ROUNDABOUT CHARACTERISTICS TTE 6815
2
DEFINITIONS TRAFFIC CIRCLE: u Any intersection designed around a central island ROUNDABOUT: u A traffic circle with certain prescribed characteristics
5
ROUNADBOUT BENEFITS n Community enhancement n Traffic Calming n Safety n Reduced delay at lower volumes n Improved left turn treatment n Complex intersections
6
CURRENT ISSUES n Ped/bicycle treatment n High capacity applications n Residential street applications n Visibility requirements n Design details n Cost of implementation
7
ROUNDABOUT CHARACTERISTICS n Yield on entry
8
ROUNDABOUT CHARACTERISTICS n Yield on entry
10
ROUNDABOUT CHARACTERISTICS n Entry deflection for speed control
11
ROUNDABOUT CHARACTERISTICS n Yield on entry n No internal control n Entry deflection for speed control Deflection Min Radius = 100 m Min Radius = 100 m
12
ROUNDABOUT CHARACTERISTICS n No parking on circulating roadway
13
ROUNDABOUT CHARACTERISTICS n No parking on circulating roadway
14
ROUNDABOUT CHARACTERISTICS n No pedestrians on center island
15
ROUNDABOUT CHARACTERISTICS n Counter clockwise circulation
16
ROUNDABOUT CHARACTERISTICS n Counter clockwise circulation
17
ROUNDABOUT CHARACTERISTICS n Counter clockwise circulation
18
ROUNDABOUT CHARACTERISTICS n Counter clockwise circulation
19
ROUNDABOUT CHARACTERISTICS n Must accommodate design vehicle
23
ROUNDABOUT CHARACTERISTICS n Splitter islands
24
ROUNDABOUT CHARACTERISTICS n Splitter islands
25
ROUNDABOUT CHARACTERISTICS n Splitter islands
26
ROUNDABOUT CHARACTERISTICS n Pedestrians cross one car length back from the entry point
27
ROUNDABOUT CHARACTERISTICS n Pedestrians cross one car length back from the entry point
28
ROUNDABOUT CHARACTERISTICS n Pedestrians cross one car length back from the entry point
29
ROUNDABOUT CHARACTERISTICS n Deflection by physical features
30
ROUNDABOUT CHARACTERISTICS n Deflection by physical features
31
ROUNDABOUT CHARACTERISTICS n Deflection by physical features
32
OTHER REQUIREMENTS n Easily identified in the road system. n Layout must be clearly visible and must encourage drivers to enter slowly. n Adequate lighting is necessary.
33
A SIMPLE YIELD CONTROLLED JUNCTION n Because a roundabout is a series of yield-controlled junctions, this provides a good place to start.
34
n Press F7 to see these graphics of the intersection layout.
35
TRAFFIC VOLUMES n 60 % EB n 40% NB n Start with … u 300 EB u 200 NB
36
FIRST SIDRA RUN n Set up the basic parameters and intersection configuration n Enter traffic volumes n Enter flow scale limit at 250% n Run SIDRA n Observe performance measures
37
VOLUME GROWTH FACTOR n 100% TO 250 % n Capacity reached at 242% u 726 vph EB u 484 vph NB u NB Delay = 42 sec/veh
38
VOLUME GROWTH FACTOR v/c Ratio
39
VOLUME GROWTH FACTOR v/c Ratio Delay
40
VOLUME GROWTH FACTOR Capacity
41
VOLUME GROWTH FACTOR Capacity Spare Capacity
42
n CAPACITY: 484 n V/C RATIO :.40 n DELAY: 41.7 s/v n STOP RATE: 2.7 n 95% BACK OF QUEUE: 26.1 veh
43
TRAFFIC VOLUMES n 60 % EB n 40% NB n Now Try… u 675 EB u 450 NB n About 85% v/c
44
SECOND SIDRA RUN n Enter new volumes n Disable flow scale n Run SIDRA n Observe performance measures
45
n NB Delay: 19.2 sec/veh MOVEMENT CAPACITY AND PERFORMANCE SUMMARY --------------------------------------------- Mov’t Arv Total Deg. Aver. Eff. 95% Flow Cap. Satn Delay Stop B.O.Q ---------------------------------------------- EBT 675 1800 0.375 0.0 0.00 0.0 --------------------------------------------- NBR 450 530 0.849* 19.2 1.97 15.5
46
NEXT... n Let’s make up a roundabout composed of four of these junctions n Entering Volume 450 vph n Circulating Volume 675 vph
48
HOW?... n Each LT is included in the circulating volume at 2 junctions n Each Thru movt is included at 1 junction n RT’s do not appear anywhere
49
SO... n 450 vph on each approach n 60% Left (270 vph) n 30% Thru (135 vph) n 10% Right (45 vph)
50
CIRCULATING VOLUME 270 x 2 = 540 135 x 1 =135 === Total675
53
THIRD SIDRA RUN n Set up the roundabout configuration n Enter new volumes n Run SIDRA n Compare the performance with a single YIELD junction
54
COMPARISON n YIELD V/C =.85 Del = 19.2 s/v n ROUNDABOUT V/C =.64 Del = 9.3 s/v
55
ROUNDABOUT GAP ACCEPTANCE PARAMETERS ------------------------- Turn Critical Follow Gap Up (s) Headway ------------------------- Left 4.43 2.49 Thru 4.43 2.49 Right 4.43 2.49 -------------------------
56
STOP & YIELD CONTROL GAP ACCEPTANCE PARAMETERS Crit. Fol.up Min. % Exit Flow Gap Hdway Deps Opposing Left turns : 7.0 3.40 1.0 50 Through : 6.5 3.30 1.0 50 Right turns: 5.5 2.60 1.0 50 Opposed turns from priority road: 5.5 2.60 1.0 0
57
FOURTH SIDRA RUN n Return to YIELD example n Change gap acceptance characteristics n Run SIDRA n Observe performance measures
58
YIELD control with roundabout gap acceptance parameters n V/C Ratio =.646 n Delay = 7.6 s/v
60
FIFTH SIDRA RUN n Change island diameter to 4 meters and rerun SIDRA n Change island diameter to 100 meters and rerun SIDRA n Compare performance measures
61
EFFECT OF CENTRAL ISLAND DIAMETER 4 METERS n C. G. = 4.72 n F.O.H = 2.65 n V/C =.696 n Del = 11.6 100 METERS 4.14 sec 2.32 sec.575 7.4 sec/veh