RdSAP principles
2
Concepts of RdSAP Dwelling Types Building Parts Dimensions Age Bands
Habitable Rooms
3
Dwelling Types Dwelling Type House Bungalow Flat Maisonette Park Home
Built Form Detached Semi-detached Mid-terrace End-terrace Enclosed mid-terrace Enclosed end-terrace
4
Building Parts For simplicity of data entry the dwelling is divided into ‘main dwelling’ and ‘extensions’ Extensions may not be extensions in the conventional sense of the word, so we describe them as ‘parts’
5
Building Parts A building part: has only one roof type
has only one floor type was entirely built in one age band
6
Building Parts
7
Building Parts 2 building parts (main + ext 1) 100mm insulation
suspended floor suspended floor Age band A (pre 1900) Age band A (pre 1900) 2 building parts (main + ext 1)
8
Building Parts 2 building parts (main + ext 1) 100mm insulation
suspended floor suspended floor Age band C ( ) Age band A (pre 1900) 2 building parts (main + ext 1)
9
Building Parts 2 building parts (main + ext 1) 100mm insulation
solid floor suspended floor Age band A (pre 1900) Age band A (pre 1900) 2 building parts (main + ext 1)
10
Building Parts 1 building parts (main only) 100mm insulation
Age bands – many things stem from age band. For example, suspended floor suspended floor Age band A (pre 1900) Age band A (pre 1900) 1 building parts (main only)
11
Dimensions Once the dwelling is divided into parts, each storey of each part is defined by 4 dimensions each
12
Dimensions Internal or external (but not both!) 4 components: Area
Storey Height Exposed Perimeter Party Wall
13
Dimensions: ‘Heated envelope’
Porches Include if heated by fixed heating devices Exclude if unheated and external (i.e. protruding from external wall) or thermally separated from dwelling
14
Dimensions: ‘Heated envelope’
Conservatories Include unless separated from dwelling by wall with exterior grade doors and windows Exclude if separated as above
15
Dimensions: ‘Heated envelope’
Store / utility rooms Exclude if only accessible from outside of the dwelling Include if directly accessible from the occupied part of the dwelling
16
Age Bands Age bands are key to RdSAP, as they are the basis of a variety of assumptions about the performance of the dwelling
17
Age Bands Record per part
England & Wales Scotland Northern Ireland Park Homes Pre 1900 before 1900 n/a Before 1983 2007 – 2011 2007 – 2013 2006 onwards 2012 onwards 2014 onwards A before 1900 B C D E F G H I J K L 2012 onwards Record per part Build NOT refurb date (unless uninhabitable before refurb) (Slightly different in devolved nations)
18
Age Bands Critical – software makes assumptions about thermal values based on age Seek information from: Occupier / agent Documentary evidence Property style Building regs-related features
19
Habitable rooms Habitable rooms are another peculiar RdSAP concept, and are used to make assumptions about the proportion of the home is that is a ‘living’ area, which informs how it is heated
20
Habitable rooms RdSAP needs a simple count
Always included in the count: Living rooms Sitting rooms Dining rooms Studies Bedrooms
21
Habitable rooms Always excluded from the count: Utility rooms
Bathrooms / WCs Cloakrooms Halls / Landings / Stairways En-suite
22
Habitable rooms: kitchen
Include if there is space for a table and 4 chairs Otherwise exclude
23
Habitable rooms: divisions
Open plan areas one room Rooms divided by a doorway where door temporarily removed - architrave present and hinge holes not filled in two rooms
24
Heated habitable rooms
RdSAP needs a second simple count A heated habitable room is a habitable room with a fixed heat emitter
25
Construction and insulation
How to enter walls, floors, roofs
26
Wall construction Construction types: Cavity Solid brick Timber framed
System built Sandstone Granite or whinstone Cob Park home wall (park home only)
27
Wall insulation Insulation types: As built Unknown Internal External
Filled cavity Filled cavity + internal Filled cavity + external
28
Wall insulation Wall and insulation thickness must also be measured
Around window reveals usually best place
29
Roof construction Flat Pitched, access Pitched, no access to loft
Pitched (thatch) Other dwelling above Same dwelling above Pitched, sloping
30
