our Contributions
8
8 BioCoder Restricted BioCoder language
9
9 Example: Influenza Detection The thermocycling protocol applied to the device consists of 92 degrees C for 30s, and then 35 cycles of the following: 92 degrees C for 5s, 55 degrees C for 10s, and 72 degrees C for 20s, and finally 72 degrees C for 60s, for a total cycling time of 22 minutes. A portion of the PCR product (~60nl) is subsequently subjected to a restriction endonuclease digestion within the same device. The restriction digest reaction is performed at 37 degrees C for 10 min. [Pal et al., Lab-on-a-Chip 2005]
10
Example: Influenza Detection 10 [Pal et al., Lab-on-a-Chip 2005]
11
Example: Influenza Detection 11 [Pal et al., Lab-on-a-Chip 2005]
12
Example: Influenza Detection 12 Influenza Detection
13
Example: Influenza Detection [Pal et al., Lab-on-a-Chip 2005] 13
14
Example: Influenza Detection 14 [Pal et al., Lab-on-a-Chip 2005]
15
Example: Influenza Detection [Pal et al., Lab-on-a-Chip 2005] 15
16
16 Conclusion and Future Work BioCoder Compiler High-level language for assay specification Restricted BioCoder specific to LoC’s Interface to existing tool-chains Provides intuitive interface for biochemists Future Work Complete design automation tools Extend the restricted BioCoder