Working Safely Around FT-50 Sources
Frank Szoke OMNIFISSION Inc.
2
Fill Level Gauge filtec® FT-50
3
100mCi Am-241 filtec® source
4
100mCi source – side view
5
100mCi source – front view
6
Protection from Radiation Hazards
- Time » The less time spent near the source, the smaller the dose - Distance » Maximizing distance minimizes dose - Shielding » Intervening material can block radiation
7
FT-50 Bottle Radiation Bar
8
Emergency Procedures Secure a Safe Area Restrict Safe Area
- Minimum safe distance of 5 meters Restrict Safe Area - Easily observable barrier with warning signs - If possible, do not leave the area unattended Contact Supervisor - CNSC Interface Call Appropriate Emergency Personnel - Inform them of presence of gauges
9
Emergency Procedures Re-admittance to area requires
- Dose rate monitoring - Contamination monitoring The CNSC must be notified: - Within 48 hours of the incident - Within 24 hours if material is lost or stolen
10
Safety Overview Close the shutter when:
- When unit is down for extended periods - performing maintenance on line or detector - performing leak tests
11
Summary When working with radioactive material:
- Consider your time around material - Remember to stay at a safe working distance - DO NOT attempt to bypass any shielding - Wear any required protective clothing - Wear any required TLD or DRD monitors in the most appropriate place - Only work in designated areas - Clean work area after use - Keep an inventory of all radioisotopes - Know what to do in an emergency
Similar presentations