Roof insulation Position of insulation: Rafters Joists Unknown None
Flat roof insulation Sloping ceiling insulation Insulation thickness also recorded
31
Floor construction Suspended timber Suspended-not timber Solid
Separate entries required for main part and any extensions
32
Floor insulation Unknown As-built Retro-fitted
Insulation thickness if known
33
RdSAP Space Heating How to enter details of the heating and hot water system
34
RdSAP allows 2 main and 1 secondary heating system to be entered, if required
Main Heating 1 is the one which heats living area
35
Main Heating Systems Most common are: Boiler and radiators
Electric storage heaters
36
Boilers Typically a central boiler and a circuit of pipe work distributing hot water to a number of radiators Can be gas, oil , LPG or biomass fuelled Several types with widely differing efficiencies ‘Wet’ underfloor heating becoming more common
37
Room Heaters Gas fires Open fires Closed fires (stoves)
Usually secondary heating systems
38
Boiler Type Regular boiler Combination boiler
Condensing regular boiler Condensing combi boiler CPSU Back boiler Range cooker boiler Micro-CHP
39
Flue Type combinations
Open flue Open flue-fan assisted Balanced flue Fan assisted room sealed Balanced flue = room sealed. The pictures show the characteristic ‘double pipe’ of a balanced flue. Presence of a fan is more difficult to tell, you can sometimes hear it when the boiler is on. Typically fans are found in newer boilers.
40
Central Heating Pump Age
Unknown in most cases If known it can be entered into RdSAP Post 2012 notably better
41
Main Heating Controls Room thermostats Programmer TRVs
Time and temperature zone control Weather compensator Boiler energy manager
42
Types of Secondary Heating – gas fires
43
Rooms in Roof A special case and needs some description
44
Types A conversion of what would normally be a loft space, above the main part of the dwelling, or above any extensions. A house designed for occupation of the roof space such as a chalet bungalow, usually built with dormer or roof light windows
45
To be included in the RdSAP assessment:
It must be accessed via a fixed staircase The height of the common wall must be less than 1.8m for at least 50% of common wall (excluding gable ends and party walls)
46
RdSAP details In this section we will cover the details of recording the various energy-related property features in RdSAP
47
Terrain Type Urban Suburban Rural Used to determine ventilation
48
Windows / Glazing Key data items: Total glazed area
Proportion of multiple-glazed area Multiple-glazing type
49
Total Glazed Area Normal or typical More than typical
Less than typical Much more than typical Much less than typical Sun rooms (next slide) Typical for age and construction – so a detached house built in the 1960s can be expected to have large windows, so enter as ‘typical’ unless it has an unusual feature like a sunroom, or has additional and extensive retrofitted patio doors
50
Extended Glazing and Sunrooms
RdSAP definition of a conservatory: a structure with at least 75% its roof and at least 50% of its walls glazed Sunrooms can be entered in the extended glazing facility
51
Doors Total number of external doors includes doors to unheated corridors and any doors within the heat loss perimeter Double door = 2 doors Glass patio door = window Documentary evidence of insulated doors required
52
Draughtproofing Proportion of draughtproofed windows and doors is entered as a percentage Assumptions can be made based on window type if draughtproofing cannot be determined
53
Open fireplaces Number of open fireplaces within property recorded
Conventions apply
54
Low Energy Lighting Need to record:
Total number of fixed light fittings Total number of fixed low energy lighting fitted outlets Only fixed lighting is assessed LED and CFL are low energy ‘Low energy halogens’ are not
55
Ventilation Method Natural ventilation Mechanical, supply and extract*
Mechanical, extract only* *whole house systems, NOT single room extract fans Presence of air conditioning can also be recorded by ticking a box
56
Electricity Meters Meter type must be recorded Single rate meter
Mechanical dual rate meter (often ‘white meter’) Digital dual rate meter Other tariffs (18/24h) Smart meters not yet