© ABB University - 1 Revision C E x t e n d e d A u t o m a t i o n S y s t e m 8 0 0 x A Chapter 5 OPC Connectivity Course T314.

Similar presentations


Presentation on theme: "© ABB University - 1 Revision C E x t e n d e d A u t o m a t i o n S y s t e m 8 0 0 x A Chapter 5 OPC Connectivity Course T314."— Presentation transcript:

1 © ABB University - 1 Revision C E x t e n d e d A u t o m a t i o n S y s t e m 8 0 0 x A Chapter 5 OPC Connectivity Course T314

2 © ABB University - 2 Revision C Overview Objectives After this chapter you should be able to: Describe communication structure and data flow Set up OPC connectivity Verify communication (live data) Explain the Name Uploader Reference Documentation 3BSE035983Industrial IT 800xA – Control and I/O OPC Server for AC 800M – Configuration 3BSE041434Industrial IT 800xA - System System Guide – Technical Data 3BSE043732Industrial IT 800xA – Control and I/O Application Programming – Introduction and Design OPC Connectivity

3 © ABB University - 3 Revision C OPC Communication OPC Server Settings System 800xA Settings Check OPC Connectivity OPC Connectivity

4 © ABB University - 4 Revision C OPC Standard OPC Communication OPC stands for OLE for Process Control. OLE (Object Linking and Embedding) is a Microsoft technology for objects to interact with each other. OLE is based on COM or DCOM. While OLE was originally designed for office applications (e.g. Word, Excel). OPC technology is an extension of that protocol for industrial applications OPC is a group defined protocol for process control data communication. OPC Data Access for real time data OPC Historical Data Access for historical data OPC Alarm and Event for event data

5 © ABB University - 5 Revision C Structure and Data Flow OPC Communication Aspect Server Connectivity Server

6 © ABB University - 6 Revision C Basic Rules OPC Communication The OPC Server must be installed in the same physical node as the Connectivity Server. One OPC Server is allowed to subscribe to data from a maximum of 24 PM861 controllers, or the equivalent number of variables from other controller types. A maximum of three OPC Servers are allowed to subscribe to Data Access and/or Alarm and Event from one controller. Multiple OPC Clients can subscribe to data or event notifications from the same OPC Server. A third-party OPC Client should, if possible, be installed on the same PC as the OPC Server.

7 © ABB University - 7 Revision C Afw OPC Service model Afw OPC Service Service Group Service Provider Service Provider Service Provider Service Provider Client/Server Network redundant Connectivity Servers redundant Connectivity Servers 800xA Clients Aspect Directory AC 800M controllers Controller XXX OPC Communication

8 © ABB University - 8 Revision C OPC Service AC 800M controller OPC Server DA Data Access AE Alarm & Events Connectivity Server Aspect Server OPC Client: Service Structure Client/Server Network Control Network 1 Service Group for each CS or CS-pair Service Provider ex. CS1/2 Service Provider ex. CS2/2 Event Collector, Service 1 Service Group for each CS or CS-pair Service Provider ex. CS1/2 Service Provider ex. CS2/2 OpcDA Connector, Service 800xA Clients OPC Communication

9 © ABB University - 9 Revision C OPC Communication OPC Server Settings System 800xA Settings Check OPC Connectivity OPC Connectivity

10 © ABB University - 10 Revision C Setup DA and AE Access OPC Server Settings

11 © ABB University - 11 Revision C Load Configuration Automatically OPC Server Settings

12 © ABB University - 12 Revision C OPC Communication OPC Server Settings System 800xA Settings Check OPC Connectivity OPC Connectivity

13 © ABB University - 13 Revision C Check OPC Data Access Settings (1) System 800xA Settings

14 © ABB University - 14 Revision C Check OPC Data Access Settings (2) System 800xA Settings

15 © ABB University - 15 Revision C Check OPC Alarm and Event Settings (1) System 800xA Settings

16 © ABB University - 16 Revision C System 800xA Settings Check OPC Alarm and Event Settings (2)

17 © ABB University - 17 Revision C System 800xA Settings Check OPC Alarm and Event Settings (3)

18 © ABB University - 18 Revision C OPC Communication OPC Server Settings System 800xA Settings Check OPC Connectivity OPC Connectivity

19 © ABB University - 19 Revision C Check Control Object Properties Check OPC Connectivity

20 © ABB University - 20 Revision C Good OPC Connection Check OPC Connectivity

21 © ABB University - 21 Revision C Bad OPC Connection Check OPC Connectivity

22 © ABB University - 22 Revision C Check the System Services Check OPC Connectivity

23 © ABB University - 23 Revision C